{"id":2122,"date":"2020-11-18T07:00:59","date_gmt":"2020-11-18T07:00:59","guid":{"rendered":"https:\/\/35.94.173.37\/blog\/?p=2122"},"modified":"2024-11-04T07:02:24","modified_gmt":"2024-11-04T07:02:24","slug":"how-to-use-anritsu-site-master-initial-setup-guide","status":"publish","type":"post","link":"https:\/\/www.apexwaves.com\/blog\/how-to-use-anritsu-site-master-initial-setup-guide\/","title":{"rendered":"How to Use Anritsu Site Master- Initial Setup Guide"},"content":{"rendered":"<p><strong>This guide will cover how-to setup Site Master: Measurement Type, Frequency, Amplitude, Markers, Limit Line, and DTF.<\/strong><\/p>\n<p><strong>Anritsu\u2019s<\/strong>\u00a0handheld cable, antenna, and spectrum analyzer family, known as the\u00a0<strong>Site Master<\/strong>\u00a0series is designed for engineer\u2019s in-field measurements.<br \/>\nThis brief, basic guide will review some measurement setups involving the following models:\u00a0<a href=\"https:\/\/www.apexwaves.com\/analyzers\/anritsu\/site-master\/S331E\"><strong>S331E<\/strong><\/a>,\u00a0<a href=\"https:\/\/www.apexwaves.com\/analyzers\/anritsu\/site-master\/S332E\"><strong>S332E<\/strong><\/a>,\u00a0<a href=\"https:\/\/www.apexwaves.com\/analyzers\/anritsu\/site-master\/S361E\"><strong>S361E,<\/strong>\u00a0<\/a>and\u00a0<a href=\"https:\/\/www.apexwaves.com\/analyzers\/anritsu\/site-master\/S362E\"><strong>S362E<\/strong><\/a>.<\/p>\n<p>&nbsp;<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-1330\" src=\"https:\/\/www.apexwaves.com\/blog\/wp-content\/uploads\/2020\/11\/Anritsu-SiteMaster.jpg\" sizes=\"auto, (max-width: 398px) 100vw, 398px\" srcset=\"https:\/\/www.apexwaves.com\/blog\/wp-content\/uploads\/2020\/11\/Anritsu-SiteMaster.jpg 398w, https:\/\/www.apexwaves.com\/blog\/wp-content\/uploads\/2020\/11\/Anritsu-SiteMaster-300x167.jpg 300w\" alt=\"\" width=\"398\" height=\"221\" \/><\/p>\n<p>Let\u2019s begin.<\/p>\n<p><strong>Step 1:<\/strong>\u00a0Power on the unit and push the\u00a0<strong>Menu<\/strong>\u00a0button and select one of the following via touchscreen. (These units have 8.5 inch TFT color displays).<\/p>\n<ul>\n<li>Cable-Antenna Analyzer<\/li>\n<li>Transmission Measurement<\/li>\n<li>Spectrum Analyzer<\/li>\n<li>Power Meter<\/li>\n<li>High Accuracy Power Meter<\/li>\n<li>Interface Analyzer<\/li>\n<li>Channel Scanner<\/li>\n<li>CW Signal Generator<br \/>\nNote:\u00a0This menu screen may be different based on the installed options.<\/li>\n<\/ul>\n<p><strong>Step 2:<\/strong>\u00a0Select your\u00a0<strong>Measurement<\/strong>\u00a0type by pushing the main menu button and choosing your measurement.<\/p>\n<p><strong>Step 3:<\/strong>\u00a0Setting the\u00a0<strong>Frequency<\/strong>: Push the\u00a0<strong>Freq\/Dist<\/strong>\u00a0menu button, push\u00a0<strong>Start Freq\u00a0<\/strong>and enter the data then do the same for\u00a0<strong>Stop Freq<\/strong>. Use the arrow keys, knob, and keypad.<\/p>\n<p><strong>Step 4:<\/strong>\u00a0Setting the\u00a0<strong>Amplitude<\/strong>: Push the\u00a0<strong>Amplitude<\/strong>\u00a0menu button, then the\u00a0<strong>Top<\/strong>\u00a0menu button and enter the data then do the same for\u00a0<strong>Bottom.\u00a0<\/strong>Use the arrow keys, knob, and keypad.<\/p>\n<p><strong>Step 5:<\/strong>\u00a0Turning on your\u00a0<strong>Markers<\/strong>:<strong>\u00a0<\/strong>\u00a0Push the\u00a0<strong>Marker<\/strong>\u00a0menu button and push the\u00a0<strong>Marker 1 2 3 4 5 6<\/strong>\u00a0sub-menu keys \u2013 select #1 via the touch screen. Then, using your arrow keys, knob and keypad move the marker, note the selected marker is shown in the top left corner of the Site Master\u2019s graph.<br \/>\nNote:\u00a0<strong>Delta Markers<\/strong>\u00a0are optional for all 6 markers \u2013 select the\u00a0<strong>Delta On\/Off<\/strong>\u00a0sub-menu to turn on the Delta Markers.<\/p>\n<p><strong>Step 6:<\/strong>\u00a0<strong>Peak\/Valley Auto Markers<\/strong>: If you are measuring Return Loss &amp; VSWR, you may want to use the Site Master\u2019s\u00a0<strong>Peak\/Valley Auto<\/strong>\u00a0features.\u00a0 These can automatically engage Marker 1 to peak, Marker 2 to valley. M1 &amp; M2 will be displayed in the Marker Table.