PCI-4065 National Instruments Digital Multimeter | Apex Waves | ImagePCI-4065 National Instruments Digital Multimeter | Apex Waves | ImagePCI-4065 NewPCI-4065 | Legacy, Refurbished and New Surplus
PCI-4065 National Instruments Digital Multimeter | Apex Waves | Image
PCI-4065 National Instruments Digital Multimeter | Apex Waves | Image
PCI-4065 New
PCI-4065 | Legacy, Refurbished and New Surplus

PCI-4065

4.6/5 | 10 ratings

Modular Systems > National Instruments > PCI Digital Multimeters

Part Number PCI-4065
Manufacturer/Brand National Instruments
Description: PCI-4065, 6.5 Digit, ±300 V, Digital Multimeter Device
In Stock | Ships Today
Fast Quote
Quoted Price
Same Day Calibration Available
2-3 Year Warranty Included
Free Ground Shipping
  Get Pricing

Need an Official Quote?

 

Or speak to a sales representative for additional information:


National Instruments PCI-4065 Digital Multimeter

The National Instruments PCI-4065 (Part numbers: 779770-01, 190310C-01) is a Digital Multimeter Device with 6.5 Digits of Resolution. This device is used for the measurements of analog to digital and digital to analog voltage. This device can also measure analog to digital and digital to analog current, as well as perform diode tests. The NI PCI-4065 is preferable for educational laboratories and OEMs and can also be used for cost-conscious test and measurement applications. The NI PCI-4065 can measure 2 or 4-wire resistance. This DMM is structured with the voltage value of ±300. These values of voltage are measured in either DC or RMS. This DMM offers a comprehensive multimeter solution for basic 6.5 digit measurement requirements. The device has a maximum sample rate of 3 kS/s. It has a basic DC voltage accuracy of 90 ppm.

The PCI-4065 should be calibrated a minimum of one time per year. However, the requirements for each user’s measurement application control how frequently the device should be calibrated. To calibrate the PCI-4065, the user needs a chassis, a multifunction calibrator, two insulated low thermal electromotive force spade lugs, two sets of low thermal electromotive force copper cables, a double banana plug with binding posts, and a way to create a short with low thermal EMF across the HI and LO input banana plug connectors on the PCI-4065. More information about calibrating the device can be found in the calibration procedure guide.

The National Instruments PCI-4065 can measure the current range up to 3 A. The NI PCI-4065 driver is NI-DMM. National Instruments maintains the upgradation of the NI PCI-4065 DMM software, which helps prevent crashes and increases system and hardware performance. The user can obtain information with the Multimeter by using the NI-DMM instrument driver, DMM SFP, NI LabVIEW SignalExpress, or NI-DMM/Switch Express VI. The user can also run the NI-DMM examples to show the functionality of the PCI-4065.

The PCI-4065 weighs 11.5 oz, and measures 7.2 x 0.8 x 4.7 in. in physical dimensions. It has recommended operating and storage temperature ranges of 0 to 40 °C and -40 °C to 70 °C respectively.

The PCI-4065 is available to be calibrated. While the recommended calibration period for individual parts varies, most parts should be calibrated either annually or every two years to ensure accuracy. If you need the PCI-4065 calibrated, Apex Waves provides options. We offer high-quality NIST accredited calibrations through a 3rd party, with an average turnaround time of 1 to 2 weeks. When you order the PCI-4065 with us, you can request basic (unaccredited) in-house calibration that will calibrate the part to the manufacturer specifications prior to being shipped. Call or email us today for more information about calibrating the PCI-4065!

ModelPCI-4065
ManufacturerNational Instruments
Part Numbers779770-01, 190310C-01
TypeDigital Multimeter
Digits of Resolution6.5
Maximum Sample Rate3 kS/s
Basic DC Voltage Accuracy90 ppm
Dimensions7.2 x 0.8 x 4.7 in.
Weight11.5 oz.
WarrantyThree Year Warranty
PCI-4065 ManualUser Manual and Maintenance Manual Available for Download
PriceContact a sales representative for a quote.

