Description: PCI-5153EX, 500 MHz, 8-Bit Oscilloscope Device
Request for Availablility
Fast Quote
Quoted Price
Same Day Calibration Available
2-3 Year Warranty Included
Free Ground Shipping
  Get Pricing

Need an Official Quote?

 

Or speak to a sales representative for additional information:


National Instruments PCI-5153EX Oscilloscope Device

The PCI-5153EX is an Oscilloscope Device from National Instruments. The PCI-5153EX is used to read and analyze analog waveforms. The device can analyze both time-domain and frequency-domain data. The PCI-5153EX device features driver software API. It includes many features like online data transfer and analysis. This model is an updated version of the PCI-5153 device. However, the PCI-5153EX device offers a higher-capacity FPGA. The PCI-5153EX device supports Hardware Accumulation Firmware (FW06), which increases hardware accumulation functionality.

The PCI-5153EX Oscilloscope Device has two analog input channels. These channels have BNC type connectors. The input impedance of the device is 50 Ω ± 2 Ω. The PCI-5153EX device can bear an input overload up to 7 Vrms with |Peaks| ≤ 10 V voltage. Both channels of the PCI-5153EX device are parallel and support simultaneous sampling. This device can sample data at a maximum speed of 2 GS/sec. The digital resolution of each analog channel is 8 bits. The maximum bandwidth of the PCI-5153EX device is 500 MHz.  The standard deep onboard memory size of the device is 8MB/Ch. However, the memory size is extendable to 256MB/Ch. The input range of the PCI-5153EX device is 100mV to 5V.

The PCI-5153EX Oscilloscope Device has two calibration modes: External Calibration and Self-calibration. External calibration is used to calibrate the onboard references. The onboard references are important for self-calibration. These references can also initiate external trigger levels. External calibration is required every two years. Self-calibration is controlled with a software command. Self-calibration corrects errors in different parameters of all input ranges. The external trigger input channel is not affected by self-calibration.

ModelPCI-5153ex
ManufacturerNational Instruments
TypeOscilloscope
Channels2
Bandwidth500 MHz
Sample Rate2 GS/s
Resolution8 bits
Dimensions8.5 x 0.8 x 5.1 in.
Weight16.97 oz.
WarrantyOne Year Warranty
PCI-5153ex ManualUser Manual and Maintenance Manual Available for Download
PriceContact a sales representative for a quote.

National Instruments PCI-5153EX Frequently Asked Questions

 

Question: What is the difference between the PCI-5153EX and the PCI-5153?

 

Answer: The PCI-5153EX has an FPGA with a larger capacity, which allows the oscilloscope to implement additional onboard signal processing.

 

Question: What are the software requirements for the NI PCI-5153EX?

 

Answer: The software requirements for the NI PCI-5153EX are NI-SCOPE 3.5.1 or later, 32-bit Windows OS, and PCI-5153EX supplemental software.

 

Question: When should the PCI-5153EX be externally calibrated?

 

Answer: The PCI-5153EX should be externally calibrated every two years.


Why Buy From Apex Waves:

Apex Waves Youtube Video


Delivery:    
UPS, FedEX and DHL – Free FedEx Ground on all orders
Overnight, Next Day Air or Expedited shipping options available
International delivery available
Same day shipping for in-stock on location
Warranty: All of our products are covered by our Apex Waves Warranty.
3 Year Warranty - New Surplus Parts
2 Year Warranty - Refurbished Parts
Returns: No hassle return policy.
Dedicated customer service team.
Payment:
Quick Quotes: Receive Price & Availability Today!
Calibration: Ask About Our Tiered Calibration Levels
Option & Modules: Confirm Your Requirements or Versions
Repair: Cost & Lead Time Available Upon Request for Service
Repair Evaluation: $150
Share this page:
Associated Part Numbers:
Common Typos: PCI-Y153EX, PCI-5Q53EX, PCI-5153FX, PCI-5153RX, PCI-5153ED

