PCI-5153EX
Oscilloscopes > National Instruments > Oscilloscopes
Description: | PCI-5153EX, 500 MHz, 8-Bit Oscilloscope Device |
Need an Official Quote?
Or speak to a sales representative for additional information:
National Instruments PCI-5153EX Oscilloscope Device
The PCI-5153EX is an Oscilloscope Device from National Instruments. The PCI-5153EX is used to read and analyze analog waveforms. The device can analyze both time-domain and frequency-domain data. The PCI-5153EX device features driver software API. It includes many features like online data transfer and analysis. This model is an updated version of the PCI-5153 device. However, the PCI-5153EX device offers a higher-capacity FPGA. The PCI-5153EX device supports Hardware Accumulation Firmware (FW06), which increases hardware accumulation functionality.
The PCI-5153EX Oscilloscope Device has two analog input channels. These channels have BNC type connectors. The input impedance of the device is 50 Ω ± 2 Ω. The PCI-5153EX device can bear an input overload up to 7 Vrms with |Peaks| ≤ 10 V voltage. Both channels of the PCI-5153EX device are parallel and support simultaneous sampling. This device can sample data at a maximum speed of 2 GS/sec. The digital resolution of each analog channel is 8 bits. The maximum bandwidth of the PCI-5153EX device is 500 MHz. The standard deep onboard memory size of the device is 8MB/Ch. However, the memory size is extendable to 256MB/Ch. The input range of the PCI-5153EX device is 100mV to 5V.
The PCI-5153EX Oscilloscope Device has two calibration modes: External Calibration and Self-calibration. External calibration is used to calibrate the onboard references. The onboard references are important for self-calibration. These references can also initiate external trigger levels. External calibration is required every two years. Self-calibration is controlled with a software command. Self-calibration corrects errors in different parameters of all input ranges. The external trigger input channel is not affected by self-calibration.
Model | PCI-5153ex |
---|---|
Manufacturer | National Instruments |
Type | Oscilloscope |
Channels | 2 |
Bandwidth | 500 MHz |
Sample Rate | 2 GS/s |
Resolution | 8 bits |
Dimensions | 8.5 x 0.8 x 5.1 in. |
Weight | 16.97 oz. |
Warranty | One Year Warranty |
PCI-5153ex Manual | User Manual and Maintenance Manual Available for Download |
Price | Contact a sales representative for a quote. |
National Instruments PCI-5153EX Frequently Asked Questions
Question: What is the difference between the PCI-5153EX and the PCI-5153?
Answer: The PCI-5153EX has an FPGA with a larger capacity, which allows the oscilloscope to implement additional onboard signal processing.
Question: What are the software requirements for the NI PCI-5153EX?
Answer: The software requirements for the NI PCI-5153EX are NI-SCOPE 3.5.1 or later, 32-bit Windows OS, and PCI-5153EX supplemental software.
Question: When should the PCI-5153EX be externally calibrated?
Answer: The PCI-5153EX should be externally calibrated every two years.
Why Buy From Apex Waves:
PCI-5153EX
1-800-915-6216
- Description
- Technical Specifications
- FAQ
National Instruments PCI-5153EX Oscilloscope Device
The PCI-5153EX is an Oscilloscope Device from National Instruments. The PCI-5153EX is used to read and analyze analog waveforms. The device can analyze both time-domain and frequency-domain data. The PCI-5153EX device features driver software API. It includes many features like online data transfer and analysis. This model is an updated version of the PCI-5153 device. However, the PCI-5153EX device offers a higher-capacity FPGA. The PCI-5153EX device supports Hardware Accumulation Firmware (FW06), which increases hardware accumulation functionality.
The PCI-5153EX Oscilloscope Device has two analog input channels. These channels have BNC type connectors. The input impedance of the device is 50 Ω ± 2 Ω. The PCI-5153EX device can bear an input overload up to 7 Vrms with |Peaks| ≤ 10 V voltage. Both channels of the PCI-5153EX device are parallel and support simultaneous sampling. This device can sample data at a maximum speed of 2 GS/sec. The digital resolution of each analog channel is 8 bits. The maximum bandwidth of the PCI-5153EX device is 500 MHz. The standard deep onboard memory size of the device is 8MB/Ch. However, the memory size is extendable to 256MB/Ch. The input range of the PCI-5153EX device is 100mV to 5V.
The PCI-5153EX Oscilloscope Device has two calibration modes: External Calibration and Self-calibration. External calibration is used to calibrate the onboard references. The onboard references are important for self-calibration. These references can also initiate external trigger levels. External calibration is required every two years. Self-calibration is controlled with a software command. Self-calibration corrects errors in different parameters of all input ranges. The external trigger input channel is not affected by self-calibration.
Model | PCI-5153ex |
---|---|
Manufacturer | National Instruments |
Type | Oscilloscope |
Channels | 2 |
Bandwidth | 500 MHz |
Sample Rate | 2 GS/s |
Resolution | 8 bits |
Dimensions | 8.5 x 0.8 x 5.1 in. |
Weight | 16.97 oz. |
Warranty | One Year Warranty |
PCI-5153ex Manual | User Manual and Maintenance Manual Available for Download |
Price | Contact a sales representative for a quote. |
National Instruments PCI-5153EX Frequently Asked Questions
Question: What is the difference between the PCI-5153EX and the PCI-5153?
Answer: The PCI-5153EX has an FPGA with a larger capacity, which allows the oscilloscope to implement additional onboard signal processing.
Question: What are the software requirements for the NI PCI-5153EX?
Answer: The software requirements for the NI PCI-5153EX are NI-SCOPE 3.5.1 or later, 32-bit Windows OS, and PCI-5153EX supplemental software.
Question: When should the PCI-5153EX be externally calibrated?
Answer: The PCI-5153EX should be externally calibrated every two years.
Why Buy From Apex Waves