USB-6351
Modular Systems > National Instruments > X Series
Description: | USB-6351, 16 AI, 2 AO, 24 DIO, Multifunction I/O Device |
Need an Official Quote?
Or speak to a sales representative for additional information:
National Instruments USB-6351 Multifunction I/O Device
The USB-6351 (Part Number: 781440-01) is a Multifunction I/O Device from National Instruments. This device has 8 differential and 16 single-ended analog input channels. The analog to digital resolution is about 16 bits. Each single-ended channel has 1.25 MS/s sample rate and 1.00 MS/s for multiple channels. This device has a timing resolution of 10 ns. The timing precision is 50 ppm. The NI USB-6351 uses input DC coupling. The AI channels have the highest working voltage of ±11 V. This voltage range is for both single and common modes.
The National Instruments USB-6351 Multifunction I/O Device has one analog trigger, which can perform in different analog modes, including the edge mode of operation for trigger requirements. It also includes analog window triggering. The analog trigger has the bandwidth -3 db. The NI USB-6351 X Series device also consists of 2 analog outputs with 16 bit DAC resolution. One channel has the highest update rate of 2.86 MS/s, while two channels have an update rate of 2.00 MS/s. The USB 6351 NI is structured with the NI‑STC3 timing and synchronization technology. These advanced techniques enable the module to provide enhanced timing functionality. This Multifunction I/O Device offers independent digital and analog timing engines. Furthermore, it is used for trigger-able measurement tasks.
The NI USB-6351 X Series DAQ is viable for a variety of applications. This Multifunction I/O Device comes with the classification application to manipulate basic data, which enables the user to control the procedures that involve the automation of the testing process. The module is equipped with configuration utility software and a NI-DAQmx driver. This software enables the module to simplify measurements and configuration. The NI USB-6351 has 24 digital lines that can be used as inputs/outputs. This Multifunction I/O Device is also featured with 32-bit counters, which are used for encoders and frequency, as well as PWM. It has a recommended warm-up time of 15 minutes, and should be calibrated at least once in 2 years.
The NI device weighs 2 oz, and measures 10.4 x 6.8 x 1.4 in. in physical dimensions. It has a recommended operating temperature range of 0 to 45 °C, a storage temperature range of -40 to 70 ºC.
Associated Part Numbers: 781440-01
Model | USB-6351 |
---|---|
Part Number | 781440-01 |
Type | Multifunction I/O Device |
Single-Ended Analog Input Channels | 16 |
Differential Analog Input Channels | 8 |
Maximum Sampling Rate | 1.25 MS/s |
Analog Input Resolution | 16 bits |
Dimensions | 10.4 x 6.8 x 1.4 in. |
Weight | 3 lb. 2 oz. |
Warranty | Three Year Warranty |
USB-6351 Manual | User Manual and Maintenance Manual Available for Download |
Price | Contact a sales representative for a quote. |
National Instruments USB-6351 Frequently Asked Questions
Question: What is the NI USB-6351 driver called?
Answer: The NI USB-6351 driver is NI-DAQmx.
Question: Which type of I/O connector does the NI USB-6351 X Series DAQ have?
Answer: The NI USB-6351 X Series DAQ has 64 screw terminals.
Question: How long is the USB-6351 X Series calibration interval?
Answer: The USB-6351 X Series calibration interval is 2 years.
Question: What is the maximum working voltage of the USB 6351 NI?
Answer: The maximum working voltage of the USB 6351 NI is 11 V, Measurement Category I channel-to-earth.
USB-6351 PDF Manuals
DAQ GETTING STARTED GUIDE FOR EXTERNALLY POWERED USB.PDF
DAQ GETTING STARTED GUIDE FOR PCI PCI EXPRESS.PDF
DAQ GETTING STARTED READ ME FIRST NI DAQMX AND DAQ DEVICE INSTALLATION GUIDE.PDF
DAQ MULTIFUNCTION I O MIO AND SIMULTANEOUS MULTIFUNCTION I O SMIO DEVICES CALIBRATION PROCEDURE.PDF
GUIDE D_INITIATION DAQ POUR LES PC3A9RIPHC3A9RIQUES USB C3A0 ALIMENTATION EXTERNE.PDF
GUIDE D_INITIATION DAQ POUR PCI PCI EXPRESS.PDF
LOCKING LID FOR USB SCREW TERMINAL DEVICES USER GUIDE.PDF
MULTIFUNCTION IO PRODUCT FLYER.PDF
NI 6351 DEVICE SPECIFICATIONS.PDF
USB 6341 43 51 53 61 63 LETTER OF VOLATILITY.PDF
USB X SERIES MOUNTING KIT INSTALLATION GUIDE.PDF
C3A0 LIRE EN PREMIER GUIDE DE28099INSTALLATION DE NI DAQMX ET DES PC3A9RIPHC3A9RIQUES DAQ.PDF
Why Buy From Apex Waves:
"The business transaction was super easy and friendly."
