NI-9217
Modular Systems > National Instruments > C Series
Description: | NI-9217, 4-Channel, 400 S/s Aggregate, PT100 RTD, C Series Temperature Input Module |
Need an Official Quote?
Or speak to a sales representative for additional information:
National Instruments NI-9217 C Series Temperature Input Module
The NI‑9217 (Part Number: 779592-01) is a C Series Temperature Input Module. This resistance temperature detector (RTD) input module comes with four channels, 400 S/s aggregate sample rate, 0 Ω to 400 Ω, and PT100 RTD C. Users can design the NI 9217 RTD Module for two sample rate modes: high sample rate or high resolution. The NI 9217 will work with 3‑ and 4‑wire RTD estimations; this module consequently recognizes the sort of RTD (3‑ or 4‑wire) associated with the channel and arranges each channel for the fitting mode. The module gives per channel current excitation. This module highlights alignment and incorporates a channel‑to‑earth ground twofold disconnection hindrance for security, noise invulnerability, and a high basic mode voltage extend.
The NI 9217 RTD comes with CompactDAQ which is a versatile, rough information procurement platform that coordinates availability, data acquisition, and signal molding into I/O for straightforwardly interfacing to any sensor or signal. Utilizing CompactDAQ with LabVIEW, users can simply tweak how they get, break down, envision, and deal with estimation information. This module bolsters a low-control rest mode. Support for rest mode at the framework level relies upon the chassis that the module is connected to. Commonly, when a framework is in rest mode, users cannot communicate with the modules. In rest mode, the system consumes negligible power and may disperse less warmth than it does in typical mode. When it is utilized with CompactRIO, NI C Series Input Modules interface specifically to reconfigurable I/O (RIO) FPGA equipment to make elite embedded frameworks. The reconfigurable FPGA equipment inside CompactRIO gives an assortment of alternatives to custom planning, activating, synchronization, separating, and signal processing. The device can also be programmed using software packages like the NI-DAQmx driver software, LabWindows/CVI, Microsoft Visual C++, and so on.
The NI-9217 has recommended operating and storage temperature ranges of -40 °C to 70 °C and -40 °C to 85 °C respectively, non-condensing operating and storage humidity ranges of 10% RH to 90% RH and 5% RH to 95% RH, random and sinusoidal operating vibrations of 5 grms and 5 g respectively–at a frequency range of 10 to 500 Hz.
Associated Part Numbers: 192547-01, 192547-01L, 192547D-01, 192547E-01L, 779592-01
Model | NI-9217 |
---|---|
Manufacturer | National Instruments |
Part Number | 779592-01 |
Type | C Series Temperature Input Module |
Differential Analog Input Channels | 4 |
Maximum Sample Rate | 400 S/s |
Supported Sensors | PT100 RTD |
Front Connector | Screw Terminal |
Analog Input Isolation | 250 Vrms Ch-Earth Ground Isolation |
Warranty | Three Year Warranty |
NI-9217 Manual | User Manual and Maintenance Manual Available for Download |
Price | Contact a sales representative for a quote. |
National Instruments NI-9217 Frequently Asked Questions
Question: Which accessories can be used with the NI 9217 RTD Module?
Answer: The NI 9217 RTD Module can be used with the NI-9939 Backshell Connector Kit and the NI-9975 Screw-Terminal Block.
Question: How long is the NI 9217 calibration interval?
Answer: The NI 9217 calibration interval is one year.
Question: What type of wiring is the NI 9217 wiring?
Answer: The NI 9217 wiring is screw-terminal wiring with one wire for each screw terminal or two wires for each screw terminal utilizing a 2-wire ferrule.
Question: What kind of RTD measurements can the NI 9217 perform?
Answer: The NI 9217 RTD type is PT100.
NI-9217 PDF Manuals
ARCHIVED NI-9217 LETTER OF VOLATILITY.PDF
NI-9217 CALIBRATION PROCEDURE.PDF
NI-9217 GETTING STARTED GUIDE.PDF
NI-9217 LETTER OF VOLATILITY.PDF
Why Buy From Apex Waves:
"The business transaction was super easy and friendly."
