AT-5102
Oscilloscopes > National Instruments > Oscilloscopes
Description: | AT-5102, 2-channel, 15 MHz, Digitizer |
(expedited shipping options available)
Need an Official Quote?
Or speak to a sales representative for additional information:
National Instruments AT-5102 Digitizer
The AT-5102 (Part Number: 777252-01) is an 8-bit digitizer. The manufacturer of the AT-5102 is National Instruments. The AT-5102 is a dual-channel digitizer with a sampling rate of 20 MS/s. The AT-5102 Digitizer is designed for the ISA bus. The NI AT-5102 can be used with NI-SCOPE driver software for configuration. The AT-5102 can be operated in software such as LabVIEW, Measurement Studio, and LabWindows/CVI. The Windows 2000/NT/XP operating systems are supported by the AT-5102 Digitizer.
The NI AT-5102 is specially designed for the rapid performance of automated systems. The AT-5102 provides high speed for data acquisition systems. The AT-5102 is featured with two analog channels with advanced properties. The bandwidth of an individual analog input channel is 15 MHz. A lower voltage level can be obtained through attenuation selector software. The voltage range can be varied from ±50 mV up to ±5 V. The signal measurement capabilities of the AT-5102 can also be enhanced with software-selectable AC or DC coupling techniques. The AT-5102 additionally contains two BNC connectors for analog input channels.
The NI AT-5102 utilizes an analog-to-digital converter. This Digitizer uses the 8-bit resolution and 20 MS/s sampling rate to digitize input signals. The sampling rate can be extended to different levels. The real time sampling rate of the AT-5102 varies from 20 MS/s to 1 kS/s. The random-interleaved sampling (RIS) technique is used to extend the significant sampling rate to the 1 GS/s level. The AT-5102 has a detained memory of 663,000 samples.
Model | AT-5102 |
---|---|
Manufacturer | National Instruments |
Part Number | 777252-01 |
Type | Digitizer |
ADC Resolution | 8 bits |
Input Channels | 2 |
Input Coupling | AC or DC |
Bandwidth | 15 MHz |
Memory | 663,000 samples/channel |
Input Range | ±50 mV to ±5 V |
Sampling Rate | 20 MS/s real-time and 1 GS/s random-interleaved sampling |
Warranty | 2-3 Year Warranty |
AT-5102 Manual | User Manual and Maintenance Manual Available for Download |
Price | Contact a sales representative for a quote. |
Associated part numbers for the AT-5102:
1.83442E-65, 183186-01, 183186A-01, 183186B-01, 183186C-01, 183186D-01, 183442F-01, 183442F-70, 777252-01, 777252-02
National Instruments AT-5102 Frequently Asked Questions
Question: Is the NI-DAQ 6.1 driver compatible with the AT-5102?
Answer: Yes, the NI-DAQ driver versions 5.0 and later are compatible with the AT-5102.
Question: Which oscilloscope probe can be used with the NI AT-5102?
Answer: The SP200B 10X-1X selectable oscilloscope probe can be used with the NI AT-5102.
Question: Does the NI AT-5102 have Real-Time System Integration triggers?
Answer: The NI AT-5102 does have Real-Time System Integration triggers.
AT-5102 PDF Manuals
ARCHIVED LABVIEW DATA ACQUISITION BASICS MANUAL.PDF
ARCHIVED NI 5102 CALIBRATION PROCEDURE.PDF
Driver Downloads for AT-5102
OS Compatibility:
Win XP 32-bit, Win 7 32-bit, Win 10 32-bit
Why Buy From Apex Waves:
"The business transaction was super easy and friendly."
"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"
"They were very helpful to get me the test equipment that I need."
AT-5102
Oscilloscopes > National Instruments > Oscilloscopes
1-800-915-6216
- Description
- Technical Specifications
- FAQ
- Manuals & PDFs
- Drivers
National Instruments AT-5102 Digitizer
The AT-5102 (Part Number: 777252-01) is an 8-bit digitizer. The manufacturer of the AT-5102 is National Instruments. The AT-5102 is a dual-channel digitizer with a sampling rate of 20 MS/s. The AT-5102 Digitizer is designed for the ISA bus. The NI AT-5102 can be used with NI-SCOPE driver software for configuration. The AT-5102 can be operated in software such as LabVIEW, Measurement Studio, and LabWindows/CVI. The Windows 2000/NT/XP operating systems are supported by the AT-5102 Digitizer.
The NI AT-5102 is specially designed for the rapid performance of automated systems. The AT-5102 provides high speed for data acquisition systems. The AT-5102 is featured with two analog channels with advanced properties. The bandwidth of an individual analog input channel is 15 MHz. A lower voltage level can be obtained through attenuation selector software. The voltage range can be varied from ±50 mV up to ±5 V. The signal measurement capabilities of the AT-5102 can also be enhanced with software-selectable AC or DC coupling techniques. The AT-5102 additionally contains two BNC connectors for analog input channels.
The NI AT-5102 utilizes an analog-to-digital converter. This Digitizer uses the 8-bit resolution and 20 MS/s sampling rate to digitize input signals. The sampling rate can be extended to different levels. The real time sampling rate of the AT-5102 varies from 20 MS/s to 1 kS/s. The random-interleaved sampling (RIS) technique is used to extend the significant sampling rate to the 1 GS/s level. The AT-5102 has a detained memory of 663,000 samples.
Model | AT-5102 |
---|---|
Manufacturer | National Instruments |
Part Number | 777252-01 |
Type | Digitizer |
ADC Resolution | 8 bits |
Input Channels | 2 |
Input Coupling | AC or DC |
Bandwidth | 15 MHz |
Memory | 663,000 samples/channel |
Input Range | ±50 mV to ±5 V |
Sampling Rate | 20 MS/s real-time and 1 GS/s random-interleaved sampling |
Warranty | 2-3 Year Warranty |
AT-5102 Manual | User Manual and Maintenance Manual Available for Download |
Price | Contact a sales representative for a quote. |
National Instruments AT-5102 Frequently Asked Questions
Question: Is the NI-DAQ 6.1 driver compatible with the AT-5102?
Answer: Yes, the NI-DAQ driver versions 5.0 and later are compatible with the AT-5102.
Question: Which oscilloscope probe can be used with the NI AT-5102?
Answer: The SP200B 10X-1X selectable oscilloscope probe can be used with the NI AT-5102.
Question: Does the NI AT-5102 have Real-Time System Integration triggers?
Answer: The NI AT-5102 does have Real-Time System Integration triggers.
AT-5102 PDF Manuals & Diagrams
AT-5102 PDF Manuals
ARCHIVED LABVIEW DATA ACQUISITION BASICS MANUAL.PDF
ARCHIVED NI 5102 CALIBRATION PROCEDURE.PDF
Why Buy From Apex Waves
"The business transaction was super easy and friendly."
"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"
"They were very helpful to get me the test equipment that I need."