PXI-5112
Oscilloscopes > National Instruments > Oscilloscopes
Description: | PXI-5112, 2-Channel, PXI Digitizer |
Need an Official Quote?
Or speak to a sales representative for pricing & lead time:
National Instruments PXI-5112 PXI Digitizer
The NI PXI-5112 PXI Digitizer highlights profound onboard acquisition memory, wide analog bandwidth, and a substantial analog input range in a low-cost model. This model offers two part numbers: 777758-01 with 16 MB/channel and 777756-01 with 32 MB/channel. Since the NI PXI-5112 Digitizer depends on the rapid PCI bus, acquiring and processing expansive waveforms is considerably speedier than with equivalent GPIB-based instruments. Because of this enhanced transfer rate, the user can take estimations speedier and diminish general test time. The NI PXI-5112 has two analog input channels that acknowledge signals going from ±0.025 V to ±25 V, variable in 10 percent steps. Each channel highlights programmable DC offset up to 20 times the input range, depending on the range selected. Accessible AC coupling or DC offset expands the dynamic range of signals that the user can quantify. The user can also force a 20 MHz hardware bandwidth limit for each channel to expel undesirable high-recurrence noise from estimations.
The NI PXI-5112 Digitizer is outfitted with the NI-TIO ASIC, a state-of-the-art counter and timing I/O ASIC created by National Instruments. The NI-TIO digitizer timing motor gives time stamping of records to 2 ns precision for real-time sampling and 100 ps exactness for random-interleaved testing (RIS). Time stamping likewise works in different record procurement mode. With quick rearm times, the user can timestamp activated occasions for up to 130 days with 2 ns precision continuously inspecting mode.
Both analog channels have their own 100 MS/s, 8-bit analog-to-digital converter (ADC), so the user can acquire information at the same time on each channel, at rates from 100 MS/s to 1 S/s. With the NI PXI-5112 high-exactness timing hardware, the user can test repetitive signals at rates up to 2.5 GS/s.
Model | PXI-5112 (777758-01, 777756-01) |
---|---|
Manufacturer | National Instruments |
Type | PXI Oscilloscope |
Onboard Sample Memory | 16 or 32 MB/channel (based on part # purchased) |
Resolution | 8 bits |
Channels | 2 |
Sample Rate | 100 MS/s |
Dimensions | 3.9 x 6.3 in. |
Warranty | One Year Warranty |
PXI-5112 Manual | User Manual and Maintenance Manual Available for Download |
Price | Contact a sales representative for a quote. |
National Instruments PXI-5112 Frequently Asked Questions
Question: Where can I find the manual for the NI PXI-5112?
Answer: The PXI-5112 manual is available for download on the apexwaves.com website.
Question: Why does the PXI-5112 have two part numbers? What are the differences between them?
Answer: The PXI-5112 has two onboard sample memory options, each with a different part number. Part number 777758-01 has 16 MB/channel and part number 777756-01 has 32 MB/channel.
Question: What is the bandwidth for the PXI-5112 Digitizer?
Answer: The PXI-5112 Digitizer has a bandwidth of 100 MHz maximum or 20 MHz typical with bandwidth limit enabled.
Question: How long should I let my PXI-5112 warm up before use?
Answer: The recommended warm-up time for the PXI-5112 is 15 minutes.