Associated part numbers for PCI-4065:

190310A-01, 190310B-01, 190310C-01, 190310D-01L, 190310E-01L, 190310F-01L, 190310G-01L, 190310H-01L, 190310J-01L, 190310K-01L, 190310L-01L, 779770-01

National Instruments PCI-4065 Frequently Asked Questions

 

Question: What is the maximum common-mode voltage of the PCI-4065?

 

Answer: The maximum common-mode voltage of the PCI-4065 is 300 V ACrms or DC.

 

Question: How often should the NI PCI-4065 be calibrated?

 

Answer: The NI PCI-4065 should be calibrated every year.

 

Question: Which types of connectors does the PCI-4065 DMM have?

 

Answer: The PCI-4065 DMM has four shrouded banana plug connectors and a single 9-pin connector.

 

Question: Does the NI PCI-4065 have a user-replaceable fuse?

 

Answer: Yes, the NI PCI-4065 has a user-replaceable fuse. Instructions on how to replace it can be found in the user manual.

  PCI-4065 PDF Manuals

Driver Downloads for PCI-4065






OS Compatibility:
Win XP 32-bit, Win 7 32-bit, Win 10 32-bit

 Download Version


Why Buy From Apex Waves:

Apex Waves Youtube Video

"The business transaction was super easy and friendly."


"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"


"They were very helpful to get me the test equipment that I need."



Delivery:    
UPS, FedEX and DHL – Free Ground on all orders
Overnight, Next Day Air or Expedited shipping options available
International delivery available
Same day shipping for in-stock on location
Warranty: All of our products are covered by our Apex Waves Warranty.
3 Year Warranty - New Surplus Parts
2 Year Warranty - Refurbished Parts
Returns: No hassle return policy.
Dedicated customer service team.
Payment: Authorize.net Visa Master Card American Express BB&T Better Business Bureau Dun & Bradstreet
Quick Quotes: Receive Price & Availability Today!
Calibration: Ask About Our Tiered Calibration Levels
Option & Modules: Confirm Your Requirements or Versions
Repair: Cost & Lead Time Available Upon Request for Service
Repair Evaluation: $150
Share this page: Facebook Icon Twitter Icon LinkedIn Icon
Common Typos: PXI-4065, PFI-4065, PVI-4065, PCI-T065, PCI-4P65

PCI-4065



Modular Systems > National Instruments > PCI Digital Multimeters

PCI-4065
4.6/5 | 10 ratings

PCI-4065, 6.5 Digit, ±300 V, Digital Multimeter Device

In Stock | Ships Today
Same Day Calibration Available
2-3 Year Warranty Included
Free Ground Shipping
  Get Pricing

Call now for best pricing
1-800-915-6216

National Instruments PCI-4065 Digital Multimeter

The National Instruments PCI-4065 (Part numbers: 779770-01, 190310C-01) is a Digital Multimeter Device with 6.5 Digits of Resolution. This device is used for the measurements of analog to digital and digital to analog voltage. This device can also measure analog to digital and digital to analog current, as well as perform diode tests. The NI PCI-4065 is preferable for educational laboratories and OEMs and can also be used for cost-conscious test and measurement applications. The NI PCI-4065 can measure 2 or 4-wire resistance. This DMM is structured with the voltage value of ±300. These values of voltage are measured in either DC or RMS. This DMM offers a comprehensive multimeter solution for basic 6.5 digit measurement requirements. The device has a maximum sample rate of 3 kS/s. It has a basic DC voltage accuracy of 90 ppm.

