PCI-5154 National Instruments Oscilloscope | Apex Waves | ImagePCI-5154 National Instruments Oscilloscope | Apex Waves | ImagePCI-5154 NewPCI-5154 | Legacy, Refurbished and New Surplus
PCI-5154 National Instruments Oscilloscope | Apex Waves | Image
PCI-5154 National Instruments Oscilloscope | Apex Waves | Image
PCI-5154 New
PCI-5154 | Legacy, Refurbished and New Surplus

PCI-5154

5/5 | 6 ratings

Oscilloscopes > National Instruments > Oscilloscopes

Part Number PCI-5154
Manufacturer/Brand National Instruments
Description: PCI-5154, 2 GS/s, Oscilloscope
In Stock | Ships in 5-10 Days
(expedited shipping options available)
Fast Quote
Quoted Price
Same Day Calibration Available
2-3 Year Warranty Included
Free Ground Shipping
  Get Pricing

Need an Official Quote?

 

Or speak to a sales representative for additional information:


National Instruments PCI-5154 Oscilloscope

Featured with 2 Simultaneously Sampled Channels, the National Instruments PCI-5154 (Part Numbers: 780320-01, 780320-02, and 780320-03) is an 8-bit, 1 GHz Bandwidth, PCI Oscilloscope Device. Each of the two channels on this device can acquire samples independently at a rate around 2 GS/s. These analog input channels are designed to operate at 50 Ω input impedance and support AC, DC, and GND input coupling. The NI PCI-5154 offers a resolution of 8 bits, while the DC accuracy at 0.1 V to 1 V input range remains around ±1.0% of input + 1.3% of FS. This device comes equipped with a 20 MHz noise filter as a bandwidth limit filter and has a typical rise/fall time of 428 ps.

The National Instruments PCI-5154 features an integrated onboard clock (Internal VCSO). This clock has a broad, i.e., 15.26 kS/s to 1 GS/s real-time sampling range. This model can acquire samples within a range of 2 GS/s to 20 GS/s while operating in random interleaved sampling mode. The front panel SMB connector (PFI 0) of this device can provide connection to an external sample clock. The 780320-01 can be plugged into any compatible PCI slot. Thus, the instrument does not require a PXI chassis to become operational.

The National Instruments PCI-5154 is a lightweight and compact device with all connectors mounted on the front panel. This oscilloscope device is offered with 8 MB onboard memory, capable of handling up to 32,768 records. Another brilliant feature of the NI PCI 5154 is its self-calibration capability. The calibration corrects for offset, timing errors, gain, triggering, etc.

Apex Waves will continue to Buy, Sell, and Repair EOL NI Hardware in perpetuity. While the PCI-5154 entered the NI Maintenance phase on December 30, 2022, it will remain available with Apex Waves. Request your quote today!

ModelPCI-5154
ManufacturerNational Instruments
Part Numbers780320-01, 780320-02, 780320-03
TypeOscilloscope
Maximum Bandwidth1 GHz
Maximum Sample Rate2 GS/s
Voltage Input Channels2
Analog Input Resolution8 bits
Dimensions14.0 in × 0.8 in × 4.4 in.
Weight15.5 oz.
Warranty2-3 Year Warranty
PCI-5154 ManualUser Manual and Maintenance Manual Available for Download
PriceContact a sales representative for a quote.

Associated part numbers for PCI-5154:

190380A-01L, 190380A-02L, 190380A-03L, 190380B-01L, 190380B-02L, 190380B-03L, 190380C-01L, 190380C-02L, 190380C-03L, 190380D-01L, 190380D-02L, 190380D-03L, 190380E-01L, 190380E-02L, 190380E-03L, 191616H-02L, 191814D-03L, 191814D-06L, 194013A-02L, 194013A-06L, 780320-01, 780320-02, 780320-03

National Instruments PCI-5154 Frequently Asked Questions

 

Question: How many analog input channels does the NI PCI-5154 have?

 

Answer: The NI PCI-5154 has 2 analog input channels.

 

Question: Why does the PCI-5154 have three different part numbers?

 

Answer: The PCI-5154 has three different options for the onboard memory size: 780320-01 with 8 MB/channel, 780320-02 with 64 MB/channel, and 780320-03 with 256 MB/channel.

 

Question: What is the analog input voltage range on the NI PCI-5154?

 

Answer: The analog input voltage range on the NI PCI-5154 is -2.5 V to 2.5 V.

 

Question: Does the PCI-5154 have an onboard digital downconverter?

 

Answer: No, the PCI-5154 does not have an onboard digital downconverter.

  PCI-5154 PDF Manuals

Driver Downloads for PCI-5154






OS Compatibility:
Win XP 32-bit, Win 7 32-bit, Win 10 32-bit

 Download Version


Why Buy From Apex Waves:

Apex Waves Youtube Video

"The business transaction was super easy and friendly."


"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"


"They were very helpful to get me the test equipment that I need."



