{"id":2493,"date":"2019-08-01T06:42:48","date_gmt":"2019-08-01T06:42:48","guid":{"rendered":"https:\/\/35.94.173.37\/blog\/?p=2493"},"modified":"2024-11-05T06:47:08","modified_gmt":"2024-11-05T06:47:08","slug":"national-instruments-scxi-part-5","status":"publish","type":"post","link":"https:\/\/www.apexwaves.com\/blog\/national-instruments-scxi-part-5\/","title":{"rendered":"National Instruments SCXI: Part 5"},"content":{"rendered":"<p>This is part 5 in our ongoing series about the\u00a0<a href=\"https:\/\/www.apexwaves.com\/modular-systems\/national-instruments\/scxi\/\"><strong>National Instruments SCXI platform<\/strong><\/a>. Part 5 will discuss the different types of\u00a0<strong>SCXI Chassis<\/strong>.<\/p>\n<p>&nbsp;<\/p>\n<p><strong>National Instruments SCXI<\/strong>\u00a0<strong>chassis<\/strong>\u00a0house, power, and control SCXI modules and conditioned signals. The unique SCXI chassis architecture includes the SCXIbus, which routes analog and digital signals and acts as the communication conduit between modules. Along with standard SCXI chassis,\u00a0<strong>NI<\/strong>\u00a0offers the versatility of combination chassis for SCXI and PXI\/CompactPCI modules. Within a single chassis, you get the choice of a wide variety of data acquisition, modular instrument, bus interface, image acquisition, and motion control modules, and the flexibility of SCXI signal conditioning.<\/p>\n<p>The\u00a0<strong>SCXI-1000DC<\/strong>\u00a0is a rugged, low-noise chassis that can hold as many as four SCXI modules. This chassis powers SCXI modules as well as handles all timing, trigger, and signal routing between your digitizer and SCXI modules. For larger systems or future expansion, you can also daisy chain up to eight\u00a0<a href=\"https:\/\/www.apexwaves.com\/modular-systems\/national-instruments\/scxi\/SCXI-1000DC\"><strong>SCXI-1000<\/strong><\/a><strong>\u00a0chassis<\/strong>\u00a0with one\u00a0<strong>E Series<\/strong>\u00a0digitizer for high-channel-count applications. You can power the\u00a0<strong>SCXI-1000DC<\/strong>\u00a0with any 9.5 to 16 VDC power supply or use the\u00a0<strong>SCXI-1382<\/strong>\u00a0battery pack. Other portable accessories and power supply\/float chargers are available as well.<\/p>\n<p>&nbsp;<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-645\" src=\"https:\/\/www.apexwaves.com\/blog\/wp-content\/uploads\/2019\/08\/SCXI-1000.jpg\" sizes=\"auto, (max-width: 700px) 100vw, 700px\" srcset=\"https:\/\/www.apexwaves.com\/blog\/wp-content\/uploads\/2019\/08\/SCXI-1000.jpg 700w, https:\/\/www.apexwaves.com\/blog\/wp-content\/uploads\/2019\/08\/SCXI-1000-300x233.jpg 300w\" alt=\"\" width=\"700\" height=\"544\" \/><\/p>\n<p>&nbsp;<\/p>\n<p>The\u00a0<strong>SCXI-1000<\/strong>\u00a0is a durable chassis with minimal noise and can hold a maximum of four SCXI modules. This chassis powers SCXI modules as well as handles all timing, trigger, and signal routing between your digitizer and SCXI modules. For bigger systems, or expansion later on, you can additionally daisy chain as many as eight\u00a0<strong>SCXI-1000 chassis<\/strong>\u00a0with one E Series digitizer for applications with many channels. The\u00a0<strong>SCXI-1000<\/strong>\u00a0offers seven different power options to match your country\u2019s power and can be reconfigured for use in other countries. Rack mounting and portable accessories are also available.<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-647\" src=\"https:\/\/www.apexwaves.com\/blog\/wp-content\/uploads\/2019\/08\/SCXI-1000-Obsolete.jpg\" sizes=\"auto, (max-width: 700px) 100vw, 700px\" srcset=\"https:\/\/www.apexwaves.com\/blog\/wp-content\/uploads\/2019\/08\/SCXI-1000-Obsolete.jpg 700w, https:\/\/www.apexwaves.com\/blog\/wp-content\/uploads\/2019\/08\/SCXI-1000-Obsolete-300x222.jpg 300w\" alt=\"\" width=\"700\" height=\"519\" \/><\/p>\n<p>&nbsp;<\/p>\n<p>The\u00a0<a href=\"https:\/\/www.apexwaves.com\/modular-systems\/national-instruments\/scxi\/SCXI-1001\"><strong>SCXI-1001<\/strong><\/a>\u00a0is a rugged, low-noise chassis that can hold up to 12 SCXI modules. This chassis powers SCXI modules as well as handles all timing, trigger, and signal routing between your digitizer and SCXI modules. For larger systems or future expansion, you can also daisy chain up to eight\u00a0<strong>SCXI-1001<\/strong>\u00a0<strong>chassis<\/strong>\u00a0with a single E Series digitizer for high-channel-count applications. The\u00a0<strong>SCXI-1000<\/strong>\u00a0offers seven different power options to match your country\u2019s power and can be reconfigured for use in other countries. Rack mounting and portable accessories are also available.