{"id":2244,"date":"2020-01-16T11:12:39","date_gmt":"2020-01-16T11:12:39","guid":{"rendered":"https:\/\/35.94.173.37\/blog\/?p=2244"},"modified":"2024-11-04T11:14:52","modified_gmt":"2024-11-04T11:14:52","slug":"how-to-setup-and-power-the-ps-15-and-the-crio-9074","status":"publish","type":"post","link":"https:\/\/www.apexwaves.com\/blog\/how-to-setup-and-power-the-ps-15-and-the-crio-9074\/","title":{"rendered":"How to Setup and Power the PS-15 and the cRIO-9074"},"content":{"rendered":"<p>The\u00a0<strong>National Instruments CompactRIO Controller<\/strong>,\u00a0<strong><a href=\"https:\/\/www.apexwaves.com\/modular-systems\/national-instruments\/compactrio-controllers\/cRIO-9074\">cRIO-9074<\/a><\/strong>, is an embedded controller that is perfect for advanced monitoring and control. Since it is an electronic device, the\u00a0<strong>cRIO-9074<\/strong>\u00a0requires a DC power supply to work. The ideal power supply for this purpose is the\u00a0<strong><a href=\"https:\/\/www.apexwaves.com\/modular-systems\/national-instruments\/ni-power-supplies\/PS-15\">PS-15<\/a><\/strong>.<\/p>\n<p>The\u00a0<strong>PS-15<\/strong>\u00a0is an industrial power supply that is used to power\u00a0<strong><a href=\"https:\/\/www.apexwaves.com\/modular-systems\/national-instruments\/compactrio-controllers\/cRIO-9074\">CompactRIO<\/a>\u00a0<\/strong>systems,\u00a0<strong><a href=\"https:\/\/www.apexwaves.com\/modular-systems\/national-instruments\/compactdaq\">CompactDAQ<\/a><\/strong>\u00a0systems, and many more. This component takes in an input of 100 V<sub>AC\u00a0<\/sub>to 240 V<sub>AC<\/sub>\u00a0and supplies an output of 24 V<sub>DC<\/sub>, 5 A to the\u00a0<strong>cRIO-9074<\/strong>. However, for this setup to work, you need to carry out all the connections properly.<\/p>\n<p>This blog post covers the process of setting up and powering the\u00a0<strong>PS-15<\/strong>, and subsequently, the\u00a0<strong>cRIO-9074<\/strong>.<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p><strong>How to Power the PS-15<\/strong><\/p>\n<p>The first step in setting up the\u00a0<strong>cRIO-9074<\/strong>\u00a0is connecting the\u00a0<strong>PS-15<\/strong>\u00a0to an AC power source.<\/p>\n<p><strong>Input<\/strong><\/p>\n<p>The\u00a0<strong>PS-15<\/strong>\u00a0has three input terminals; the Live terminal labeled \u201cL,\u201d the Neutral terminal labeled \u201cN\u201d and the Protective Earth (PE) terminal labeled with the electrical grounding symbol. These terminals correspond with the live, neutral, and earth ports of a grounded electrical socket.<\/p>\n<p>To connect the\u00a0<strong>PS-15<\/strong>\u00a0to the power source, strip the ends of a standard 300 V (16 AWG) cable to expose the three wires inside. These wires are color-coded according to the terminals or ports to which they are to be connected; white for neutral, black for live, and green for earth. Note that the color coding for different cables may vary. The most common variations are blue (neutral), red\/brown (live), and green (earth); and black (neutral), red (live), and yellow\/green (earth).<\/p>\n<p>After exposing the wires, strip each wire by about 7 mm (0.275 in) to expose the copper inside. Connect the exposed ends of the three wires to the\u00a0<strong>PS-15<\/strong>\u00a0input terminals by lifting the terminal levers and inserting the wires into their corresponding input terminals. The live wire to the terminal labeled \u201cL\u201d, the neutral wire to the terminal labeled \u201cN\u201d, and the earth wire to the last terminal. Move the levers back down to the closed position and check that all your wires are tightly connected. If you are using stranded wire, ensure that all the strands are inside the terminal before you close it.<\/p>\n<p>Next, strip the other ends of the wires as described above. These ends go into the MAINS power source. Make sure that the power source is switched off before carrying out any connections. It is recommended that you first connect the wires to a plug before connecting them to the MAINS. Also, ensure that the wires from the neutral, live, and earth input terminals are connected to their corresponding neutral, live, and earth ports in the power source. After these connections, switching on the power source will turn on the\u00a0<strong>PS-15<\/strong>\u00a0and its indicator light. However, keep the power source off until you\u2019ve completed the connections in the\u00a0<strong>PS-15<\/strong>\u00a0output terminals.