The PCI-4065 should be calibrated a minimum of one time per year. However, the requirements for each user’s measurement application control how frequently the device should be calibrated. To calibrate the PCI-4065, the user needs a chassis, a multifunction calibrator, two insulated low thermal electromotive force spade lugs, two sets of low thermal electromotive force copper cables, a double banana plug with binding posts, and a way to create a short with low thermal EMF across the HI and LO input banana plug connectors on the PCI-4065. More information about calibrating the device can be found in the calibration procedure guide.

The National Instruments PCI-4065 can measure the current range up to 3 A. The NI PCI-4065 driver is NI-DMM. National Instruments maintains the upgradation of the NI PCI-4065 DMM software, which helps prevent crashes and increases system and hardware performance. The user can obtain information with the Multimeter by using the NI-DMM instrument driver, DMM SFP, NI LabVIEW SignalExpress, or NI-DMM/Switch Express VI. The user can also run the NI-DMM examples to show the functionality of the PCI-4065.

The PCI-4065 weighs 11.5 oz, and measures 7.2 x 0.8 x 4.7 in. in physical dimensions. It has recommended operating and storage temperature ranges of 0 to 40 °C and -40 °C to 70 °C respectively.

The PCI-4065 is available to be calibrated. While the recommended calibration period for individual parts varies, most parts should be calibrated either annually or every two years to ensure accuracy. If you need the PCI-4065 calibrated, Apex Waves provides options. We offer high-quality NIST accredited calibrations through a 3rd party, with an average turnaround time of 1 to 2 weeks. When you order the PCI-4065 with us, you can request basic (unaccredited) in-house calibration that will calibrate the part to the manufacturer specifications prior to being shipped. Call or email us today for more information about calibrating the PCI-4065!

ModelPCI-4065
ManufacturerNational Instruments
Part Numbers779770-01, 190310C-01
TypeDigital Multimeter
Digits of Resolution6.5
Maximum Sample Rate3 kS/s
Basic DC Voltage Accuracy90 ppm
Dimensions7.2 x 0.8 x 4.7 in.
Weight11.5 oz.
WarrantyThree Year Warranty
PCI-4065 ManualUser Manual and Maintenance Manual Available for Download
PriceContact a sales representative for a quote.

National Instruments PCI-4065 Frequently Asked Questions

 

Question: What is the maximum common-mode voltage of the PCI-4065?

 

Answer: The maximum common-mode voltage of the PCI-4065 is 300 V ACrms or DC.

 

Question: How often should the NI PCI-4065 be calibrated?

 

Answer: The NI PCI-4065 should be calibrated every year.

 

Question: Which types of connectors does the PCI-4065 DMM have?

 

Answer: The PCI-4065 DMM has four shrouded banana plug connectors and a single 9-pin connector.

 

Question: Does the NI PCI-4065 have a user-replaceable fuse?

 

Answer: Yes, the NI PCI-4065 has a user-replaceable fuse. Instructions on how to replace it can be found in the user manual.

Software & Drivers





OS Compatibility:
Win XP 32-bit, Win 7 32-bit, Win 10 32-bit

 Download Version

Why Buy From Apex Waves

Apex Waves Youtube Video

"The business transaction was super easy and friendly."


"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"


"They were very helpful to get me the test equipment that I need."


Delivery: UPS, FedEX and DHL – Free FedEx Ground on all orders
Overnight, Next Day Air or Expedited shipping options available
International delivery available
Same day shipping for in-stock on location
Warranty: All of our products are covered by our Apex Waves Warranty.
3 Year Warranty - New Surplus Parts
2 Year Warranty - Refurbished Parts
Returns: No hassle return policy.
Dedicated customer service team.
Payment: Authorize.Net paypal visa card master card american express card BB&T Bank better business bureau
Quick Quotes: Receive Price & Availability Today!
Calibration: Ask About Our Tiered Calibration Levels
Option & Modules: Confirm Your Requirements or Versions
Repair: Cost & Lead Time Available Upon Request for Service
Repair Evaluation: $150
Share this page: facebook twitter linkedIn