"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"
"They were very helpful to get me the test equipment that I need."
NI-9217
1-800-915-6216
- Description
- Technical Specifications
- FAQ
- Manuals & PDFs
National Instruments NI-9217 C Series Temperature Input Module
The NI‑9217 (Part Number: 779592-01) is a C Series Temperature Input Module. This resistance temperature detector (RTD) input module comes with four channels, 400 S/s aggregate sample rate, 0 Ω to 400 Ω, and PT100 RTD C. Users can design the NI 9217 RTD Module for two sample rate modes: high sample rate or high resolution. The NI 9217 will work with 3‑ and 4‑wire RTD estimations; this module consequently recognizes the sort of RTD (3‑ or 4‑wire) associated with the channel and arranges each channel for the fitting mode. The module gives per channel current excitation. This module highlights alignment and incorporates a channel‑to‑earth ground twofold disconnection hindrance for security, noise invulnerability, and a high basic mode voltage extend.
The NI 9217 RTD comes with CompactDAQ which is a versatile, rough information procurement platform that coordinates availability, data acquisition, and signal molding into I/O for straightforwardly interfacing to any sensor or signal. Utilizing CompactDAQ with LabVIEW, users can simply tweak how they get, break down, envision, and deal with estimation information. This module bolsters a low-control rest mode. Support for rest mode at the framework level relies upon the chassis that the module is connected to. Commonly, when a framework is in rest mode, users cannot communicate with the modules. In rest mode, the system consumes negligible power and may disperse less warmth than it does in typical mode. When it is utilized with CompactRIO, NI C Series Input Modules interface specifically to reconfigurable I/O (RIO) FPGA equipment to make elite embedded frameworks. The reconfigurable FPGA equipment inside CompactRIO gives an assortment of alternatives to custom planning, activating, synchronization, separating, and signal processing. The device can also be programmed using software packages like the NI-DAQmx driver software, LabWindows/CVI, Microsoft Visual C++, and so on.
The NI-9217 has recommended operating and storage temperature ranges of -40 °C to 70 °C and -40 °C to 85 °C respectively, non-condensing operating and storage humidity ranges of 10% RH to 90% RH and 5% RH to 95% RH, random and sinusoidal operating vibrations of 5 grms and 5 g respectively–at a frequency range of 10 to 500 Hz.
Model | NI-9217 |
---|---|
Manufacturer | National Instruments |
Part Number | 779592-01 |
Type | C Series Temperature Input Module |
Differential Analog Input Channels | 4 |
Maximum Sample Rate | 400 S/s |
Supported Sensors | PT100 RTD |
Front Connector | Screw Terminal |
Analog Input Isolation | 250 Vrms Ch-Earth Ground Isolation |
Warranty | Three Year Warranty |
NI-9217 Manual | User Manual and Maintenance Manual Available for Download |
Price | Contact a sales representative for a quote. |
National Instruments NI-9217 Frequently Asked Questions
Question: Which accessories can be used with the NI 9217 RTD Module?
Answer: The NI 9217 RTD Module can be used with the NI-9939 Backshell Connector Kit and the NI-9975 Screw-Terminal Block.
Question: How long is the NI 9217 calibration interval?
Answer: The NI 9217 calibration interval is one year.
Question: What type of wiring is the NI 9217 wiring?
Answer: The NI 9217 wiring is screw-terminal wiring with one wire for each screw terminal or two wires for each screw terminal utilizing a 2-wire ferrule.
Question: What kind of RTD measurements can the NI 9217 perform?
Answer: The NI 9217 RTD type is PT100.
NI-9217 PDF Manuals & Diagrams
NI-9217 PDF Manuals
ARCHIVED NI-9217 LETTER OF VOLATILITY.PDF
NI-9217 CALIBRATION PROCEDURE.PDF
NI-9217 GETTING STARTED GUIDE.PDF
NI-9217 LETTER OF VOLATILITY.PDF
Why Buy From Apex Waves
"The business transaction was super easy and friendly."
"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"
"They were very helpful to get me the test equipment that I need."