PCI-5153EX


PCI-5153EX

PCI-5153EX, 500 MHz, 8-Bit Oscilloscope Device

Request for Availablility
Same Day Calibration Available
2-3 Year Warranty Included
Free Ground Shipping
  Get Pricing

Call now for best pricing
1-800-915-6216

National Instruments PCI-5153EX Oscilloscope Device

The PCI-5153EX is an Oscilloscope Device from National Instruments. The PCI-5153EX is used to read and analyze analog waveforms. The device can analyze both time-domain and frequency-domain data. The PCI-5153EX device features driver software API. It includes many features like online data transfer and analysis. This model is an updated version of the PCI-5153 device. However, the PCI-5153EX device offers a higher-capacity FPGA. The PCI-5153EX device supports Hardware Accumulation Firmware (FW06), which increases hardware accumulation functionality.

The PCI-5153EX Oscilloscope Device has two analog input channels. These channels have BNC type connectors. The input impedance of the device is 50 Ω ± 2 Ω. The PCI-5153EX device can bear an input overload up to 7 Vrms with |Peaks| ≤ 10 V voltage. Both channels of the PCI-5153EX device are parallel and support simultaneous sampling. This device can sample data at a maximum speed of 2 GS/sec. The digital resolution of each analog channel is 8 bits. The maximum bandwidth of the PCI-5153EX device is 500 MHz.  The standard deep onboard memory size of the device is 8MB/Ch. However, the memory size is extendable to 256MB/Ch. The input range of the PCI-5153EX device is 100mV to 5V.

The PCI-5153EX Oscilloscope Device has two calibration modes: External Calibration and Self-calibration. External calibration is used to calibrate the onboard references. The onboard references are important for self-calibration. These references can also initiate external trigger levels. External calibration is required every two years. Self-calibration is controlled with a software command. Self-calibration corrects errors in different parameters of all input ranges. The external trigger input channel is not affected by self-calibration.

ModelPCI-5153ex
ManufacturerNational Instruments
TypeOscilloscope
Channels2
Bandwidth500 MHz
Sample Rate2 GS/s
Resolution8 bits
Dimensions8.5 x 0.8 x 5.1 in.
Weight16.97 oz.
WarrantyOne Year Warranty
PCI-5153ex ManualUser Manual and Maintenance Manual Available for Download
PriceContact a sales representative for a quote.

National Instruments PCI-5153EX Frequently Asked Questions

 

Question: What is the difference between the PCI-5153EX and the PCI-5153?

 

Answer: The PCI-5153EX has an FPGA with a larger capacity, which allows the oscilloscope to implement additional onboard signal processing.

 

Question: What are the software requirements for the NI PCI-5153EX?

 

Answer: The software requirements for the NI PCI-5153EX are NI-SCOPE 3.5.1 or later, 32-bit Windows OS, and PCI-5153EX supplemental software.

 

Question: When should the PCI-5153EX be externally calibrated?

 

Answer: The PCI-5153EX should be externally calibrated every two years.

Why Buy From Apex Waves

Apex Waves Youtube Video

Delivery: UPS, FedEX and DHL – Free FedEx Ground on all orders
Overnight, Next Day Air or Expedited shipping options available
International delivery available
Same day shipping for in-stock on location
Warranty: All of our products are covered by our Apex Waves Warranty.
3 Year Warranty - New Surplus Parts
2 Year Warranty - Refurbished Parts
Returns: No hassle return policy.
Dedicated customer service team.
Payment: Authorize.Net paypal visa card master card american express card BB&T Bank better business bureau
Quick Quotes: Receive Price & Availability Today!
Calibration: Ask About Our Tiered Calibration Levels
Option & Modules: Confirm Your Requirements or Versions
Repair: Cost & Lead Time Available Upon Request for Service
Repair Evaluation: $150
Share this page: facebook twitter linkedIn