USB-6211 National Instruments Multifunction I/O Device | Apex Waves | ImageUSB-6211 National Instruments Multifunction I/O Device | Apex Waves | ImageUSB-6211 NewUSB-6211 | Legacy, Refurbished and New Surplus
USB-6211 National Instruments Multifunction I/O Device | Apex Waves | Image
USB-6211 National Instruments Multifunction I/O Device | Apex Waves | Image
USB-6211 New
USB-6211 | Legacy, Refurbished and New Surplus

USB-6211

4.9/5 | 15 ratings

Modular Systems > National Instruments > USB Multifunction Devices

Part Number USB-6211
Manufacturer/Brand National Instruments
Description: USB-6211, 16 Bit Resolution, Onboard Amplifier, 250 kS/s Sample Rate, NI USB Multifunction I/O Device
In Stock | Ships in 5-10 Days
(expedited shipping options available)
Fast Quote
Quoted Price
Same Day Calibration Available
2-3 Year Warranty Included
Free Ground Shipping
  Get Pricing

Need an Official Quote?

 

Or speak to a sales representative for additional information:


National Instruments USB-6211 Multifunction I/O Device

The National Instruments USB-6211 (part numbers: 779676-01, 780104-01, and 196203-03) is a portable Multifunction I/O Device from the M Series. Boasting a wide range of connectivity options, the device features 16 single-ended analog input channels that are configurable as 8 differential channels. In addition, the NI USB-6211 is equipped with 2 analog output, 4 digital input, and 4 digital output channels. The maximum sampling rate of the channels is 250 kS/s, offering a high-resolution performance for a variety of test and measurement applications.

The difference between the part numbers for the NI USB-6211 Multifunction I/O Device is that part number 780104-01 is designed for Linux and Mac, while part number 196203-03 is the variation of the device with no enclosure (board only kit). Part number 779676-01 is the standard version of the device. The NI USB-6211 has 2 general purpose counters/timers that have 32 bits of resolution. These allow for a range of counter measurements- including edge counting, two-edge separation, period, semi-period, and pulse.

The front connectors of the NI USB-6211 are designed with screw terminals, which have a wiring of 16 AWG to 28 AWG. The internal base clocks of the I/O device range in frequency from either 80 MHz, 20 MHz, or 0.1 MHz. For external base clocks, the frequency ranges from 0 MHz to 20 MHz. When in a configured state, the USB port has an input voltage of 4.5 V to 5.25 V. The maximum load for the typical current is 400 mA at 4.5 V, while a suspend current of the USB-6211 has a maximum load of 260 μA (typically).

The physical specifications of the NI USB-6211 includes a 15 minute warm up time recommended for annual calibration. Designed for indoor use only, the device should be operated within a temperature range of 0 ºC to 45 ºC. When nonoperational, it should be kept within storage temperatures ranging from -20 ºC to 70 ºC. The USB-6211 Multifunction I/O Device, along with its connectors, measures 16.9 cm × 9.4 cm × 3.1 cm (6.65 in. × 3.70 in. × 1.20 in.) and weighs a total of 206 g (7.2 oz).

ModelUSB-6211
ManufacturerNational Instruments
Part Number779676-01
TypeMultifunction I/O Device
Analog Input Channels16 single-ended, 8 differential
Maximum Sample Rate250 kS/s
Analog Input Resolution16 bits
Front Connection TypeScrew Terminal
Dimensions6.65 in. × 3.70 in. × 1.20 in.
Weight7.2 oz.
WarrantyThree Year Warranty
USB-6211 ManualUser Manual and Maintenance Manual Available for Download
PriceContact a sales representative for a quote.

Associated part numbers for the USB-6211:

194710B-03, 194710C-03, 194710D-03L, 194710E-03L, 194710F-03L, 196203-03, 196203A-03L, 196203B-03L, 196203C-03L, 779676-01, 779803-01, 780104-01, 780127-01


Associated NSNs for the USB-6211:

7025-01-598-8895 (7025015988895)

National Instruments USB-6211 Frequently Asked Questions

 

Question: What is the timing accuracy and resolution of the USB-6211

Answer: The timing accuracy of the USB-6211 is 50 ppm of the sample rate, while the timing resolution is 50 ns.

 

Question: What is the input FIFO size of the USB-6211?

Answer: The input FIFO size is 4.095 samples.

 

Question: What is the sample rate for the USB-6211

Answer: The maximum sample rate for both single channels and multi-channels of the USB-6211 is 250 kS/s. The minimum is 0 S/s. 

  USB-6211 PDF Manuals


Why Buy From Apex Waves:

Apex Waves Youtube Video

"The business transaction was super easy and friendly."


"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"


"They were very helpful to get me the test equipment that I need."



