Description: PCI-1200, 8-Channel, 100 kS/s, Multifunction DAQ
In Stock | Ships Today
Fast Quote
Quoted Price
Same Day Calibration Available
2-3 Year Warranty Included
Free Ground Shipping
  Get Pricing

Need an Official Quote?

 

Or speak to a sales representative for additional information:


National Instruments PCI-1200 Multifunction DAQ

The National Instruments PCI-1200 (Part Numbers: 777386-01 and 777097-01) is a high-performance, low-cost multifunction digital, analog, and timing device designed for PCI bus computers. This device comes with eight Analog Input (AI) channels that can be configured as either four differential or eight single-ended inputs with a maximum sampling rate of 100 kS/s, a 12-bit successive-approximation type A/D converter (ADC), two 12-bit DACs with voltage outputs, 24 lines of TTL-compatible DIO, and three 16-bit timer/counters for timing I/O.

The PCI 1200 National Instruments is offered with NI-DAQ which has a comprehensive library of functions that can be called by the user from the ADE. These functions enable users to utilize the entire features of the Multifunction DAQ. National Instruments offers a broad range of optional products to use with this device, including: connector blocks, RTSI bus cables, 68-pin screw, and 50-pin shielded terminals, SCXI modules, etc. It is equipped with a 50-pin male I/O connector. The PCI 1200 Board is entirely software configurable and compliant with the PCI Local Bus Specs, Rev 2.2. All device resources are allocated automatically by the system itself. For this Multifunction DAQ, the allocations of resources include the interrupt level and base memory address. Thus, the user will not require any configuration steps after booting the system.

 After a software level reset or upon power-up, the National Instruments PCI-1200 DAQ Board is set to bipolar ±5 V Analog Input range and bipolar ±5 V Analog Output range. This model offers two channels of Analog Output voltage, allowing users to configure each analog output. Thus, users will be able to configure each one of the two AO output channels for either bipolar or unipolar output. The device has a power consumption value of 425 mA at +5 VDC. The NI device weighs 1.7 lb, and measures 6.9 x 4.2 in. in physical dimensions. It has a recommended operating temperature range of 0 to 50 °C, and a storage temperature range of.–55 to 150 °C.

PCI-1200 Obsolete Status has been announced by National Instruments, but it is still available for purchase and repairs by Apex Waves. 

Associated Part Numbers: 183094-01, 183094-02, 183094D-01, 183094F-01, 183094H-01, 183094J-02, 183094L-01, 183094R-01, 777097-01

ModelPCI-1200
ManufacturerNational Instruments
Part Numbers777386-01, 777097-01
TypeMultifunction I/O Device
Analog Inputs8 SE/4 DI
Resolution12 bits
Sampling Rate100 kS/s
Dimensions6.9 x 4.2 in.
Weight1.7 lb.
I/O Connectors50-pin male
WarrantyThree Year Warranty
PCI-1200 ManualUser Manual and Maintenance Manual Available for Download
PriceContact a sales representative for a quote.

National Instruments PCI-1200 Frequently Asked Questions

 

Question: What is the difference between the two part numbers for the National Instruments PCI-1200 DAQ Board?

 

Answer: The National Instruments PCI-1200 DAQ Board can be ordered for different operating systems: part number 777386-01 for Windows 2000/NT/9x or part number 777097-01 for Mac OS.

 

Question: What is the NI PCI-1200 driver?

 

Answer: The NI PCI-1200 driver is NI-DAQ.

 

Question: How do I calibrate the PCI 1200 National Instruments?

 

Answer: The PCI 1200 National Instruments can be self-calibrated with circuitry that adjusts for offset and gain errors.

 

Question: What is the value of the base clock on the PCI-1200 NI?

 

Answer: The base clock on the PCI-1200 NI is 2 MHz.

  PCI-1200 PDF Manuals


Why Buy From Apex Waves:

Apex Waves Youtube Video

"The business transaction was super easy and friendly."


"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"


"They were very helpful to get me the test equipment that I need."



