PCI-5114 National Instruments Oscilloscope |Apex Waves | ImagePCI-5114 National Instruments Oscilloscope |Apex Waves | ImagePCI-5114 NewPCI-5114 | Legacy, Refurbished and New Surplus
PCI-5114 National Instruments Oscilloscope |Apex Waves | Image
PCI-5114 National Instruments Oscilloscope |Apex Waves | Image
PCI-5114 New
PCI-5114 | Legacy, Refurbished and New Surplus

PCI-5114

4.71/5 | 11 ratings

Oscilloscopes > National Instruments > Oscilloscopes

Part Number PCI-5114
Manufacturer/Brand National Instruments
Description: PCI-5114, 250 MS/s, Oscilloscope
In Stock | Ships in 5-10 Days
(expedited shipping options available)
Fast Quote
Quoted Price
Same Day Calibration Available
2-3 Year Warranty Included
Free Ground Shipping
  Get Pricing

Need an Official Quote?

 

Or speak to a sales representative for additional information:


National Instruments PCI-5114 Oscilloscope

The NI PCI-5114 Oscilloscope includes two 250 MS/s simultaneous sampled input channels with 8-bit resolution, 125 MHz of data transmission, and 256 MB of memory maximum for every channel in a minimized, 3U PCI gadget. With the National Instruments Synchronization and Memory Core (SMC) architecture of a PCI-5114, the user can make mixed signal frameworks by utilizing signal generators and advanced waveform generator/analyzers or assemble a high-channel-count digitizer with sub-nanosecond synchronization between channels. A PCI-5114 is perfect for an extensive variety of applications, including: communications, logical applications, military/aviation, and consumer gadgets.  This model offers three part numbers with varying onboard memory sizes: 779745-01 (8 MB/ch), 779745-02 (64 MB/ch), and 779745-03 (256 MB/ch).

With the elite DMA motor included in this model, the result is high throughput with CPU use. With hyper-threading and multiprocessor abilities, the user can exploit the most recent PC innovation for higher speeds and better productivity. National Instruments likewise offers simple to utilize, capable programming that essentially diminishes the user’s advancement time for frameworks with serial communications.

Self-calibration is accomplished on programming command. The calibration process corrects for gain, counterbalance, repaid 1 Mω attenuator, activating, and timing alteration mistakes for all information ranges. The outer adjustment aligns the VCXO, gain, and the voltage reference. Proper constants are put away in the nonvolatile memory.

The National Instruments PCI-5114 offers 5 GS/s equivalent-time sampling (ETS) for repetitive signals, independent channel-selectable 40 mVpp to 40 Vpp input ranges, independent channel-selectable 50 Ω or 1 MΩ input impedance, and can capture more than 1 million triggered waveforms in multiple record mode with hardware trigger rearming.

Apex Waves will continue to Buy, Sell, and Repair EOL NI Hardware in perpetuity. While the PCI-5114 entered the NI Maintenance phase on December 30, 2022, it will remain available with Apex Waves. Request your quote today!

ModelPCI-5114
ManufacturerNational Instruments
Part Numbers779745-01, 779745-02, 779745-03
TypeOscilloscope
Maximum Bandwidth125 MHz
Maximum Sample Rate250 MS/s
Voltage Input Channels2
Analog Input Resolution8 bits
Dimensions14.0 in × 0.8 in × 4.4 in
Weight14.8 oz
Warranty2-3 Year Warranty
PCI-5114 ManualUser Manual and Maintenance Manual Available for Download
PriceContact a sales representative for a quote.

Associated part numbers for PCI-5114:

191298F-01L, 191814B-01, 191814B-03, 191814B-06, 195681A-01, 195681A-02, 195681A-03, 195681B-01, 195681B-02, 195681B-03, 195681C-01, 195681C-01L, 195681C-02, 195681C-02L, 195681C-03, 195681C-03L, 195681D-01L, 195681D-02L, 195681D-03L, 195681E-01L, 195681E-02L, 195681E-03L, 195681F-01L, 195681F-02L, 195681F-03L, 779745-01, 779745-02, 779745-03

National Instruments PCI-5114 Frequently Asked Questions

Question: Why is the National Instruments PCI-5114 identified by multiple part numbers?


Answer: The National Instruments PCI-5114 can be identified by several part numbers because each part number has a different onboard memory size. The 779745-01 has 8 MB/channel, the 779745-02 has 64 MB/channel, and the 779745-03 has 256 MB/channel.

 

Question: What is the maximum record length for the PCI-5114?

 

Answer: The maximum record length for the PCI-5114 is 1 sample.

 

Question: What type of analog triggers does the NI PCI-5114 come with?

 

Answer: The NI PCI-5114 comes with hysteresis, window, and edge analog trigger types.

 

Question: What is the external clock’s frequency range on the PCI-5114 Oscilloscope?

 

Answer: On the PCI-5114 Oscilloscope, the external clock’s frequency range is 50 MHz to 250 MHz.

  PCI-5114 PDF Manuals

Driver Downloads for PCI-5114






OS Compatibility:
Win XP 32-bit, Win 7 32-bit, Win 10 32-bit

 Download Version


Why Buy From Apex Waves:

Apex Waves Youtube Video

"The business transaction was super easy and friendly."


"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"


"They were very helpful to get me the test equipment that I need."