Delivery:    
UPS, FedEX and DHL – Free Ground on all orders
Overnight, Next Day Air or Expedited shipping options available
International delivery available
Same day shipping for in-stock on location
Warranty: All of our products are covered by our Apex Waves Warranty.
3 Year Warranty - New Surplus Parts
2 Year Warranty - Refurbished Parts
Returns: No hassle return policy.
Dedicated customer service team.
Payment: Authorize.net Visa Master Card American Express BB&T Better Business Bureau Dun & Bradstreet
Quick Quotes: Receive Price & Availability Today!
Calibration: Ask About Our Tiered Calibration Levels
Option & Modules: Confirm Your Requirements or Versions
Repair: Cost & Lead Time Available Upon Request for Service
Repair Evaluation: $150
Share this page: Facebook Icon Twitter Icon LinkedIn Icon
Common Typos: YSB-6211, USH-6211, USB-6Q11, USB-6E11, USB-621Q

USB-6211



Modular Systems > National Instruments > USB Multifunction Devices

USB-6211
4.9/5 | 15 ratings

USB-6211, 16 Bit Resolution, Onboard Amplifier, 250 kS/s Sample Rate, NI USB Multifunction I/O Device

In Stock | Ships in 5-10 Days
(expedited shipping options available)
Same Day Calibration Available
2-3 Year Warranty Included
Free Ground Shipping
  Get Pricing

Call now for best pricing
1-800-915-6216

National Instruments USB-6211 Multifunction I/O Device

The National Instruments USB-6211 (part numbers: 779676-01, 780104-01, and 196203-03) is a portable Multifunction I/O Device from the M Series. Boasting a wide range of connectivity options, the device features 16 single-ended analog input channels that are configurable as 8 differential channels. In addition, the NI USB-6211 is equipped with 2 analog output, 4 digital input, and 4 digital output channels. The maximum sampling rate of the channels is 250 kS/s, offering a high-resolution performance for a variety of test and measurement applications.

The difference between the part numbers for the NI USB-6211 Multifunction I/O Device is that part number 780104-01 is designed for Linux and Mac, while part number 196203-03 is the variation of the device with no enclosure (board only kit). Part number 779676-01 is the standard version of the device. The NI USB-6211 has 2 general purpose counters/timers that have 32 bits of resolution. These allow for a range of counter measurements- including edge counting, two-edge separation, period, semi-period, and pulse.

The front connectors of the NI USB-6211 are designed with screw terminals, which have a wiring of 16 AWG to 28 AWG. The internal base clocks of the I/O device range in frequency from either 80 MHz, 20 MHz, or 0.1 MHz. For external base clocks, the frequency ranges from 0 MHz to 20 MHz. When in a configured state, the USB port has an input voltage of 4.5 V to 5.25 V. The maximum load for the typical current is 400 mA at 4.5 V, while a suspend current of the USB-6211 has a maximum load of 260 μA (typically).

The physical specifications of the NI USB-6211 includes a 15 minute warm up time recommended for annual calibration. Designed for indoor use only, the device should be operated within a temperature range of 0 ºC to 45 ºC. When nonoperational, it should be kept within storage temperatures ranging from -20 ºC to 70 ºC. The USB-6211 Multifunction I/O Device, along with its connectors, measures 16.9 cm × 9.4 cm × 3.1 cm (6.65 in. × 3.70 in. × 1.20 in.) and weighs a total of 206 g (7.2 oz).

ModelUSB-6211
ManufacturerNational Instruments
Part Number779676-01
TypeMultifunction I/O Device
Analog Input Channels16 single-ended, 8 differential
Maximum Sample Rate250 kS/s
Analog Input Resolution16 bits
Front Connection TypeScrew Terminal
Dimensions6.65 in. × 3.70 in. × 1.20 in.
Weight7.2 oz.
WarrantyThree Year Warranty
USB-6211 ManualUser Manual and Maintenance Manual Available for Download
PriceContact a sales representative for a quote.

National Instruments USB-6211 Frequently Asked Questions

 

Question: What is the timing accuracy and resolution of the USB-6211

Answer: The timing accuracy of the USB-6211 is 50 ppm of the sample rate, while the timing resolution is 50 ns.

 

Question: What is the input FIFO size of the USB-6211?

Answer: The input FIFO size is 4.095 samples.

 

Question: What is the sample rate for the USB-6211

Answer: The maximum sample rate for both single channels and multi-channels of the USB-6211 is 250 kS/s. The minimum is 0 S/s. 

Why Buy From Apex Waves

Apex Waves Youtube Video

"The business transaction was super easy and friendly."


"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"


"They were very helpful to get me the test equipment that I need."


Delivery: UPS, FedEX and DHL – Free FedEx Ground on all orders
Overnight, Next Day Air or Expedited shipping options available
International delivery available
Same day shipping for in-stock on location
Warranty: All of our products are covered by our Apex Waves Warranty.
3 Year Warranty - New Surplus Parts
2 Year Warranty - Refurbished Parts
Returns: No hassle return policy.
Dedicated customer service team.
Payment: Authorize.Net paypal visa card master card american express card BB&T Bank better business bureau
Quick Quotes: Receive Price & Availability Today!
Calibration: Ask About Our Tiered Calibration Levels
Option & Modules: Confirm Your Requirements or Versions
Repair: Cost & Lead Time Available Upon Request for Service
Repair Evaluation: $150