Description: | AT-5102, 2-channel, 15 MHz, Digitizer |
(expedited shipping options available)
Need an Official Quote?
Or speak to a sales representative for additional information:
National Instruments AT-5102 Digitizer
The AT-5102 (Part Number: 777252-01) is an 8-bit digitizer. The manufacturer of the AT-5102 is National Instruments. The AT-5102 is a dual-channel digitizer with a sampling rate of 20 MS/s. The AT-5102 Digitizer is designed for the ISA bus. The NI AT-5102 can be used with NI-SCOPE driver software for configuration. The AT-5102 can be operated in software such as LabVIEW, Measurement Studio, and LabWindows/CVI. The Windows 2000/NT/XP operating systems are supported by the AT-5102 Digitizer.
The NI AT-5102 is specially designed for the rapid performance of automated systems. The AT-5102 provides high speed for data acquisition systems. The AT-5102 is featured with two analog channels with advanced properties. The bandwidth of an individual analog input channel is 15 MHz. A lower voltage level can be obtained through attenuation selector software. The voltage range can be varied from ±50 mV up to ±5 V. The signal measurement capabilities of the AT-5102 can also be enhanced with software-selectable AC or DC coupling techniques. The AT-5102 additionally contains two BNC connectors for analog input channels.
The NI AT-5102 utilizes an analog-to-digital converter. This Digitizer uses the 8-bit resolution and 20 MS/s sampling rate to digitize input signals. The sampling rate can be extended to different levels. The real time sampling rate of the AT-5102 varies from 20 MS/s to 1 kS/s. The random-interleaved sampling (RIS) technique is used to extend the significant sampling rate to the 1 GS/s level. The AT-5102 has a detained memory of 663,000 samples.
Associated Part Numbers: 777252-01
Model | AT-5102 |
---|---|
Manufacturer | National Instruments |
Part Number | 777252-01 |
Type | Digitizer |
ADC Resolution | 8 bits |
Input Channels | 2 |
Input Coupling | AC or DC |
Bandwidth | 15 MHz |
Memory | 663,000 samples/channel |
Input Range | ±50 mV to ±5 V |
Sampling Rate | 20 MS/s real-time and 1 GS/s random-interleaved sampling |
Warranty | One Year Warranty |
AT-5102 Manual | User Manual and Maintenance Manual Available for Download |
Price | Contact a sales representative for a quote. |
National Instruments AT-5102 Frequently Asked Questions
Question: Is the NI-DAQ 6.1 driver compatible with the AT-5102?
Answer: Yes, the NI-DAQ driver versions 5.0 and later are compatible with the AT-5102.
Question: Which oscilloscope probe can be used with the NI AT-5102?
Answer: The SP200B 10X-1X selectable oscilloscope probe can be used with the NI AT-5102.
Question: Does the NI AT-5102 have Real-Time System Integration triggers?
Answer: The NI AT-5102 does have Real-Time System Integration triggers.
AT-5102 PDF Manuals
ARCHIVED LABVIEW DATA ACQUISITION BASICS MANUAL.PDF
ARCHIVED NI 5102 CALIBRATION PROCEDURE.PDF
Driver Downloads for AT-5102
OS Compatibility:
Win XP 32-bit, Win 7 32-bit, Win 10 32-bit
Why Buy From Apex Waves:
AT-5102
1-800-915-6216
- Description
- Technical Specifications
- FAQ
- Manuals & PDFs
- Drivers
National Instruments AT-5102 Digitizer
The AT-5102 (Part Number: 777252-01) is an 8-bit digitizer. The manufacturer of the AT-5102 is National Instruments. The AT-5102 is a dual-channel digitizer with a sampling rate of 20 MS/s. The AT-5102 Digitizer is designed for the ISA bus. The NI AT-5102 can be used with NI-SCOPE driver software for configuration. The AT-5102 can be operated in software such as LabVIEW, Measurement Studio, and LabWindows/CVI. The Windows 2000/NT/XP operating systems are supported by the AT-5102 Digitizer.
The NI AT-5102 is specially designed for the rapid performance of automated systems. The AT-5102 provides high speed for data acquisition systems. The AT-5102 is featured with two analog channels with advanced properties. The bandwidth of an individual analog input channel is 15 MHz. A lower voltage level can be obtained through attenuation selector software. The voltage range can be varied from ±50 mV up to ±5 V. The signal measurement capabilities of the AT-5102 can also be enhanced with software-selectable AC or DC coupling techniques. The AT-5102 additionally contains two BNC connectors for analog input channels.
The NI AT-5102 utilizes an analog-to-digital converter. This Digitizer uses the 8-bit resolution and 20 MS/s sampling rate to digitize input signals. The sampling rate can be extended to different levels. The real time sampling rate of the AT-5102 varies from 20 MS/s to 1 kS/s. The random-interleaved sampling (RIS) technique is used to extend the significant sampling rate to the 1 GS/s level. The AT-5102 has a detained memory of 663,000 samples.
Model | AT-5102 |
---|---|
Manufacturer | National Instruments |
Part Number | 777252-01 |
Type | Digitizer |
ADC Resolution | 8 bits |
Input Channels | 2 |
Input Coupling | AC or DC |
Bandwidth | 15 MHz |
Memory | 663,000 samples/channel |
Input Range | ±50 mV to ±5 V |
Sampling Rate | 20 MS/s real-time and 1 GS/s random-interleaved sampling |
Warranty | One Year Warranty |
AT-5102 Manual | User Manual and Maintenance Manual Available for Download |
Price | Contact a sales representative for a quote. |
National Instruments AT-5102 Frequently Asked Questions
Question: Is the NI-DAQ 6.1 driver compatible with the AT-5102?
Answer: Yes, the NI-DAQ driver versions 5.0 and later are compatible with the AT-5102.
Question: Which oscilloscope probe can be used with the NI AT-5102?
Answer: The SP200B 10X-1X selectable oscilloscope probe can be used with the NI AT-5102.
Question: Does the NI AT-5102 have Real-Time System Integration triggers?
Answer: The NI AT-5102 does have Real-Time System Integration triggers.