PCI-5142 National Instruments Oscilloscope Device | Apex Waves | ImagePCI-5142 National Instruments Oscilloscope Device | Apex Waves | ImagePCI-5142 NewPCI-5142 | Legacy, Refurbished and New Surplus
PCI-5142 National Instruments Oscilloscope Device | Apex Waves | Image
PCI-5142 National Instruments Oscilloscope Device | Apex Waves | Image
PCI-5142 New
PCI-5142 | Legacy, Refurbished and New Surplus

PCI-5142

4.9/5 | 6 ratings

Oscilloscopes > National Instruments > Oscilloscopes

Part Number PCI-5142
Manufacturer/Brand National Instruments
Description: PCI-5142, 100 MHz Bandwidth, 14-Bit, Oscilloscope Device
Request for Availablility
Fast Quote
Quoted Price
Same Day Calibration Available
2-3 Year Warranty Included
Free Ground Shipping
  Get Pricing

Need an Official Quote?

 

Or speak to a sales representative for additional information:


National Instruments PCI-5142 Oscilloscope Device

The PCI-5142 is an Oscilloscope Device produced by National Instruments. This device is a high-resolution IF digitizer with two channels and 14 bits resolution. It is also capable of low noise measurements. The NI PCI-5142 instrument comes with 100 MHz bandwidth. It has onboard resources for quadrature digital down conversion. The NI PCI-5142 also has baseband I/Q decimation with 40 MHz IF bandwidth. This device is perfect to use for communications measurements and applications involving interfacing with an RF down converter. There are two memory options for the PCI-5142: 64 and 256 MB per channel. Part number 779589-01 comes with 64 MB per channel and part number 779589-02 comes equipped with 256 MB per channel.

The NI PCI-5142 Oscilloscope Device can acquire and examine time and frequency domain analog waveforms. The PCI-5142 has 100 MS/s digitizer. The PCI-5142 is suitable for various applications used in automotive. The military industry and consumer electronics industry also have demand for this device. 

The NI PCI-5142 has a software selectable 50 Ω or 1 MΩ input. The voltage ranges from 200 mV to 20 V. The device is capable of acquiring more than a half million waveforms in the onboard memory. The PCI-5142 is perfect for time and for frequency domain analysis. The NI PCI-5142 is a flexible and software defined instrument. This device is offered in an industrial standard form, which features PCI as well as USB. The device PCI-5142 is equipped with two input channels which can sample at speeds as much as 2 GS/s. The NI PCI-5142 is also equipped with several triggering modes and a deep onboard memory. The device additionally has driver software API.

Apex Waves will continue to Buy, Sell, and Repair EOL NI Hardware in perpetuity. While the PCI-5142 entered the NI Maintenance phase on December 30, 2022, it will remain available with Apex Waves. Request your quote today!

ModelPCI-5142
ManufacturerNational Instruments
Part Numbers779589-01, 779589-02
TypeOscilloscope
Bandwidth100 MHz
Sample Rate100 MS/s
Voltage Input Channels2
Dimensions14.0 x 0.8 x 4.4 in.
Weight16.6 oz.
Warranty2-3 Year Warranty
PCI-5142 ManualUser Manual and Maintenance Manual Available for Download
PriceContact a sales representative for a quote.

Associated part numbers for PCI-5142:

194755B-01L, 194755B-02L, 194755C-01, 194755C-02, 194755D-01, 194755D-02, 194755E-01L, 194755E-02L, 194755F-01L, 194755F-02L, 194755G-01L, 194755G-02L, 194755H-01L, 194755H-02L, 779589-01, 191814B-47, 779589-02, 191814B-48, 779590-01, 191814C-47, 191814C-48, 191814D-47L, 191814D-48L, 191814E-54L, 194755-02, 194755A-01, 194755A-02

National Instruments PCI-5142 Frequently Asked Questions

 

Question: Why does the NI PCI-5142 have two part numbers?

 

Answer: The NI PCI-5142 has two onboard memory size options available. Part number 779589-01 has 64 Mb/channel onboard memory and part number 779589-02 has 256 MB/channel onboard memory.

 

Question: Does the NI PCI-5142 require any accessories?

 

Answer: No, the NI PCI-5142 does not require any accessories, but it can be used with several types of passive probes, active probes, and cables.

 

Question: What are the analog trigger sources on the PCI 5142?

 

Answer: The analog trigger sources on the PCI 5142 are TRIG (front panel BNC connector), CH 0 (front panel BNC connector), and CH 1 (front panel BNC connector).

 

Question: How often should the NI PCI-5142 be calibrated?

 

Answer: The NI PCI-5142 should be calibrated every two years.

  PCI-5142 PDF Manuals

Driver Downloads for PCI-5142






OS Compatibility:
Win XP 32-bit, Win 7 32-bit, Win 10 32-bit

 Download Version


Why Buy From Apex Waves:

Apex Waves Youtube Video

"The business transaction was super easy and friendly."


"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"


"They were very helpful to get me the test equipment that I need."