Delivery:    
UPS, FedEX and DHL – Free Ground on all orders
Overnight, Next Day Air or Expedited shipping options available
International delivery available
Same day shipping for in-stock on location
Warranty: All of our products are covered by our Apex Waves Warranty.
3 Year Warranty - New Surplus Parts
2 Year Warranty - Refurbished Parts
Returns: No hassle return policy.
Dedicated customer service team.
Payment:
Quick Quotes: Receive Price & Availability Today!
Calibration: Ask About Our Tiered Calibration Levels
Option & Modules: Confirm Your Requirements or Versions
Repair: Cost & Lead Time Available Upon Request for Service
Repair Evaluation: $150
Share this page:
Common Typos: PFI-1200, PCL-1200, PCI-W200, PCI-12P0, PCI-120P

PCI-1200


PCI-1200

PCI-1200, 8-Channel, 100 kS/s, Multifunction DAQ

In Stock | Ships Today
Same Day Calibration Available
2-3 Year Warranty Included
Free Ground Shipping
  Get Pricing

Call now for best pricing
1-800-915-6216

National Instruments PCI-1200 Multifunction DAQ

The National Instruments PCI-1200 (Part Numbers: 777386-01 and 777097-01) is a high-performance, low-cost multifunction digital, analog, and timing device designed for PCI bus computers. This device comes with eight Analog Input (AI) channels that can be configured as either four differential or eight single-ended inputs with a maximum sampling rate of 100 kS/s, a 12-bit successive-approximation type A/D converter (ADC), two 12-bit DACs with voltage outputs, 24 lines of TTL-compatible DIO, and three 16-bit timer/counters for timing I/O.

The PCI 1200 National Instruments is offered with NI-DAQ which has a comprehensive library of functions that can be called by the user from the ADE. These functions enable users to utilize the entire features of the Multifunction DAQ. National Instruments offers a broad range of optional products to use with this device, including: connector blocks, RTSI bus cables, 68-pin screw, and 50-pin shielded terminals, SCXI modules, etc. It is equipped with a 50-pin male I/O connector. The PCI 1200 Board is entirely software configurable and compliant with the PCI Local Bus Specs, Rev 2.2. All device resources are allocated automatically by the system itself. For this Multifunction DAQ, the allocations of resources include the interrupt level and base memory address. Thus, the user will not require any configuration steps after booting the system.

 After a software level reset or upon power-up, the National Instruments PCI-1200 DAQ Board is set to bipolar ±5 V Analog Input range and bipolar ±5 V Analog Output range. This model offers two channels of Analog Output voltage, allowing users to configure each analog output. Thus, users will be able to configure each one of the two AO output channels for either bipolar or unipolar output. The device has a power consumption value of 425 mA at +5 VDC. The NI device weighs 1.7 lb, and measures 6.9 x 4.2 in. in physical dimensions. It has a recommended operating temperature range of 0 to 50 °C, and a storage temperature range of.–55 to 150 °C.

PCI-1200 Obsolete Status has been announced by National Instruments, but it is still available for purchase and repairs by Apex Waves. 

ModelPCI-1200
ManufacturerNational Instruments
Part Numbers777386-01, 777097-01
TypeMultifunction I/O Device
Analog Inputs8 SE/4 DI
Resolution12 bits
Sampling Rate100 kS/s
Dimensions6.9 x 4.2 in.
Weight1.7 lb.
I/O Connectors50-pin male
WarrantyThree Year Warranty
PCI-1200 ManualUser Manual and Maintenance Manual Available for Download
PriceContact a sales representative for a quote.

National Instruments PCI-1200 Frequently Asked Questions

 

Question: What is the difference between the two part numbers for the National Instruments PCI-1200 DAQ Board?

 

Answer: The National Instruments PCI-1200 DAQ Board can be ordered for different operating systems: part number 777386-01 for Windows 2000/NT/9x or part number 777097-01 for Mac OS.

 

Question: What is the NI PCI-1200 driver?

 

Answer: The NI PCI-1200 driver is NI-DAQ.

 

Question: How do I calibrate the PCI 1200 National Instruments?

 

Answer: The PCI 1200 National Instruments can be self-calibrated with circuitry that adjusts for offset and gain errors.

 

Question: What is the value of the base clock on the PCI-1200 NI?

 

Answer: The base clock on the PCI-1200 NI is 2 MHz.

Why Buy From Apex Waves

Apex Waves Youtube Video

"The business transaction was super easy and friendly."


"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"


"They were very helpful to get me the test equipment that I need."


Delivery: UPS, FedEX and DHL – Free FedEx Ground on all orders
Overnight, Next Day Air or Expedited shipping options available
International delivery available
Same day shipping for in-stock on location
Warranty: All of our products are covered by our Apex Waves Warranty.
3 Year Warranty - New Surplus Parts
2 Year Warranty - Refurbished Parts
Returns: No hassle return policy.
Dedicated customer service team.
Payment: Authorize.Net paypal visa card master card american express card BB&T Bank better business bureau
Quick Quotes: Receive Price & Availability Today!
Calibration: Ask About Our Tiered Calibration Levels
Option & Modules: Confirm Your Requirements or Versions
Repair: Cost & Lead Time Available Upon Request for Service
Repair Evaluation: $150
Share this page: facebook twitter linkedIn