National Instruments PXI-5105 PXI Oscilloscope
The NI PXI-5105 (Part Numbers: 195855B-02L, 779685-01, 779685-02, 779685-03) is a high-resolution digitizer and comes in three different models: the PXI-5105 16 MB digitizer (Part Number: 779685-01), the PXI-5105 128 MB digitizer (Part Number: 779685-02), and the PXI-5105 512 MB digitizer (Part Number: 779685-03). This PXI Oscilloscope comes equipped with eight 60 MS/s simultaneously sampled input channels with 12-bit resolution and 60 MHz transmission capacity in a 3U PXI gadget.
This model uses the National Instruments Synchronization and Memory Core (SMC) technology, so the user can consolidate various gadgets to develop 136 phase-coherent channels in one PXI chassis. The user can additionally synchronize a NI PXI 5105 with other digital and analog devices to make mixed signal test systems. This PXI Oscilloscope is perfect for an extensive variety of uses, such as ultrasonic nondestructive test (NDT), medical imaging, scientific research, military/aviation, and consumer devices.
The PXI 5105 Digitizer can be inserted into a PXI peripheral slot or a PXI Express Hybrid peripheral slot. This PXI Oscilloscope requires a PXI chassis, a PXI/CompactPCI chassis, or a PXI/SCXI combination chassis with a controller for operation. The PXI 5105 is run on the NI-SCOPE driver software is installed after the previous installation of an Application Development Environment–LabVIEW, LabWindows/CVI, Measurement Studio, Microsoft Visual C/C++, .NET (C# and VB.NET). This unit can be used with NI Measurement and Automation Explorer (MAX) to configure the Oscilloscope. MAX informs the different programs about which gadgets reside in the framework and how they are arranged (MAX is automatically installed with NI-SCOPE).
This model offers pre-trigger and post-trigger acquisition in single and multiple record mode, an internal 60 MHz clock or outside clock from 4 to 65 MHz, a phase bolt to PXI 10 MHz reference or outside reference from 1 to 20 MHz, timestamp-triggered events with 100 ps resolution, and >72 dBc of spurious-free dynamic range (SFDR). The PXI-5105 has 2 SMB jack connector types. The device has an operating temperature of 0 °C to 55 °C. Also, device calibration should be carried out at least once a year. Additional technical specs for the PXI-5105 can be found in the datasheets and manuals under the "Manuals & PDFs" tab.
Apex Waves will continue to Buy, Sell, and Repair EOL NI Hardware in perpetuity. While the PXI-5105 entered the NI Maintenance phase on December 30, 2022, it will remain available with Apex Waves. Request your quote today!
Model | PXI-5105 |
---|---|
Manufacturer | National Instruments |
Part Numbers | 779685-01, 779685-02, 779685-03, 195855B-02L |
HTS Code | 8471804000 |
Type | PXI Oscilloscope |
Onboard Memory Size | 16, 128, or 512 Mb/channel |
Input Channels | 8 |
Maximum Bandwidth | 60 MHz |
Dimensions | 8.5 × 0.8 × 5.1 in. |
Weight | 16.7 oz. |
Warranty | Three Year Warranty |
PXI-5105 Manual | User Manual and Maintenance Manual Available for Download |
Price | Contact a sales representative for a quote. |
Associated part numbers for the PXI-5105:
190353D-03, 190353F-03, 190353F-06, 190353G-03L, 190353G-06L, 190353K-06L, 192206B-01, 192206C-01, 192206D-01L, 192206E-01L, 192206F-01L, 192206G-01L, 195855A-01, 195855A-02, 195855A-03, 195855B-01, 195855B-01L, 195855B-02, 195855B-02L, 195855B-03, 195855B-03L, 195855C-01L, 195855C-02L, 195855C-03L, 195855D-01L, 195855D-02L, 195855D-03L, 195855E-01L, 195855E-02L, 195855E-03L, 195855F-01L, 195855F-02L, 195855F-03L, 195855G-01L, 195855G-02L, 195855G-03L, 200016A-01, 200017A-01, 779685-01, 779685-02, 779685-03
Associated NSNs for the PXI-5105:
5998-01-582-6894 (5998015826894), 5998-01-588-4540 (5998015884540)
National Instruments PXI-5105 Frequently Asked Questions
Question: What is the difference between the three part numbers for the PXI-5105?
Answer: The first part number for the PXI-5105, 779685-01, has 16 MB onboard memory size. The next part number, 779685-02, has 128 MB onboard memory size. Lastly, part number 779685-03 has 512 MB onboard memory size.
Question: What is the PXI-5105 driver called?
Answer: The PXI-5105 driver is NI-SCOPE 3.1 or later.
Question: How often should the PXI 5105 Digitizer be calibrated?
Answer: The PXI 5105 Digitizer should be calibrated every two years.
Question: Which type of front panel connectors are on the NI PXI 5105?
Answer: The NI PXI 5105 has SMB jack front panel connectors.
Question: Does the PXI-5105 support voltage offsets?
Answer: No, the PXI-5105 does not support voltage offsets.
