PXIe-5171, 8-Channel, 250 MHz, PXI Oscilloscope
Need an Official Quote?
National Instruments PXIe-5171 High-Density Oscilloscope
The National Instruments PXIe-5171 (Part Number: 783692-01) High-density Oscilloscope, with the Kintex-7 FPGA, controls the time in the analog data acquisition channels. The NI PXIe-5171 Oscilloscope also deals with the DRAM access, communicating through the PXIe bus, dealing with the acquisition trigger, and performing any signal processing required. This kind of programmability and adaptability enables National Instruments and its clients to grow, increment, or enhance instrument execution when necessary. The device is equipped with 8 voltage input channels with a maximum bandwidth of 250 MHz, and a maximum sample rate of 250 MS per second.
The PXIe-5171 operates various software options such as the NI-SCOPE driver software, LabVIEW, C/C++/C#, NI-SCOPE soft front panel (SFP), and instrument driver libraries such as LabVIEW FPGA Module and the NI LabVIEW application builder. The device hardware can be configured using the Measurement & Automation Explorer (MAX) tool.
Unlike conventional instrument boxes that can be upgraded at regular intervals, the utilization of FPGA to control all oscilloscope activities enables the instrument to be reconfigured with LabVIEW and LabVIEW FPGA software in minutes, hours, or days, depending on the complexity of the instrument.
The NI PXIe 5171 Oscilloscope has an ADC with signal conditioning that forms the basis of a digitizer. Some measured digitizers, when joined with proper programming, can be sold as oscilloscopes. Notwithstanding, even though the circumstance is step by step changing, Digitizers are frequently measured, while Oscilloscopes are regularly customary bank instruments. This qualification is normally identified with how each sort of gadget is utilized. Oscilloscopes are generally used for problem solving, while digitizers are typically used for data acquisition. The device is equipped with 2 SMA and a MHDMR connector.
The two sorts of instruments usually have a wide range of activation capacities: ways to choose only certain kinds of events from the general signal or synchronize the acquisition with an outside trigger. In addition, particularly in rapid modules, a lot of memory can be incorporated to address a quick information transfer locally. The NI device weighs 17.1 oz., and measures 7.3 x 0.8 x 5.1 in. in dimensions. It has a recommended operating temperature range of 0 °C to 45 °C.
Model | PXIe-5171 |
---|---|
Part Number | 783692-01 |
Manufacturer | National Instruments |
Type | PXI Oscilloscope |
Maximum Bandwidth | 250 MHz |
Voltage Input Channels | 8 |
Maximum Sample Rate | 250 MS/s |
Dimensions | 7.3 x 0.8 x 5.1 in. |
Weight | 17.1 oz. |
Warranty | Three Year Warranty |
PXIe-5171 Manual | User Manual and Maintenance Manual Available for Download |
Price | Contact a sales representative for a quote. |
Associated part numbers for the PXIe-5171:
154487A-01L, 154487C-01L, 154487D-01L, 154490E-01L, 155425A-01L, 155425A-02, 155425B-01L, 155425C-01L, 155425D-01L, 155425E-01L, 200134A-01, 200323A-01, 783692-01, 783693-01
National Instruments PXIe-5171 Frequently Asked Questions
Question: What is the onboard memory size of the PXIe-5171?
Answer: The onboard memory size of the PXIe-5171 is 1.5 GB.
Question: What is the total maximum power allowed for the NI PXIe-5171?
Answer: The total maximum power allowed for the NI PXIe-5171 is 38.25 W.
Question: What is the full bandwidth channel-to-channel skew on the NI PXIe 5171?
Answer: On the NI PXIe 5171, the full bandwidth channel-to-channel skew is <120 ps.
Question: What type of CLK IN source does the PXIe-5171 have?
Answer: The PXIe-5171 has an AUX I/O front panel connector for the CLK IN source.
PXIe-5171 PDF Manuals
NI 5170 5171R LETTER OF VOLATILITY.PDF
NI PXIE 5171R CALIBRATION PROCEDURE.PDF
PXIE 5170 5171 GETTING STARTED GUIDE.PDF
Driver Downloads for PXIe-5171
OS Compatibility:
Win XP 32-bit, Win 7 32-bit, Win 10 32-bit
Why Buy From Apex Waves:
"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"
"They were very helpful to get me the test equipment that I need."
