National Instruments USB-5102 Digitizer
The USB-5102 (Part Numbers: 777650-01, 777650-04, 777650-06, 777650-07, 185182B-01) is a product of National Instruments with two analog input channels. The analog input bandwidth of each channel is 15 MHz. This module also includes software-selectable attenuation, which helps the user achieve a high range of input voltage. The input voltage range is from ±50 mV to ±5 Volts. The attenuation feature can enhance the voltage range up to ±50 Volts. The NI USB-5102 enables the user to build faster automated test systems at a low cost.
The USB-5102 Digitizer can also be used in a high-speed data acquisition system. This device uses a pair of 20 MS/s flash ADCs. Using these ADCs, this device digitizes the input signals. The range of real-time sampling for this device is from 20 MS/s down to 1 kS/s. The USB-5102 allows the user to utilize random-interleaved sampling (RIS). The use of RIS extends the effective sampling to 1 GS/s. This Digitizer has 663,000 samples of on-board acquisition memory and incorporates advanced triggering options.
The National Instruments USB-5102 has two standard BNC female connectors for analog input connections and one standard BNC female connector for the TRIG channel. This Digitizer provides DC accuracy of ±2.5% full scale at all gains. This dual-channel Digitizer additionally offers software-selectable input coupling. The NI USB-5102 provides input protection as well. The value of this input protection is ±42 Volts. The triggering system has an input range of ±5 Volts. The input impedance of this triggering system is 1 MΩ.
Model | USB-5102 |
---|---|
Manufacturer | National Instruments |
Part Numbers | 777650-01, 777650-04, 777650-06, 777650-07, 185182B-01 |
Type | Digitizer |
Channels | 2 |
Bandwidth | 15 MHz |
Resolution | 8 bits |
Dimensions | 5.8 × 8.4 × 1.5 in. |
I/O Connectors | BNC female and SMB female |
Warranty | Three Year Warranty |
USB-5102 Manual | User Manual and Maintenance Manual Available for Download |
Price | Contact a sales representative for a quote. |
Associated part numbers for the USB-5102:
184244C-02, 184244D-03, 185182-01, 185182A-01, 185182B-01, 777650-01, 777650-04, 777650-06, 777650-07
National Instruments USB-5102 Frequently Asked Questions
Question: What is the memory total for the USB-5102?
Answer: The memory total for the USB-5102 is 663 kS to 16 MS.
Question: What is the difference between the various part numbers for the NI USB-5102?
Answer: The NI USB-5102 has a power supply designed for use with different countries/continents. Part number 777650-01 is U.S. 120 VAC. Part number 777650-04 is Universal Euro 240 VAC. The next part number, 777650-06, is United Kingdom 240 VAC. The last part number, 777650-07, is Japanese 100 VAC.
Question: What is the power requirement for the USB-5102?
Answer: The power requirement for the USB-5102 is 4 W maximum for the external power supply.
Why Buy From Apex Waves:
"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"
"They were very helpful to get me the test equipment that I need."
USB-5102
Oscilloscopes > National Instruments > Oscilloscopes
USB-5102, 2-Channel, 15 MHz, Oscilloscope
1-800-915-6216
- Description
- Technical Specifications
- FAQ
- Manuals & PDFs
National Instruments USB-5102 Digitizer
The USB-5102 (Part Numbers: 777650-01, 777650-04, 777650-06, 777650-07, 185182B-01) is a product of National Instruments with two analog input channels. The analog input bandwidth of each channel is 15 MHz. This module also includes software-selectable attenuation, which helps the user achieve a high range of input voltage. The input voltage range is from ±50 mV to ±5 Volts. The attenuation feature can enhance the voltage range up to ±50 Volts. The NI USB-5102 enables the user to build faster automated test systems at a low cost.
The USB-5102 Digitizer can also be used in a high-speed data acquisition system. This device uses a pair of 20 MS/s flash ADCs. Using these ADCs, this device digitizes the input signals. The range of real-time sampling for this device is from 20 MS/s down to 1 kS/s. The USB-5102 allows the user to utilize random-interleaved sampling (RIS). The use of RIS extends the effective sampling to 1 GS/s. This Digitizer has 663,000 samples of on-board acquisition memory and incorporates advanced triggering options.
The National Instruments USB-5102 has two standard BNC female connectors for analog input connections and one standard BNC female connector for the TRIG channel. This Digitizer provides DC accuracy of ±2.5% full scale at all gains. This dual-channel Digitizer additionally offers software-selectable input coupling. The NI USB-5102 provides input protection as well. The value of this input protection is ±42 Volts. The triggering system has an input range of ±5 Volts. The input impedance of this triggering system is 1 MΩ.
Model | USB-5102 |
---|---|
Manufacturer | National Instruments |
Part Numbers | 777650-01, 777650-04, 777650-06, 777650-07, 185182B-01 |
Type | Digitizer |
Channels | 2 |
Bandwidth | 15 MHz |
Resolution | 8 bits |
Dimensions | 5.8 × 8.4 × 1.5 in. |
I/O Connectors | BNC female and SMB female |
Warranty | Three Year Warranty |
USB-5102 Manual | User Manual and Maintenance Manual Available for Download |
Price | Contact a sales representative for a quote. |
National Instruments USB-5102 Frequently Asked Questions
Question: What is the memory total for the USB-5102?
Answer: The memory total for the USB-5102 is 663 kS to 16 MS.
Question: What is the difference between the various part numbers for the NI USB-5102?
Answer: The NI USB-5102 has a power supply designed for use with different countries/continents. Part number 777650-01 is U.S. 120 VAC. Part number 777650-04 is Universal Euro 240 VAC. The next part number, 777650-06, is United Kingdom 240 VAC. The last part number, 777650-07, is Japanese 100 VAC.
Question: What is the power requirement for the USB-5102?
Answer: The power requirement for the USB-5102 is 4 W maximum for the external power supply.
USB-5102 PDF Manuals & Diagrams
USB-5102 PDF Manuals