PXIe-4330
Modular Systems > National Instruments > SC Express Series
Description: | PXIe-4330, 8-Channel, 24-Bit, PXI Strain/Bridge Input Module |
Need an Official Quote?
Or speak to a sales representative for additional information:
National Instruments PXIe-4330 PXI Strain/Bridge Input Module
The PXIe-4330 (Part Number: 781346-01, 194953D-02L) is a high-performance Strain/Bridge Input Module from National Instruments. The built-in ADC has the resolution of 24-bits. The NI PXIe-4330 Strain/Bridge Input Module offers eight analog input channels. The module makes use of the simultaneous mode of operation for the sampling of signals. The instrument offers exceptional throughput and high accuracy. It also incorporates synchronization capabilities, which makes it suitable for critical industrial requirements that need high accuracy. The PXIe-4330 Strain/Bridge Input Module incorporates digital filters implemented separately for each channel in use. They enable the user to reduce or remove the noise from the signal under test.
The PXIe-4330 module has a FIFO buffer size of 1,023 samples. The data transfers on this module are carried out through programmed I/O and direct memory access. The frequency sample rate of the device is 1 S/s to 100 S/s for the increment of 1 S/s. The sample rate for the 100 S/s increment is from 100 S/s to 25.6 kS/s. The CMRR value for NI PXIe-4330 Strain/Bridge Input Module is 85 dB.
The National Instruments PXIe-4330 module offers three different bridge completion modes: full, half, and quarter modes of operation. The user can select any of the modes per channel through software. It also offers software selectable shunt calibration per channel. The values offered for the calibration are 33.333 kΩ, 50 kΩ, and 100 kΩ. The maximum tolerance is 0.1%. It has the stability of 10 ppm/℃, which helps achieve the high measurement accuracy for NI PXIe-4330 Strain/Bridge Input Module.
Associated Part Numbers: 194953-02L, 194953C-02L, 194953D-02L, 781346-01, 786341-01, 786341-03, 786341-05, 787003-01
Model | PXIe-4330 |
---|---|
Part Number | 781346-01, 194953D-02L |
Manufacturer | National Instruments |
Type | PXI Strain/Bridge Input Module |
Differential Analog Input Channels | 8 |
Maximum Sample Rate | 25.6 kS/s |
Bridge Resistance | 1000 Ohm, 120 Ohm, 350 Ohm |
Dimensions | 6.3 x 3.9 in. |
Weight | 5.3 oz. |
Warranty | 2-3 Year Warranty |
PXIe-4330 Manual | User Manual and Maintenance Manual Available for Download |
Price | Contact a sales representative for a quote. |
National Instruments PXIe-4330 Frequently Asked Questions
Question: How long is the PXIe-4330 calibration interval?
Answer: The PXIe-4330 calibration interval is 1 year.
Question: How do I select the antialiasing filter on the NI PXIe-4330?
Answer: The antialiasing filter on the NI PXIe-4330 does not need to be selected; it automatically filters out specific noise frequencies.
Question: Which terminal block can be utilized with the PXIe-4330?
Answer: The TB-4330 connection block can be utilized with the PXIe-4330.
Question: Which bridge configurations are possible with the NI PXIe-4330?
Answer: The bridge configurations that are possible with the NI PXIe-4330 are Full Bridge, Half Bridge, and Quarter Bridge.
PXIe-4330 PDF Manuals
NI PXIE 4330 4331 LETTER OF VOLATILITY.PDF
NI PXIE 4330 4331 SPECIFICATIONS.PDF
NI PXIE 4330 4331 USER MANUAL.PDF
NI SC EXPRESS 4330 4331 INSTALLATION GUIDE AND TERMINAL BLOCK SPECIFICATIONS.PDF
PXIE 4330 4331 CALIBRATION PROCEDURE.PDF
Why Buy From Apex Waves:
"The business transaction was super easy and friendly."
"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"
"They were very helpful to get me the test equipment that I need."
PXIe-4330
1-800-915-6216
- Description
- Technical Specifications
- FAQ
- Manuals & PDFs
National Instruments PXIe-4330 PXI Strain/Bridge Input Module
The PXIe-4330 (Part Number: 781346-01, 194953D-02L) is a high-performance Strain/Bridge Input Module from National Instruments. The built-in ADC has the resolution of 24-bits. The NI PXIe-4330 Strain/Bridge Input Module offers eight analog input channels. The module makes use of the simultaneous mode of operation for the sampling of signals. The instrument offers exceptional throughput and high accuracy. It also incorporates synchronization capabilities, which makes it suitable for critical industrial requirements that need high accuracy. The PXIe-4330 Strain/Bridge Input Module incorporates digital filters implemented separately for each channel in use. They enable the user to reduce or remove the noise from the signal under test.
The PXIe-4330 module has a FIFO buffer size of 1,023 samples. The data transfers on this module are carried out through programmed I/O and direct memory access. The frequency sample rate of the device is 1 S/s to 100 S/s for the increment of 1 S/s. The sample rate for the 100 S/s increment is from 100 S/s to 25.6 kS/s. The CMRR value for NI PXIe-4330 Strain/Bridge Input Module is 85 dB.
The National Instruments PXIe-4330 module offers three different bridge completion modes: full, half, and quarter modes of operation. The user can select any of the modes per channel through software. It also offers software selectable shunt calibration per channel. The values offered for the calibration are 33.333 kΩ, 50 kΩ, and 100 kΩ. The maximum tolerance is 0.1%. It has the stability of 10 ppm/℃, which helps achieve the high measurement accuracy for NI PXIe-4330 Strain/Bridge Input Module.
Model | PXIe-4330 |
---|---|
Part Number | 781346-01, 194953D-02L |
Manufacturer | National Instruments |
Type | PXI Strain/Bridge Input Module |
Differential Analog Input Channels | 8 |
Maximum Sample Rate | 25.6 kS/s |
Bridge Resistance | 1000 Ohm, 120 Ohm, 350 Ohm |
Dimensions | 6.3 x 3.9 in. |
Weight | 5.3 oz. |
Warranty | 2-3 Year Warranty |
PXIe-4330 Manual | User Manual and Maintenance Manual Available for Download |
Price | Contact a sales representative for a quote. |
National Instruments PXIe-4330 Frequently Asked Questions
Question: How long is the PXIe-4330 calibration interval?
Answer: The PXIe-4330 calibration interval is 1 year.
Question: How do I select the antialiasing filter on the NI PXIe-4330?
Answer: The antialiasing filter on the NI PXIe-4330 does not need to be selected; it automatically filters out specific noise frequencies.
Question: Which terminal block can be utilized with the PXIe-4330?
Answer: The TB-4330 connection block can be utilized with the PXIe-4330.
Question: Which bridge configurations are possible with the NI PXIe-4330?
Answer: The bridge configurations that are possible with the NI PXIe-4330 are Full Bridge, Half Bridge, and Quarter Bridge.
PXIe-4330 PDF Manuals & Diagrams
PXIe-4330 PDF Manuals
NI PXIE 4330 4331 LETTER OF VOLATILITY.PDF
NI PXIE 4330 4331 SPECIFICATIONS.PDF
NI PXIE 4330 4331 USER MANUAL.PDF
NI SC EXPRESS 4330 4331 INSTALLATION GUIDE AND TERMINAL BLOCK SPECIFICATIONS.PDF
PXIE 4330 4331 CALIBRATION PROCEDURE.PDF
Why Buy From Apex Waves
"The business transaction was super easy and friendly."
"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"
"They were very helpful to get me the test equipment that I need."