Agilent 6000A Series Oscilloscopes

The HP Agilent 6000A Series of InfiniiVision Oscilloscopes have many triggering options, a high-definition display, 8 Mpts standard memory, a sample rate of 2 GSa/s or 4 GSa/s maximum, 100 MHz, 300 MHz, 500 MHz, and 1 GHz models, and either 2, 4, 2 analog + 16 digital, or 4 analog + 16 digital channels. These oscilloscopes allow the user to see intermittent occurrences that most oscilloscopes miss, while still being responsive to input controls. There is also an optional battery operation hardware configuration (Option BAT), which is useful for an advanced debug oscilloscope when AC power is not easily accessible.

The various triggering functions available on the 6000A Series include: pulse, edge, pattern, width, duration, V, serial bus, and sequence. There is a waveform update rate of 100,000 waveforms/second. The 6000A Series can be used with passive probes, such as the 10073C, 10074C, 10070C, 10076A, and 1165A. These probes are meant for use with any InfiniiVision Oscilloscope. Many active probes by Agilent are also compatible with the InfiniiVision Oscilloscopes, including the 1130A, 1141A, 1156A, and others. Certain probes do not need to be calibrated, but others do. The oscilloscopes in the 6000A Series can precisely calibrate its analog channels for some types of active probes.

Agilent 6000A Series Oscilloscopes

The HP Agilent 6000A Series of InfiniiVision Oscilloscopes have many triggering options, a high-definition display, 8 Mpts standard memory, a sample rate of 2 GSa/s or 4 GSa/s maximum, 100 MHz, 300 MHz, 500 MHz, and 1 GHz models, and either 2, 4, 2 analog + 16 digital, or 4 analog + 16 digital channels. These oscilloscopes allow the user to see intermittent occurrences that most oscilloscopes miss, while still being responsive to input controls. There is also an optional battery operation hardware configuration (Option BAT), which is useful for an advanced debug oscilloscope when AC power is not easily accessible.

The various triggering functions available on the 6000A Series include: pulse, edge, pattern, width, duration, V, serial bus, and sequence. There is a waveform update rate of 100,000 waveforms/second. The 6000A Series can be used with passive probes, such as the 10073C, 10074C, 10070C, 10076A, and 1165A. These probes are meant for use with any InfiniiVision Oscilloscope. Many active probes by Agilent are also compatible with the InfiniiVision Oscilloscopes, including the 1130A, 1141A, 1156A, and others. Certain probes do not need to be calibrated, but others do. The oscilloscopes in the 6000A Series can precisely calibrate its analog channels for some types of active probes.

No Products For This Series