National Instruments PXIe-5114 PXI Oscilloscope
The National Instruments PXIe-5114 (Part Numbers: 783591-01, 783591-02, and 783591-03) Oscilloscope has two channels that sample up to 250 MS/s with adaptable arrangement for coupling, impedance, voltage range, and filtering. The NI PXIe-5114 Oscilloscope also has a few different shooting modes, deep inside memory, and an instrument controller that incorporates information recording and examination capacities. This model is perfect for applications with quick signals that require adaptable estimation designs and up to 125 MHz of simple data transfer capacity. The PXIe-5114 additionally has advanced PXI synchronization and data logging abilities.
This model offers an intuitive soft front panel and configuration. The NI-SCOPE Soft Front Panel (SFP) permits intuitive control of the NI PXIe-5114. Smart control of the PXIe-5114 was most readily accessible in NI-SCOPE SFP version 14.1. The NI-SCOPE SFP is incorporated into the NI-SCOPE media. The NI Measurement Automation Explorer (MAX) software additionally gives interactive configuration and test devices for the NI PXIe-5114. MAX is incorporated on the NI-SCOPE media.
This Oscilloscope offers the following features:
• Edge, window, hysteresis, and advanced triggering with 40 ps timestamping
• Pre-trigger and post-trigger acquisition in single-and multiple-record mode
• Internal 250 MHz clock or outer clock from 50 to 250 MHz
• Phase bolt to PXI 10 MHz reference or outer reference from 1 to 20 MHz
• Timestamp-triggered events with 100 ps resolution
• IVI-consistent NI-SCOPE driver for NI LabVIEW and LabWindows/CVI and additionally Microsoft C ++ and Visual Basic with more than 50 built-in estimations
• NI-SCOPE Soft Front Panel for intelligent control
Model | PXIe-5114 |
---|---|
Part Numbers | 783591-01, 783591-02, 783591-03 |
Manufacturer | National Instruments |
Type | PXI Oscilloscope |
Maximum Bandwidth | 125 MHz |
Voltage Input Channels | 2 |
Maximum Sample Rate | 250 MS/s |
Dimensions | 8.4 x 0.8 x 5.1 in. |
Weight | 17.7 oz. |
Warranty | One Year Warranty |
PXIe-5114 Manual | User Manual and Maintenance Manual Available for Download |
Price | Contact a sales representative for a quote. |
National Instruments PXIe-5114 Frequently Asked Questions
Question: What is the difference between the three part numbers for the PXIe-5114?
Answer: There are three part numbers for the PXIe-5114 because there are three onboard memory size choices for this oscilloscope. Part number 783591-01 has 16 MB onboard memory, part number 783591-02 has 128 MB onboard memory, and part number 783591-03 has 512 MB onboard memory.
Question: What is the analog input resolution for the NI PXIe-5114?
Answer: The analog input resolution for the NI PXIe-5114 is 8 bits.
Question: What is the analog input impedance for the PXIe-5114?
Answer: The PXIe-5114 has an analog input impedance of 50 Ohm, 1 MOhm.
Question: Does the NI PXIe-5114 have an FPGA?
Answer: No, the NI PXIe-5114 does not have an FPGA.
PXIe-5114 PDF Manuals
MAINTAIN FORCED AIR COOLING NOTE TO USERS.PDF
NI PXI PXIE PCI 5114 CALIBRATION PROCEDURE.PDF
PCI PXI PXIE 5114 LETTER OF VOLATILITY.PDF
Why Buy From Apex Waves:
PXIe-5114
1-800-915-6216
- Description
- Technical Specifications
- FAQ
- PDFs & Diagrams
National Instruments PXIe-5114 PXI Oscilloscope
The National Instruments PXIe-5114 (Part Numbers: 783591-01, 783591-02, and 783591-03) Oscilloscope has two channels that sample up to 250 MS/s with adaptable arrangement for coupling, impedance, voltage range, and filtering. The NI PXIe-5114 Oscilloscope also has a few different shooting modes, deep inside memory, and an instrument controller that incorporates information recording and examination capacities. This model is perfect for applications with quick signals that require adaptable estimation designs and up to 125 MHz of simple data transfer capacity. The PXIe-5114 additionally has advanced PXI synchronization and data logging abilities.
This model offers an intuitive soft front panel and configuration. The NI-SCOPE Soft Front Panel (SFP) permits intuitive control of the NI PXIe-5114. Smart control of the PXIe-5114 was most readily accessible in NI-SCOPE SFP version 14.1. The NI-SCOPE SFP is incorporated into the NI-SCOPE media. The NI Measurement Automation Explorer (MAX) software additionally gives interactive configuration and test devices for the NI PXIe-5114. MAX is incorporated on the NI-SCOPE media.
This Oscilloscope offers the following features:
• Edge, window, hysteresis, and advanced triggering with 40 ps timestamping
• Pre-trigger and post-trigger acquisition in single-and multiple-record mode
• Internal 250 MHz clock or outer clock from 50 to 250 MHz
• Phase bolt to PXI 10 MHz reference or outer reference from 1 to 20 MHz
• Timestamp-triggered events with 100 ps resolution
• IVI-consistent NI-SCOPE driver for NI LabVIEW and LabWindows/CVI and additionally Microsoft C ++ and Visual Basic with more than 50 built-in estimations
• NI-SCOPE Soft Front Panel for intelligent control
Model | PXIe-5114 |
---|---|
Part Numbers | 783591-01, 783591-02, 783591-03 |
Manufacturer | National Instruments |
Type | PXI Oscilloscope |
Maximum Bandwidth | 125 MHz |
Voltage Input Channels | 2 |
Maximum Sample Rate | 250 MS/s |
Dimensions | 8.4 x 0.8 x 5.1 in. |
Weight | 17.7 oz. |
Warranty | One Year Warranty |
PXIe-5114 Manual | User Manual and Maintenance Manual Available for Download |
Price | Contact a sales representative for a quote. |
National Instruments PXIe-5114 Frequently Asked Questions
Question: What is the difference between the three part numbers for the PXIe-5114?
Answer: There are three part numbers for the PXIe-5114 because there are three onboard memory size choices for this oscilloscope. Part number 783591-01 has 16 MB onboard memory, part number 783591-02 has 128 MB onboard memory, and part number 783591-03 has 512 MB onboard memory.
Question: What is the analog input resolution for the NI PXIe-5114?
Answer: The analog input resolution for the NI PXIe-5114 is 8 bits.
Question: What is the analog input impedance for the PXIe-5114?
Answer: The PXIe-5114 has an analog input impedance of 50 Ohm, 1 MOhm.
Question: Does the NI PXIe-5114 have an FPGA?
Answer: No, the NI PXIe-5114 does not have an FPGA.