PXIe-5171
Oscilloscopes > National Instruments > Oscilloscopes
PXIe-5171, 8-Channel, 250 MHz, PXI Oscilloscope
1-800-915-6216
- Description
- Technical Specifications
- FAQ
- Manuals & PDFs
- Drivers
National Instruments PXIe-5171 High-Density Oscilloscope
The National Instruments PXIe-5171 (Part Number: 783692-01) High-density Oscilloscope, with the Kintex-7 FPGA, controls the time in the analog data acquisition channels. The NI PXIe-5171 Oscilloscope also deals with the DRAM access, communicating through the PXIe bus, dealing with the acquisition trigger, and performing any signal processing required. This kind of programmability and adaptability enables National Instruments and its clients to grow, increment, or enhance instrument execution when necessary. The device is equipped with 8 voltage input channels with a maximum bandwidth of 250 MHz, and a maximum sample rate of 250 MS per second.
The PXIe-5171 operates various software options such as the NI-SCOPE driver software, LabVIEW, C/C++/C#, NI-SCOPE soft front panel (SFP), and instrument driver libraries such as LabVIEW FPGA Module and the NI LabVIEW application builder. The device hardware can be configured using the Measurement & Automation Explorer (MAX) tool.
Unlike conventional instrument boxes that can be upgraded at regular intervals, the utilization of FPGA to control all oscilloscope activities enables the instrument to be reconfigured with LabVIEW and LabVIEW FPGA software in minutes, hours, or days, depending on the complexity of the instrument.
The NI PXIe 5171 Oscilloscope has an ADC with signal conditioning that forms the basis of a digitizer. Some measured digitizers, when joined with proper programming, can be sold as oscilloscopes. Notwithstanding, even though the circumstance is step by step changing, Digitizers are frequently measured, while Oscilloscopes are regularly customary bank instruments. This qualification is normally identified with how each sort of gadget is utilized. Oscilloscopes are generally used for problem solving, while digitizers are typically used for data acquisition. The device is equipped with 2 SMA and a MHDMR connector.
The two sorts of instruments usually have a wide range of activation capacities: ways to choose only certain kinds of events from the general signal or synchronize the acquisition with an outside trigger. In addition, particularly in rapid modules, a lot of memory can be incorporated to address a quick information transfer locally. The NI device weighs 17.1 oz., and measures 7.3 x 0.8 x 5.1 in. in dimensions. It has a recommended operating temperature range of 0 °C to 45 °C.
Model | PXIe-5171 |
---|---|
Part Number | 783692-01 |
Manufacturer | National Instruments |
Type | PXI Oscilloscope |
Maximum Bandwidth | 250 MHz |
Voltage Input Channels | 8 |
Maximum Sample Rate | 250 MS/s |
Dimensions | 7.3 x 0.8 x 5.1 in. |
Weight | 17.1 oz. |
Warranty | Three Year Warranty |
PXIe-5171 Manual | User Manual and Maintenance Manual Available for Download |
Price | Contact a sales representative for a quote. |
National Instruments PXIe-5171 Frequently Asked Questions
Question: What is the onboard memory size of the PXIe-5171?
Answer: The onboard memory size of the PXIe-5171 is 1.5 GB.
Question: What is the total maximum power allowed for the NI PXIe-5171?
Answer: The total maximum power allowed for the NI PXIe-5171 is 38.25 W.
Question: What is the full bandwidth channel-to-channel skew on the NI PXIe 5171?
Answer: On the NI PXIe 5171, the full bandwidth channel-to-channel skew is <120 ps.
Question: What type of CLK IN source does the PXIe-5171 have?
Answer: The PXIe-5171 has an AUX I/O front panel connector for the CLK IN source.
PXIe-5171 PDF Manuals & Diagrams
PXIe-5171 PDF Manuals
NI 5170 5171R LETTER OF VOLATILITY.PDF
NI PXIE 5171R CALIBRATION PROCEDURE.PDF
PXIE 5170 5171 GETTING STARTED GUIDE.PDF