Delivery:    
UPS, FedEX and DHL – Free Ground on all orders
Overnight, Next Day Air or Expedited shipping options available
International delivery available
Same day shipping for in-stock on location
Warranty: All of our products are covered by our Apex Waves Warranty.
3 Year Warranty - New Surplus Parts
2 Year Warranty - Refurbished Parts
Returns: No hassle return policy.
Dedicated customer service team.
Payment: Authorize.net Visa Master Card American Express BB&T Better Business Bureau Dun & Bradstreet
Quick Quotes: Receive Price & Availability Today!
Calibration: Ask About Our Tiered Calibration Levels
Option & Modules: Confirm Your Requirements or Versions
Repair: Cost & Lead Time Available Upon Request for Service
Repair Evaluation: $150
Share this page: Facebook Icon Twitter Icon LinkedIn Icon
Common Typos: PVI-5114, PCK-5114, PCI-T114, PCI-Y114, PCI-51Q4

PCI-5114



Oscilloscopes > National Instruments > Oscilloscopes

PCI-5114
4.71/5 | 11 ratings

PCI-5114, 250 MS/s, Oscilloscope

In Stock | Ships in 5-10 Days
(expedited shipping options available)
Same Day Calibration Available
2-3 Year Warranty Included
Free Ground Shipping
  Get Pricing

Call now for best pricing
1-800-915-6216

National Instruments PCI-5114 Oscilloscope

The NI PCI-5114 Oscilloscope includes two 250 MS/s simultaneous sampled input channels with 8-bit resolution, 125 MHz of data transmission, and 256 MB of memory maximum for every channel in a minimized, 3U PCI gadget. With the National Instruments Synchronization and Memory Core (SMC) architecture of a PCI-5114, the user can make mixed signal frameworks by utilizing signal generators and advanced waveform generator/analyzers or assemble a high-channel-count digitizer with sub-nanosecond synchronization between channels. A PCI-5114 is perfect for an extensive variety of applications, including: communications, logical applications, military/aviation, and consumer gadgets.  This model offers three part numbers with varying onboard memory sizes: 779745-01 (8 MB/ch), 779745-02 (64 MB/ch), and 779745-03 (256 MB/ch).

With the elite DMA motor included in this model, the result is high throughput with CPU use. With hyper-threading and multiprocessor abilities, the user can exploit the most recent PC innovation for higher speeds and better productivity. National Instruments likewise offers simple to utilize, capable programming that essentially diminishes the user’s advancement time for frameworks with serial communications.

Self-calibration is accomplished on programming command. The calibration process corrects for gain, counterbalance, repaid 1 Mω attenuator, activating, and timing alteration mistakes for all information ranges. The outer adjustment aligns the VCXO, gain, and the voltage reference. Proper constants are put away in the nonvolatile memory.

The National Instruments PCI-5114 offers 5 GS/s equivalent-time sampling (ETS) for repetitive signals, independent channel-selectable 40 mVpp to 40 Vpp input ranges, independent channel-selectable 50 Ω or 1 MΩ input impedance, and can capture more than 1 million triggered waveforms in multiple record mode with hardware trigger rearming.

Apex Waves will continue to Buy, Sell, and Repair EOL NI Hardware in perpetuity. While the PCI-5114 entered the NI Maintenance phase on December 30, 2022, it will remain available with Apex Waves. Request your quote today!

ModelPCI-5114
ManufacturerNational Instruments
Part Numbers779745-01, 779745-02, 779745-03
TypeOscilloscope
Maximum Bandwidth125 MHz
Maximum Sample Rate250 MS/s
Voltage Input Channels2
Analog Input Resolution8 bits
Dimensions14.0 in × 0.8 in × 4.4 in
Weight14.8 oz
Warranty2-3 Year Warranty
PCI-5114 ManualUser Manual and Maintenance Manual Available for Download
PriceContact a sales representative for a quote.

National Instruments PCI-5114 Frequently Asked Questions

Question: Why is the National Instruments PCI-5114 identified by multiple part numbers?


Answer: The National Instruments PCI-5114 can be identified by several part numbers because each part number has a different onboard memory size. The 779745-01 has 8 MB/channel, the 779745-02 has 64 MB/channel, and the 779745-03 has 256 MB/channel.

 

Question: What is the maximum record length for the PCI-5114?

 

Answer: The maximum record length for the PCI-5114 is 1 sample.

 

Question: What type of analog triggers does the NI PCI-5114 come with?

 

Answer: The NI PCI-5114 comes with hysteresis, window, and edge analog trigger types.

 

Question: What is the external clock’s frequency range on the PCI-5114 Oscilloscope?

 

Answer: On the PCI-5114 Oscilloscope, the external clock’s frequency range is 50 MHz to 250 MHz.

Software & Drivers





OS Compatibility:
Win XP 32-bit, Win 7 32-bit, Win 10 32-bit

 Download Version

Why Buy From Apex Waves

Apex Waves Youtube Video

"The business transaction was super easy and friendly."


"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"


"They were very helpful to get me the test equipment that I need."


Delivery: UPS, FedEX and DHL – Free FedEx Ground on all orders
Overnight, Next Day Air or Expedited shipping options available
International delivery available
Same day shipping for in-stock on location
Warranty: All of our products are covered by our Apex Waves Warranty.
3 Year Warranty - New Surplus Parts
2 Year Warranty - Refurbished Parts
Returns: No hassle return policy.
Dedicated customer service team.
Payment: Authorize.Net paypal visa card master card american express card BB&T Bank better business bureau
Quick Quotes: Receive Price & Availability Today!
Calibration: Ask About Our Tiered Calibration Levels
Option & Modules: Confirm Your Requirements or Versions
Repair: Cost & Lead Time Available Upon Request for Service
Repair Evaluation: $150
Share this page: facebook twitter linkedIn