\u00a0 To set this up push\u00a0<strong>Marker &gt; Peak\/Valley Auto<\/strong>\u00a0on your Anritsu Site Master.<\/p>\n<p><strong>Step 7:<\/strong>\u00a0Set up the\u00a0<strong>Single Limit Line<\/strong>:\u00a0<strong>Push Shift<\/strong>\u00a0&gt;\u00a0<strong>Limit<\/strong>\u00a0in order to view the Limit Menu. Then push\u00a0<strong>Limit On\/Off\u00a0<\/strong>to set the Site Master\u00a0<strong>Limit<\/strong>. Push\u00a0<strong>Single Limit<\/strong>, adjust the limit value numeric keypad, and push\u00a0<strong>Enter<\/strong>. Finally, push the\u00a0<strong>Limit Alarm<\/strong>\u00a0button to engage the alarm on or off.<\/p>\n<p><strong>Step 8:<\/strong>\u00a0Setting up the\u00a0<strong>DTF.<\/strong><\/p>\n<ul>\n<li>Push\u00a0<strong>Measurements\u2019<\/strong>\u00a0main menu button and choose the\u00a0<strong>DTF VSWR<\/strong>\u00a0or\u00a0<strong>DTF Return Loss<\/strong>\u00a0button.<\/li>\n<li>Push\u00a0<strong>Freq\/Dist<\/strong>\u00a0menu button.<\/li>\n<li>Select\u00a0<strong>Units<\/strong>\u00a0sub-menu button and choose\u00a0<strong>m<\/strong>\u00a0which shows the distance in meters OR\u00a0<strong>ft\u00a0<\/strong>which shows the distance in feet.<\/li>\n<li>Push DTF Aid to set the parameters using the touchscreen: set\u00a0<strong>Start Distance<\/strong>\u00a0and\u00a0<strong>Stop Distance<\/strong>\u00a0(which must be lower than Dmax).<\/li>\n<li>Enter the Site Master\u2019s\u00a0<strong>Start<\/strong>\u00a0&amp;\u00a0<strong>Stop Frequencies<\/strong>.<\/li>\n<li>Then choose the correct cable by pushing\u00a0<strong>Cable<\/strong>\u00a0then\u00a0<strong>Enter<\/strong>.<\/li>\n<li>Push\u00a0<strong>Continue<\/strong>. Push\u00a0<strong>Shift<\/strong>\u00a0&gt;\u00a0<strong>Calibrate<\/strong>.<\/li>\n<li>Set the\u00a0<strong>Markers<\/strong>,\u00a0<strong>Limit Lines<\/strong>\u00a0then\u00a0<strong>File<\/strong>\u00a0&amp; save.<\/li>\n<\/ul>\n<p>This concludes the basic setup guide of the\u00a0<strong>Anritsu Site Master\u2019s<\/strong>\u00a0Measurement Type, Frequency, Amplitude, Markers, Limit Line, and DTF.<\/p>\n<p>For\u00a0<strong>calibration instructions<\/strong>, check our post \u201c<strong>How to Calibrate Anritsu SiteMaster with OSL Calibration<\/strong>.\u201d<\/p>\n","protected":false},"excerpt":{"rendered":"<p>This guide will cover how-to setup Site Master: Measurement Type, Frequency, Amplitude, Markers, Limit Line, and DTF. Anritsu\u2019s\u00a0handheld cable, antenna, and spectrum analyzer family, known as the\u00a0Site Master\u00a0series is designed for engineer\u2019s in-field measurements. This brief, basic guide will review some measurement setups involving the following models:\u00a0S331E,\u00a0S332E,\u00a0S361E,\u00a0and\u00a0S362E. &nbsp; Let\u2019s begin. Step 1:\u00a0Power on the unit [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":2123,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[1],"tags":[58,59,279,853,869],"class_list":["post-2122","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-uncategorized","tag-anritsu","tag-anritsu-sitemaster","tag-how-to-use-anritsu-site-master","tag-sitemaster-analyzers","tag-spectrum-analyzers"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.apexwaves.com\/blog\/wp-json\/wp\/v2\/posts\/2122","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.apexwaves.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.apexwaves.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.apexwaves.com\/blog\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.apexwaves.com\/blog\/wp-json\/wp\/v2\/comments?post=2122"}],"version-history":[{"count":1,"href":"https:\/\/www.apexwaves.com\/blog\/wp-json\/wp\/v2\/posts\/2122\/revisions"}],"predecessor-version":[{"id":2124,"href":"https:\/\/www.apexwaves.com\/blog\/wp-json\/wp\/v2\/posts\/2122\/revisions\/2124"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.apexwaves.com\/blog\/wp-json\/wp\/v2\/media\/2123"}],"wp:attachment":[{"href":"https:\/\/www.apexwaves.com\/blog\/wp-json\/wp\/v2\/media?parent=2122"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.apexwaves.com\/blog\/wp-json\/wp\/v2\/categories?post=2122"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.apexwaves.com\/blog\/wp-json\/wp\/v2\/tags?post=2122"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}