PXI-5105 PDF Manuals
MAINTAIN FORCED AIR COOLING NOTE TO USERS.PDF
NI PXI PXIE PCI 5105 CALIBRATION PROCEDURE.PDF
NI PXI PXIE PCI 5105 GETTING STARTED GUIDE.PDF
OSCILLOSCOPE PROBE COMPENSATOR USER GUIDE.PDF
PCI PXI PXIE 5105 LETTER OF VOLATILITY.PDF
PXI-5105 Diagrams
Driver Downloads for PXI-5105
OS Compatibility:
Win XP 32-bit, Win 7 32-bit, Win 10 32-bit
Why Buy From Apex Waves:
"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"
"They were very helpful to get me the test equipment that I need."
PXI-5105
Oscilloscopes > National Instruments > Oscilloscopes
PXI-5105, 60 MHz, PXI Oscilloscope
1-800-915-6216
- Description
- Technical Specifications
- FAQ
- Manuals & PDFs
- Drivers
National Instruments PXI-5105 PXI Oscilloscope
The NI PXI-5105 (Part Numbers: 195855B-02L, 779685-01, 779685-02, 779685-03) is a high-resolution digitizer and comes in three different models: the PXI-5105 16 MB digitizer (Part Number: 779685-01), the PXI-5105 128 MB digitizer (Part Number: 779685-02), and the PXI-5105 512 MB digitizer (Part Number: 779685-03). This PXI Oscilloscope comes equipped with eight 60 MS/s simultaneously sampled input channels with 12-bit resolution and 60 MHz transmission capacity in a 3U PXI gadget.
This model uses the National Instruments Synchronization and Memory Core (SMC) technology, so the user can consolidate various gadgets to develop 136 phase-coherent channels in one PXI chassis. The user can additionally synchronize a NI PXI 5105 with other digital and analog devices to make mixed signal test systems. This PXI Oscilloscope is perfect for an extensive variety of uses, such as ultrasonic nondestructive test (NDT), medical imaging, scientific research, military/aviation, and consumer devices.
The PXI 5105 Digitizer can be inserted into a PXI peripheral slot or a PXI Express Hybrid peripheral slot. This PXI Oscilloscope requires a PXI chassis, a PXI/CompactPCI chassis, or a PXI/SCXI combination chassis with a controller for operation. The PXI 5105 is run on the NI-SCOPE driver software is installed after the previous installation of an Application Development Environment–LabVIEW, LabWindows/CVI, Measurement Studio, Microsoft Visual C/C++, .NET (C# and VB.NET). This unit can be used with NI Measurement and Automation Explorer (MAX) to configure the Oscilloscope. MAX informs the different programs about which gadgets reside in the framework and how they are arranged (MAX is automatically installed with NI-SCOPE).
This model offers pre-trigger and post-trigger acquisition in single and multiple record mode, an internal 60 MHz clock or outside clock from 4 to 65 MHz, a phase bolt to PXI 10 MHz reference or outside reference from 1 to 20 MHz, timestamp-triggered events with 100 ps resolution, and >72 dBc of spurious-free dynamic range (SFDR). The PXI-5105 has 2 SMB jack connector types. The device has an operating temperature of 0 °C to 55 °C. Also, device calibration should be carried out at least once a year. Additional technical specs for the PXI-5105 can be found in the datasheets and manuals under the "Manuals & PDFs" tab.
Apex Waves will continue to Buy, Sell, and Repair EOL NI Hardware in perpetuity. While the PXI-5105 entered the NI Maintenance phase on December 30, 2022, it will remain available with Apex Waves. Request your quote today!
Model | PXI-5105 |
---|---|
Manufacturer | National Instruments |
Part Numbers | 779685-01, 779685-02, 779685-03, 195855B-02L |
HTS Code | 8471804000 |
Type | PXI Oscilloscope |
Onboard Memory Size | 16, 128, or 512 Mb/channel |
Input Channels | 8 |
Maximum Bandwidth | 60 MHz |
Dimensions | 8.5 × 0.8 × 5.1 in. |
Weight | 16.7 oz. |
Warranty | Three Year Warranty |
PXI-5105 Manual | User Manual and Maintenance Manual Available for Download |
Price | Contact a sales representative for a quote. |
National Instruments PXI-5105 Frequently Asked Questions
Question: What is the difference between the three part numbers for the PXI-5105?
Answer: The first part number for the PXI-5105, 779685-01, has 16 MB onboard memory size. The next part number, 779685-02, has 128 MB onboard memory size. Lastly, part number 779685-03 has 512 MB onboard memory size.
Question: What is the PXI-5105 driver called?
Answer: The PXI-5105 driver is NI-SCOPE 3.1 or later.
Question: How often should the PXI 5105 Digitizer be calibrated?
Answer: The PXI 5105 Digitizer should be calibrated every two years.
Question: Which type of front panel connectors are on the NI PXI 5105?
Answer: The NI PXI 5105 has SMB jack front panel connectors.
Question: Does the PXI-5105 support voltage offsets?
Answer: No, the PXI-5105 does not support voltage offsets.
PXI-5105 PDF Manuals & Diagrams
PXI-5105 PDF Manuals
MAINTAIN FORCED AIR COOLING NOTE TO USERS.PDF
NI PXI PXIE PCI 5105 CALIBRATION PROCEDURE.PDF
NI PXI PXIE PCI 5105 GETTING STARTED GUIDE.PDF
OSCILLOSCOPE PROBE COMPENSATOR USER GUIDE.PDF