<\/p>\n<p>&nbsp;<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-646\" src=\"https:\/\/www.apexwaves.com\/blog\/wp-content\/uploads\/2019\/08\/SCXI-1001.jpg\" sizes=\"auto, (max-width: 400px) 100vw, 400px\" srcset=\"https:\/\/www.apexwaves.com\/blog\/wp-content\/uploads\/2019\/08\/SCXI-1001.jpg 400w, https:\/\/www.apexwaves.com\/blog\/wp-content\/uploads\/2019\/08\/SCXI-1001-300x153.jpg 300w\" alt=\"\" width=\"400\" height=\"204\" \/><\/p>\n<p>&nbsp;<\/p>\n<p>The\u00a0<strong>National Instruments PXI-1052<\/strong>\u00a0is a 4-slot chassis with 8 slots for SCXI modules. The\u00a0<strong>NI PXI-1052<\/strong>\u00a0is suitable for data acquisition systems demanding multiplexing, signal conditioning, filtering, isolation, amplification, switching, etc. The\u00a0<strong>PXI-1052<\/strong>\u00a0offers quieter operation with acoustic emissions as low as 42 dBA, and a 0 to 55 \u00b0C temperature range. The\u00a0<strong>NI PXI-1052<\/strong>\u00a0provides a solution for PXI customers who require signal conditioning integrated into a single PXI chassis.<\/p>\n<p>The\u00a0<strong>National Instruments PXI-1050<\/strong>\u00a0is an 8-slot chassis with 4 slots for SCXI modules. The\u00a0<strong>NI PXI-1050<\/strong>\u00a0is well-suited for PXI measurement systems necessitating extra signal conditioning, including multiplexing, filtering, isolation, amplification, and switching. The PXI section can accept an embedded or remote controller and a wide variety of PXI modules, such as multifunction I\/O, digital I\/O, and modular instruments. The four SCXI slots allow you to integrate signal conditioning modules into your PXI system. The\u00a0<strong>PXI-1050<\/strong>\u00a0is ideal for applications that require high-accuracy measurements and signal conditioning in a single chassis. You can daisy-chain additional SCXI chassis to the\u00a0<strong>PXI-1050<\/strong>\u00a0to build high-channel-count applications.<\/p>\n<p>&nbsp;<\/p>\n<p>Part 6 in our\u00a0<strong>National Instruments SCXI<\/strong>\u00a0blog series is coming soon!<\/p>\n","protected":false},"excerpt":{"rendered":"<p>This is part 5 in our ongoing series about the\u00a0National Instruments SCXI platform. Part 5 will discuss the different types of\u00a0SCXI Chassis. &nbsp; National Instruments SCXI\u00a0chassis\u00a0house, power, and control SCXI modules and conditioned signals. The unique SCXI chassis architecture includes the SCXIbus, which routes analog and digital signals and acts as the communication conduit between [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":2494,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[8],"tags":[205,393,421,422,474,734,736],"class_list":["post-2493","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-national-instruments","tag-e-series","tag-national-instruments","tag-national-instruments-scxi","tag-national-instruments-scxi-chassis","tag-ni-scxi","tag-scxi-end-of-life","tag-scxi-obsolete"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.apexwaves.com\/blog\/wp-json\/wp\/v2\/posts\/2493","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.apexwaves.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.apexwaves.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.apexwaves.com\/blog\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.apexwaves.com\/blog\/wp-json\/wp\/v2\/comments?post=2493"}],"version-history":[{"count":1,"href":"https:\/\/www.apexwaves.com\/blog\/wp-json\/wp\/v2\/posts\/2493\/revisions"}],"predecessor-version":[{"id":2495,"href":"https:\/\/www.apexwaves.com\/blog\/wp-json\/wp\/v2\/posts\/2493\/revisions\/2495"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.apexwaves.com\/blog\/wp-json\/wp\/v2\/media\/2494"}],"wp:attachment":[{"href":"https:\/\/www.apexwaves.com\/blog\/wp-json\/wp\/v2\/media?parent=2493"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.apexwaves.com\/blog\/wp-json\/wp\/v2\/categories?post=2493"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.apexwaves.com\/blog\/wp-json\/wp\/v2\/tags?post=2493"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}