Part Number USB-8473
Manufacturer/Brand National Instruments
Description USB-8473, 1-Port, CAN Interface Device
In Stock - Ships Today
In Stock | Ships 3-5 Days

Speak to a sales representative for pricing & lead time:


National Instruments USB-8473 CAN Interface Device

The USB-8473 (Part Number: 779792-01) is a fast controller area network (CAN) interface for creating applications with the NI-CAN controller. This model uses the Philips SJA1000 CAN controller and the TJA1041 CAN handset that offers useful features, such as listen-just mode, rest/wakeup mode, access to the mistake counter, and auto-gathering mode (resound). With the time stamp of the equipment, the user can record messages with time stamps in microseconds to remake network events. Numerous automotive applications request tight joining of CAN, LIN, simple, and advanced estimations. In applications, such as CAN gadget improvement and approval, the user must synchronize distinctive estimations to associate information. Users can program this synchronization in programming, yet OS inertness and clock float between the diverse installed oscillators present unsuitable postponements for certain car test applications.

NI offers the NI USB-8473 CAN Interface Device with a discretionary equipment synchronization highlight, with which the USB interfaces can share timing and activating signals with other USB-8473 interfaces, as well as information procurement, vision, and movement gadgets, to accomplish genuine equipment synchronization. Determinism is kept up between the trigger signal and the wanted reaction since timing and activating signals are taken care of in equipment. The host PC programming connects to recover the information once it is procured or to compose new information.

The CAN physical layer on this device interfaces the CAN controller to the physical transport wires. The USB 8473 National Instruments is accessible with fast and low-speed/blame tolerant physical layers. This CAN Interface Device has a locally available physical layer handsets and require no additional cables. The physical layers are internally fueled by a DC-to-DC converter.

ModelUSB-8473
ManufacturerNational Instruments
Part Number779792-01
TypeCAN Interface Device
Ports1
Transceiver TypePhilips TJA1041
Physical LayerHigh-Speed CAN
Maximum Transfer Rate1,000 kbit/s
WarrantyOne Year Warranty
USB-8473 ManualUser Manual and Maintenance Manual Available for Download
PriceContact a sales representative for a quote.

National Instruments USB-8473 Frequently Asked Questions

 

Question: What is the NI USB CAN 8473 driver called?

 

Answer: The NI USB CAN 8473 driver is NI-CAN.

 

Question: Does the USB-8473 NI have a hardware sync feature?

 

Answer: No, the USB-8473 NI does not have a hardware sync feature.

 

Question: Which type of connector does the USB 8473 National Instruments have?

 

Answer: The USB 8473 National Instruments has a standard 9-pin male D-SUB (DB9) connector.

USB-8473 Technical Specifications:


Manufacturer:National Instruments
Model:USB-8473
Part Number:779792-01
Type:CAN Interface Device
Repair Evaluation:$150

Why Buy From Apex Waves

Delivery: UPS, FedEX and DHL – Free UPS Ground on all orders
Overnight, Next Day Air or Expedited shipping options available
International delivery available
Same day shipping for in-stock on location
Warranty: All parts new, new surplus, used or reconditioned are covered by Apex Waves 1 Year Warranty
Returns: No hassle return policy.
Dedicated customer service team.
Payment:
Quick Quotes: Receive Price & Availability Today!
Calibration: Ask About Our Tiered Calibration Levels
Option & Modules: Confirm Your Requirements or Versions
Repair: Cost & Lead Time Available Upon Request for Service
Share this page:

USB-8473

USB-8473 National Instruments CAN Interface Device | Apex Waves | Image

Main Image
USB-8473 National Instruments CAN Interface Device | Apex Waves | Image

Secondary Image
USB-8473 National Instruments CAN Interface Device | Apex Waves - Wiring Diagram Image

Call now for best pricing
919 809 5227
Rate the USB-8473
rating
Rated 0/5 based on 0 ratings.

USB-8473, 1-Port, CAN Interface Device

Manufacturer:National Instruments
Model:USB-8473
Part Number:779792-01
Type:CAN Interface Device
Repair Evaluation:$150

National Instruments USB-8473 CAN Interface Device

The USB-8473 (Part Number: 779792-01) is a fast controller area network (CAN) interface for creating applications with the NI-CAN controller. This model uses the Philips SJA1000 CAN controller and the TJA1041 CAN handset that offers useful features, such as listen-just mode, rest/wakeup mode, access to the mistake counter, and auto-gathering mode (resound). With the time stamp of the equipment, the user can record messages with time stamps in microseconds to remake network events. Numerous automotive applications request tight joining of CAN, LIN, simple, and advanced estimations. In applications, such as CAN gadget improvement and approval, the user must synchronize distinctive estimations to associate information. Users can program this synchronization in programming, yet OS inertness and clock float between the diverse installed oscillators present unsuitable postponements for certain car test applications.

NI offers the NI USB-8473 CAN Interface Device with a discretionary equipment synchronization highlight, with which the USB interfaces can share timing and activating signals with other USB-8473 interfaces, as well as information procurement, vision, and movement gadgets, to accomplish genuine equipment synchronization. Determinism is kept up between the trigger signal and the wanted reaction since timing and activating signals are taken care of in equipment. The host PC programming connects to recover the information once it is procured or to compose new information.

The CAN physical layer on this device interfaces the CAN controller to the physical transport wires. The USB 8473 National Instruments is accessible with fast and low-speed/blame tolerant physical layers. This CAN Interface Device has a locally available physical layer handsets and require no additional cables. The physical layers are internally fueled by a DC-to-DC converter.

ModelUSB-8473
ManufacturerNational Instruments
Part Number779792-01
TypeCAN Interface Device
Ports1
Transceiver TypePhilips TJA1041
Physical LayerHigh-Speed CAN
Maximum Transfer Rate1,000 kbit/s
WarrantyOne Year Warranty
USB-8473 ManualUser Manual and Maintenance Manual Available for Download
PriceContact a sales representative for a quote.

National Instruments USB-8473 Frequently Asked Questions

 

Question: What is the NI USB CAN 8473 driver called?

 

Answer: The NI USB CAN 8473 driver is NI-CAN.

 

Question: Does the USB-8473 NI have a hardware sync feature?

 

Answer: No, the USB-8473 NI does not have a hardware sync feature.

 

Question: Which type of connector does the USB 8473 National Instruments have?

 

Answer: The USB 8473 National Instruments has a standard 9-pin male D-SUB (DB9) connector.

USB-8473 Technical Specifications:


Manufacturer:National Instruments
Model:USB-8473
Part Number:779792-01
Type:CAN Interface Device
Repair Evaluation:$150

Why Buy From Apex Waves

Delivery: UPS, FedEX and DHL – Free UPS Ground on all orders
Overnight, Next Day Air or Expedited shipping options available
International delivery available
Same day shipping for in-stock on location
Warranty: All parts new, new surplus, used or reconditioned are covered by Apex Waves 1 Year Warranty
Returns: No hassle return policy.
Dedicated customer service team.
Payment: Authorize.Net paypal visa card master card american express card BB&T Bank better business bureau
Quick Quotes: Receive Price & Availability Today!
Calibration: Ask About Our Tiered Calibration Levels
Option & Modules: Confirm Your Requirements or Versions
Repair: Cost & Lead Time Available Upon Request for Service
Share this page: facebook twitter linkedIn