Delivery:    
UPS, FedEX and DHL – Free Ground on all orders
Overnight, Next Day Air or Expedited shipping options available
International delivery available
Same day shipping for in-stock on location
Warranty: All of our products are covered by our Apex Waves Warranty.
3 Year Warranty - New Surplus Parts
2 Year Warranty - Refurbished Parts
Returns: No hassle return policy.
Dedicated customer service team.
Payment: Authorize.net Visa Master Card American Express BB&T Better Business Bureau Dun & Bradstreet
Quick Quotes: Receive Price & Availability Today!
Calibration: Ask About Our Tiered Calibration Levels
Option & Modules: Confirm Your Requirements or Versions
Repair: Cost & Lead Time Available Upon Request for Service
Repair Evaluation: $150
Share this page: Facebook Icon Twitter Icon LinkedIn Icon
Common Typos: PDI-5142, PCI-Y142, PCI-5W42, PCI-51E2, PCI-51T2

PCI-5142



Oscilloscopes > National Instruments > Oscilloscopes

PCI-5142
4.9/5 | 6 ratings

PCI-5142, 100 MHz Bandwidth, 14-Bit, Oscilloscope Device

Request for Availablility
Same Day Calibration Available
2-3 Year Warranty Included
Free Ground Shipping
  Get Pricing

Call now for best pricing
1-800-915-6216

National Instruments PCI-5142 Oscilloscope Device

The PCI-5142 is an Oscilloscope Device produced by National Instruments. This device is a high-resolution IF digitizer with two channels and 14 bits resolution. It is also capable of low noise measurements. The NI PCI-5142 instrument comes with 100 MHz bandwidth. It has onboard resources for quadrature digital down conversion. The NI PCI-5142 also has baseband I/Q decimation with 40 MHz IF bandwidth. This device is perfect to use for communications measurements and applications involving interfacing with an RF down converter. There are two memory options for the PCI-5142: 64 and 256 MB per channel. Part number 779589-01 comes with 64 MB per channel and part number 779589-02 comes equipped with 256 MB per channel.

The NI PCI-5142 Oscilloscope Device can acquire and examine time and frequency domain analog waveforms. The PCI-5142 has 100 MS/s digitizer. The PCI-5142 is suitable for various applications used in automotive. The military industry and consumer electronics industry also have demand for this device. 

The NI PCI-5142 has a software selectable 50 Ω or 1 MΩ input. The voltage ranges from 200 mV to 20 V. The device is capable of acquiring more than a half million waveforms in the onboard memory. The PCI-5142 is perfect for time and for frequency domain analysis. The NI PCI-5142 is a flexible and software defined instrument. This device is offered in an industrial standard form, which features PCI as well as USB. The device PCI-5142 is equipped with two input channels which can sample at speeds as much as 2 GS/s. The NI PCI-5142 is also equipped with several triggering modes and a deep onboard memory. The device additionally has driver software API.

Apex Waves will continue to Buy, Sell, and Repair EOL NI Hardware in perpetuity. While the PCI-5142 entered the NI Maintenance phase on December 30, 2022, it will remain available with Apex Waves. Request your quote today!

ModelPCI-5142
ManufacturerNational Instruments
Part Numbers779589-01, 779589-02
TypeOscilloscope
Bandwidth100 MHz
Sample Rate100 MS/s
Voltage Input Channels2
Dimensions14.0 x 0.8 x 4.4 in.
Weight16.6 oz.
Warranty2-3 Year Warranty
PCI-5142 ManualUser Manual and Maintenance Manual Available for Download
PriceContact a sales representative for a quote.

National Instruments PCI-5142 Frequently Asked Questions

 

Question: Why does the NI PCI-5142 have two part numbers?

 

Answer: The NI PCI-5142 has two onboard memory size options available. Part number 779589-01 has 64 Mb/channel onboard memory and part number 779589-02 has 256 MB/channel onboard memory.

 

Question: Does the NI PCI-5142 require any accessories?

 

Answer: No, the NI PCI-5142 does not require any accessories, but it can be used with several types of passive probes, active probes, and cables.

 

Question: What are the analog trigger sources on the PCI 5142?

 

Answer: The analog trigger sources on the PCI 5142 are TRIG (front panel BNC connector), CH 0 (front panel BNC connector), and CH 1 (front panel BNC connector).

 

Question: How often should the NI PCI-5142 be calibrated?

 

Answer: The NI PCI-5142 should be calibrated every two years.

Software & Drivers





OS Compatibility:
Win XP 32-bit, Win 7 32-bit, Win 10 32-bit

 Download Version

Why Buy From Apex Waves

Apex Waves Youtube Video

"The business transaction was super easy and friendly."


"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"


"They were very helpful to get me the test equipment that I need."


Delivery: UPS, FedEX and DHL – Free FedEx Ground on all orders
Overnight, Next Day Air or Expedited shipping options available
International delivery available
Same day shipping for in-stock on location
Warranty: All of our products are covered by our Apex Waves Warranty.
3 Year Warranty - New Surplus Parts
2 Year Warranty - Refurbished Parts
Returns: No hassle return policy.
Dedicated customer service team.
Payment: Authorize.Net paypal visa card master card american express card BB&T Bank better business bureau
Quick Quotes: Receive Price & Availability Today!
Calibration: Ask About Our Tiered Calibration Levels
Option & Modules: Confirm Your Requirements or Versions
Repair: Cost & Lead Time Available Upon Request for Service
Repair Evaluation: $150
Share this page: facebook twitter linkedIn