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-1138\" src=\"https:\/\/www.apexwaves.com\/blog\/wp-content\/uploads\/2020\/01\/Image-from-iOS-1.jpg\" sizes=\"auto, (max-width: 767px) 89vw, (max-width: 1000px) 54vw, (max-width: 1071px) 543px, 580px\" srcset=\"https:\/\/www.apexwaves.com\/blog\/wp-content\/uploads\/2020\/01\/Image-from-iOS-1.jpg 3024w, https:\/\/www.apexwaves.com\/blog\/wp-content\/uploads\/2020\/01\/Image-from-iOS-1-225x300.jpg 225w, https:\/\/www.apexwaves.com\/blog\/wp-content\/uploads\/2020\/01\/Image-from-iOS-1-768x1024.jpg 768w\" alt=\"\" width=\"3024\" height=\"4032\" \/><\/p>\n<p>&nbsp;<\/p>\n<p><strong>Output<\/strong><\/p>\n<p>The\u00a0<strong>PS-15<\/strong>\u00a0has four output terminals: two positives, labeled \u201c+\u201d and two negatives labeled \u201c-.\u201dTo get power out of the\u00a0<strong>PS-15<\/strong>, connect two wires with their ends exposed to the output terminals, one to a positive terminal and the other to a negative terminal. The other ends of these two wires are to be connected to the\u00a0<strong>cRIO-9074<\/strong>.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-1137\" src=\"https:\/\/www.apexwaves.com\/blog\/wp-content\/uploads\/2020\/01\/Image-from-iOS-2.jpg\" sizes=\"auto, (max-width: 767px) 89vw, (max-width: 1000px) 54vw, (max-width: 1071px) 543px, 580px\" srcset=\"https:\/\/www.apexwaves.com\/blog\/wp-content\/uploads\/2020\/01\/Image-from-iOS-2.jpg 3024w, https:\/\/www.apexwaves.com\/blog\/wp-content\/uploads\/2020\/01\/Image-from-iOS-2-225x300.jpg 225w, https:\/\/www.apexwaves.com\/blog\/wp-content\/uploads\/2020\/01\/Image-from-iOS-2-768x1024.jpg 768w\" alt=\"\" width=\"3024\" height=\"4032\" \/><\/p>\n<p>&nbsp;<\/p>\n<p><strong>How to Power CompactRIO<\/strong><\/p>\n<p>Fit an adapter (power controller) with four terminals into the power terminals of the CompactRIO Controller and screw it in. The adapter\u2019s four terminals are labeled \u201cV1,\u201d \u201cV2,\u201d \u201cC,\u201d and another \u201cC.\u201d Take the ends of the two wires coming from the output terminals of the\u00a0<strong>PS-15<\/strong>\u00a0and insert them into the terminals of the adapter that is fitted to the\u00a0<strong>cRIO-9074<\/strong>. The wire from the positive (+) terminal of the\u00a0<strong>PS-15<\/strong>\u00a0is connected to either of the terminals labeled \u201cV1\u201d or \u201cV2,\u201d while the wire from the negative (-) terminal is connected to either of the terminals labeled \u201cC.\u201d You may now switch on the power source to turn on the whole setup and you are good to go!<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-1139\" src=\"https:\/\/www.apexwaves.com\/blog\/wp-content\/uploads\/2020\/01\/Image-from-iOS.jpg\" alt=\"\" width=\"3024\" height=\"4032\" \/><\/p>\n<p>&nbsp;<\/p>\n<p><strong>IP Reset<\/strong><\/p>\n<p>For the\u00a0<strong>cRIO-9074<\/strong>\u00a0to function properly at MAX, you need to carry out an IP reset. To do this, flip the IP reset switch to the \u201cON\u201d position, then press and release the reset button. After this, flip the switch back and refresh the component MAX.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>The\u00a0National Instruments CompactRIO Controller,\u00a0cRIO-9074, is an embedded controller that is perfect for advanced monitoring and control. Since it is an electronic device, the\u00a0cRIO-9074\u00a0requires a DC power supply to work. The ideal power supply for this purpose is the\u00a0PS-15. The\u00a0PS-15\u00a0is an industrial power supply that is used to power\u00a0CompactRIO\u00a0systems,\u00a0CompactDAQ\u00a0systems, and many more. This component takes in [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":2245,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[8],"tags":[139,155,156,393,437,465,556],"class_list":["post-2244","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-national-instruments","tag-compactrio","tag-crio","tag-crio-9074","tag-national-instruments","tag-ni","tag-ni-ps-15","tag-power-supply"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.apexwaves.com\/blog\/wp-json\/wp\/v2\/posts\/2244","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.apexwaves.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.apexwaves.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.apexwaves.com\/blog\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.apexwaves.com\/blog\/wp-json\/wp\/v2\/comments?post=2244"}],"version-history":[{"count":1,"href":"https:\/\/www.apexwaves.com\/blog\/wp-json\/wp\/v2\/posts\/2244\/revisions"}],"predecessor-version":[{"id":2246,"href":"https:\/\/www.apexwaves.com\/blog\/wp-json\/wp\/v2\/posts\/2244\/revisions\/2246"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.apexwaves.com\/blog\/wp-json\/wp\/v2\/media\/2245"}],"wp:attachment":[{"href":"https:\/\/www.apexwaves.com\/blog\/wp-json\/wp\/v2\/media?parent=2244"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.apexwaves.com\/blog\/wp-json\/wp\/v2\/categories?post=2244"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.apexwaves.com\/blog\/wp-json\/wp\/v2\/tags?post=2244"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}