Delivery:    
UPS, FedEX and DHL – Free Ground on all orders
Overnight, Next Day Air or Expedited shipping options available
International delivery available
Same day shipping for in-stock on location
Warranty: All of our products are covered by our Apex Waves Warranty.
3 Year Warranty - New Surplus Parts
2 Year Warranty - Refurbished Parts
Returns: No hassle return policy.
Dedicated customer service team.
Payment: Authorize.net Visa Master Card American Express BB&T Better Business Bureau Dun & Bradstreet
Quick Quotes: Receive Price & Availability Today!
Calibration: Ask About Our Tiered Calibration Levels
Option & Modules: Confirm Your Requirements or Versions
Repair: Cost & Lead Time Available Upon Request for Service
Repair Evaluation: $150
Share this page: Facebook Icon Twitter Icon LinkedIn Icon
Common Typos: PXI-5154, PCO-5154, PCI-Y154, PCI-51T4, PCI-515E

PCI-5154



Oscilloscopes > National Instruments > Oscilloscopes

PCI-5154
5/5 | 6 ratings

PCI-5154, 2 GS/s, Oscilloscope

In Stock | Ships in 5-10 Days
(expedited shipping options available)
Same Day Calibration Available
2-3 Year Warranty Included
Free Ground Shipping
  Get Pricing

Call now for best pricing
1-800-915-6216

National Instruments PCI-5154 Oscilloscope

Featured with 2 Simultaneously Sampled Channels, the National Instruments PCI-5154 (Part Numbers: 780320-01, 780320-02, and 780320-03) is an 8-bit, 1 GHz Bandwidth, PCI Oscilloscope Device. Each of the two channels on this device can acquire samples independently at a rate around 2 GS/s. These analog input channels are designed to operate at 50 Ω input impedance and support AC, DC, and GND input coupling. The NI PCI-5154 offers a resolution of 8 bits, while the DC accuracy at 0.1 V to 1 V input range remains around ±1.0% of input + 1.3% of FS. This device comes equipped with a 20 MHz noise filter as a bandwidth limit filter and has a typical rise/fall time of 428 ps.

The National Instruments PCI-5154 features an integrated onboard clock (Internal VCSO). This clock has a broad, i.e., 15.26 kS/s to 1 GS/s real-time sampling range. This model can acquire samples within a range of 2 GS/s to 20 GS/s while operating in random interleaved sampling mode. The front panel SMB connector (PFI 0) of this device can provide connection to an external sample clock. The 780320-01 can be plugged into any compatible PCI slot. Thus, the instrument does not require a PXI chassis to become operational.

The National Instruments PCI-5154 is a lightweight and compact device with all connectors mounted on the front panel. This oscilloscope device is offered with 8 MB onboard memory, capable of handling up to 32,768 records. Another brilliant feature of the NI PCI 5154 is its self-calibration capability. The calibration corrects for offset, timing errors, gain, triggering, etc.

Apex Waves will continue to Buy, Sell, and Repair EOL NI Hardware in perpetuity. While the PCI-5154 entered the NI Maintenance phase on December 30, 2022, it will remain available with Apex Waves. Request your quote today!

ModelPCI-5154
ManufacturerNational Instruments
Part Numbers780320-01, 780320-02, 780320-03
TypeOscilloscope
Maximum Bandwidth1 GHz
Maximum Sample Rate2 GS/s
Voltage Input Channels2
Analog Input Resolution8 bits
Dimensions14.0 in × 0.8 in × 4.4 in.
Weight15.5 oz.
Warranty2-3 Year Warranty
PCI-5154 ManualUser Manual and Maintenance Manual Available for Download
PriceContact a sales representative for a quote.

National Instruments PCI-5154 Frequently Asked Questions

 

Question: How many analog input channels does the NI PCI-5154 have?

 

Answer: The NI PCI-5154 has 2 analog input channels.

 

Question: Why does the PCI-5154 have three different part numbers?

 

Answer: The PCI-5154 has three different options for the onboard memory size: 780320-01 with 8 MB/channel, 780320-02 with 64 MB/channel, and 780320-03 with 256 MB/channel.

 

Question: What is the analog input voltage range on the NI PCI-5154?

 

Answer: The analog input voltage range on the NI PCI-5154 is -2.5 V to 2.5 V.

 

Question: Does the PCI-5154 have an onboard digital downconverter?

 

Answer: No, the PCI-5154 does not have an onboard digital downconverter.

Software & Drivers





OS Compatibility:
Win XP 32-bit, Win 7 32-bit, Win 10 32-bit

 Download Version

Why Buy From Apex Waves

Apex Waves Youtube Video

"The business transaction was super easy and friendly."


"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"


"They were very helpful to get me the test equipment that I need."


Delivery: UPS, FedEX and DHL – Free FedEx Ground on all orders
Overnight, Next Day Air or Expedited shipping options available
International delivery available
Same day shipping for in-stock on location
Warranty: All of our products are covered by our Apex Waves Warranty.
3 Year Warranty - New Surplus Parts
2 Year Warranty - Refurbished Parts
Returns: No hassle return policy.
Dedicated customer service team.
Payment: Authorize.Net paypal visa card master card american express card BB&T Bank better business bureau
Quick Quotes: Receive Price & Availability Today!
Calibration: Ask About Our Tiered Calibration Levels
Option & Modules: Confirm Your Requirements or Versions
Repair: Cost & Lead Time Available Upon Request for Service
Repair Evaluation: $150
Share this page: facebook twitter linkedIn