"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"
"They were very helpful to get me the test equipment that I need."
USB-6351
1-800-915-6216
- Description
- Technical Specifications
- FAQ
- Manuals & PDFs
National Instruments USB-6351 Multifunction I/O Device
The USB-6351 (Part Number: 781440-01) is a Multifunction I/O Device from National Instruments. This device has 8 differential and 16 single-ended analog input channels. The analog to digital resolution is about 16 bits. Each single-ended channel has 1.25 MS/s sample rate and 1.00 MS/s for multiple channels. This device has a timing resolution of 10 ns. The timing precision is 50 ppm. The NI USB-6351 uses input DC coupling. The AI channels have the highest working voltage of ±11 V. This voltage range is for both single and common modes.
The National Instruments USB-6351 Multifunction I/O Device has one analog trigger, which can perform in different analog modes, including the edge mode of operation for trigger requirements. It also includes analog window triggering. The analog trigger has the bandwidth -3 db. The NI USB-6351 X Series device also consists of 2 analog outputs with 16 bit DAC resolution. One channel has the highest update rate of 2.86 MS/s, while two channels have an update rate of 2.00 MS/s. The USB 6351 NI is structured with the NI‑STC3 timing and synchronization technology. These advanced techniques enable the module to provide enhanced timing functionality. This Multifunction I/O Device offers independent digital and analog timing engines. Furthermore, it is used for trigger-able measurement tasks.
The NI USB-6351 X Series DAQ is viable for a variety of applications. This Multifunction I/O Device comes with the classification application to manipulate basic data, which enables the user to control the procedures that involve the automation of the testing process. The module is equipped with configuration utility software and a NI-DAQmx driver. This software enables the module to simplify measurements and configuration. The NI USB-6351 has 24 digital lines that can be used as inputs/outputs. This Multifunction I/O Device is also featured with 32-bit counters, which are used for encoders and frequency, as well as PWM. It has a recommended warm-up time of 15 minutes, and should be calibrated at least once in 2 years.
The NI device weighs 2 oz, and measures 10.4 x 6.8 x 1.4 in. in physical dimensions. It has a recommended operating temperature range of 0 to 45 °C, a storage temperature range of -40 to 70 ºC.
Model | USB-6351 |
---|---|
Part Number | 781440-01 |
Type | Multifunction I/O Device |
Single-Ended Analog Input Channels | 16 |
Differential Analog Input Channels | 8 |
Maximum Sampling Rate | 1.25 MS/s |
Analog Input Resolution | 16 bits |
Dimensions | 10.4 x 6.8 x 1.4 in. |
Weight | 3 lb. 2 oz. |
Warranty | Three Year Warranty |
USB-6351 Manual | User Manual and Maintenance Manual Available for Download |
Price | Contact a sales representative for a quote. |
National Instruments USB-6351 Frequently Asked Questions
Question: What is the NI USB-6351 driver called?
Answer: The NI USB-6351 driver is NI-DAQmx.
Question: Which type of I/O connector does the NI USB-6351 X Series DAQ have?
Answer: The NI USB-6351 X Series DAQ has 64 screw terminals.
Question: How long is the USB-6351 X Series calibration interval?
Answer: The USB-6351 X Series calibration interval is 2 years.
Question: What is the maximum working voltage of the USB 6351 NI?
Answer: The maximum working voltage of the USB 6351 NI is 11 V, Measurement Category I channel-to-earth.
USB-6351 PDF Manuals & Diagrams
USB-6351 PDF Manuals
DAQ GETTING STARTED GUIDE FOR EXTERNALLY POWERED USB.PDF
DAQ GETTING STARTED GUIDE FOR PCI PCI EXPRESS.PDF
DAQ GETTING STARTED READ ME FIRST NI DAQMX AND DAQ DEVICE INSTALLATION GUIDE.PDF
DAQ MULTIFUNCTION I O MIO AND SIMULTANEOUS MULTIFUNCTION I O SMIO DEVICES CALIBRATION PROCEDURE.PDF
GUIDE D_INITIATION DAQ POUR LES PC3A9RIPHC3A9RIQUES USB C3A0 ALIMENTATION EXTERNE.PDF
GUIDE D_INITIATION DAQ POUR PCI PCI EXPRESS.PDF
LOCKING LID FOR USB SCREW TERMINAL DEVICES USER GUIDE.PDF
MULTIFUNCTION IO PRODUCT FLYER.PDF
NI 6351 DEVICE SPECIFICATIONS.PDF
USB 6341 43 51 53 61 63 LETTER OF VOLATILITY.PDF
USB X SERIES MOUNTING KIT INSTALLATION GUIDE.PDF
C3A0 LIRE EN PREMIER GUIDE DE28099INSTALLATION DE NI DAQMX ET DES PC3A9RIPHC3A9RIQUES DAQ.PDF
Why Buy From Apex Waves