PXI-5112 PDF Manuals
ARCHIVED NI 5112 CALIBRATION PROCEDURE.PDF
ARCHIVED NI PCI PXI-5112 SPECIFICATIONS.PDF
ARCHIVED NI PXI 6653 USER MANUAL.PDF
ARCHIVED NI PXI PCI 5112 SPECIFICATIONS.PDF
NI PXI 665X USER MANUAL AND SPECIFICATIONS.PDF
NI PXI 6682 SERIES INSTALLATION GUIDE.PDF
NI PXI 6682 SERIES USER MANUAL AND SPECIFICATIONS.PDF
NI PXI 6682 USER MANUAL AND SPECIFICATIONS.PDF
OSCILLOSCOPES PRODUCT FLYER.PDF
Why Buy From Apex Waves:
PXI-5112
1-800-915-6216
- Description
- Technical Specifications
- FAQ
- PDFs & Diagrams
National Instruments PXI-5112 PXI Digitizer
The NI PXI-5112 PXI Digitizer highlights profound onboard acquisition memory, wide analog bandwidth, and a substantial analog input range in a low-cost model. This model offers two part numbers: 777758-01 with 16 MB/channel and 777756-01 with 32 MB/channel. Since the NI PXI-5112 Digitizer depends on the rapid PCI bus, acquiring and processing expansive waveforms is considerably speedier than with equivalent GPIB-based instruments. Because of this enhanced transfer rate, the user can take estimations speedier and diminish general test time. The NI PXI-5112 has two analog input channels that acknowledge signals going from ±0.025 V to ±25 V, variable in 10 percent steps. Each channel highlights programmable DC offset up to 20 times the input range, depending on the range selected. Accessible AC coupling or DC offset expands the dynamic range of signals that the user can quantify. The user can also force a 20 MHz hardware bandwidth limit for each channel to expel undesirable high-recurrence noise from estimations.
The NI PXI-5112 Digitizer is outfitted with the NI-TIO ASIC, a state-of-the-art counter and timing I/O ASIC created by National Instruments. The NI-TIO digitizer timing motor gives time stamping of records to 2 ns precision for real-time sampling and 100 ps exactness for random-interleaved testing (RIS). Time stamping likewise works in different record procurement mode. With quick rearm times, the user can timestamp activated occasions for up to 130 days with 2 ns precision continuously inspecting mode.
Both analog channels have their own 100 MS/s, 8-bit analog-to-digital converter (ADC), so the user can acquire information at the same time on each channel, at rates from 100 MS/s to 1 S/s. With the NI PXI-5112 high-exactness timing hardware, the user can test repetitive signals at rates up to 2.5 GS/s.
Model | PXI-5112 (777758-01, 777756-01) |
---|---|
Manufacturer | National Instruments |
Type | PXI Oscilloscope |
Onboard Sample Memory | 16 or 32 MB/channel (based on part # purchased) |
Resolution | 8 bits |
Channels | 2 |
Sample Rate | 100 MS/s |
Dimensions | 3.9 x 6.3 in. |
Warranty | One Year Warranty |
PXI-5112 Manual | User Manual and Maintenance Manual Available for Download |
Price | Contact a sales representative for a quote. |
National Instruments PXI-5112 Frequently Asked Questions
Question: Where can I find the manual for the NI PXI-5112?
Answer: The PXI-5112 manual is available for download on the apexwaves.com website.
Question: Why does the PXI-5112 have two part numbers? What are the differences between them?
Answer: The PXI-5112 has two onboard sample memory options, each with a different part number. Part number 777758-01 has 16 MB/channel and part number 777756-01 has 32 MB/channel.
Question: What is the bandwidth for the PXI-5112 Digitizer?
Answer: The PXI-5112 Digitizer has a bandwidth of 100 MHz maximum or 20 MHz typical with bandwidth limit enabled.
Question: How long should I let my PXI-5112 warm up before use?
Answer: The recommended warm-up time for the PXI-5112 is 15 minutes.
PXI-5112 PDF Manuals & Diagrams
PXI-5112 PDF Manuals
ARCHIVED NI 5112 CALIBRATION PROCEDURE.PDF
ARCHIVED NI PCI PXI-5112 SPECIFICATIONS.PDF
ARCHIVED NI PXI 6653 USER MANUAL.PDF
ARCHIVED NI PXI PCI 5112 SPECIFICATIONS.PDF
NI PXI 665X USER MANUAL AND SPECIFICATIONS.PDF
NI PXI 6682 SERIES INSTALLATION GUIDE.PDF
NI PXI 6682 SERIES USER MANUAL AND SPECIFICATIONS.PDF
Why Buy From Apex Waves