PCI-6013
Modular Systems > National Instruments > B Series
Description: | NI PCI-6013, 16 Single Ended or 8 Differential Analog Input Channels, 200 kS/s, 16 Bit Multifunction DAQ |
Need an Official Quote?
Or speak to a sales representative for additional information:
National Instruments PCI-6013 Multifunction DAQ
The National Instruments PCI-6013 (Part Number: 778629-01) is a flexible Multifunction DAQ that offers 8 digital I/O lines and two 24-bit counters. Designed to sustain counter/timer and digital operations together in parallel with analog input operations, the NI PCI-6013 is useful for a wide variety of test and measurement applications. Equipped with 16 bits of resolution for analog input, this multifunction DAQ device has a guaranteed maximum sampling rate of 200 KS/s.
There are 16 single-ended analog input channels of the NI PCI-6013, which can easily be configured as 8 differential channels. These channels are software-selectable, allowing for flexible connectivity options. In addition, the device includes 8 digital I/O channels and an SCSI-II type male I/O connector that has 68 pins. The power available at this connector ranges from +4.65 to +5.25 VDC at 1 A. The two up/down counters incorporated in the NI PCI-6013 offer buffered operations, a time base stability of 100 ppm, pulse generation, and TTL logic levels with a maximum range of 5 V.
The NI PCI-6013 boasts a spacious FIFO buffer size of 512 samples alongside a configuration memory size of 512 words. In standard configuration, the power required by the device is 0.7 A at +5 VDC. The PCI-6013 device has a warm-up time of 15 minutes, and it is recommended to calibrate the device once a year to maintain accuracy and reliability. Without connectors, the device measures dimensions of 16.2 cm × 9.2 cm (6.4 in. × 3.6 in.), and it weighs in at 101 g (3.5 oz). For optimal functionality, the PCI-6013 should be operated within temperatures ranging from 0 to 55 °C. When not in use, the device can be safely kept within a storage temperature range of –20 to 70 °C.
While the NI End of Life Status has been announced for the PCI-6013, it will remain available for purchase and repairs with Apex Waves.
Model | PCI-6013 |
---|---|
Manufacturer | National Instruments |
Part Number | 778629-01 |
Series | B Series |
Type | Multifunction DAQ Card |
HTS Code | 8471804000 |
Channels | 16 Analog Inputs (16-Bit, 200 kS/s) or 8 differential 8 Digital Inputs/Outputs (5 V/TTL Compatibility) 2 Counter/Timer I/O (24 bits, 20MHz ) |
I/O Connector | 68-pin male SCSI-II type |
Power Requirements | +5 VDC - 0.7 A |
Dimensions | 6.3 in. × 3.5 in |
Weight | 3.5 oz. |
Driver Software | NI-DAQmx |
Warranty | Three Year Warranty |
PCI-6013 Manual | User Manual and Maintenance Manual Available for Download |
Price | Contact a sales representative for a quote. |
Associated part numbers for PCI-6013:
1886.26, 188626-02, 188626B-02, 188626C-02, 188626D-02, 188626F-02, 188626G-02, 188626H-02, 188626J-02L, 778629-01, 778683-01
National Instruments PCI-6013 Frequently Asked Questions
Question: Which operating systems are compatible with the NI PCI 6013?
Answer: The NI PCI 6013 is compatible with Windows, Linux, Real-Time, and Mac OS operating systems.
Question: What is the maximum voltage range for the PCI 6013 National Instruments?
Answer: The maximum voltage range for the PCI 6013 National Instruments is -10 V, 10 V.
Question: What does the NI PCI-6013 require for operation?
Answer: The NI PCI-6013 requires a connector block, a shielded cable, and software.
Question: Which type of ADC does the PCI 6013 have?
Answer: The PCI 6013 has a successive approximation ADC.
PCI-6013 PDF Manuals
DAQ GETTING STARTED GUIDE FOR PCI PCI EXPRESS.PDF
DAQ GETTING STARTED READ ME FIRST NI DAQMX AND DAQ DEVICE INSTALLATION GUIDE.PDF
NI 6013 6014 FAMILY SPECIFICATIONS.PDF
NI 60XX 60XXE PINOUT LABEL FOR THE SCB 68.PDF
NI 60XX 60XXE PINOUT LABEL FOR THE SCB 68A NOTE TO USER.PDF
Driver Downloads for PCI-6013
OS Compatibility:
Win XP 32-bit, Win 7 32-bit, Win 10 32-bit
Why Buy From Apex Waves:
"The business transaction was super easy and friendly."
"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"
"They were very helpful to get me the test equipment that I need."
PCI-6013
Modular Systems > National Instruments > B Series
1-800-915-6216
- Description
- Technical Specifications
- FAQ
- Manuals & PDFs
- Drivers
National Instruments PCI-6013 Multifunction DAQ
The National Instruments PCI-6013 (Part Number: 778629-01) is a flexible Multifunction DAQ that offers 8 digital I/O lines and two 24-bit counters. Designed to sustain counter/timer and digital operations together in parallel with analog input operations, the NI PCI-6013 is useful for a wide variety of test and measurement applications. Equipped with 16 bits of resolution for analog input, this multifunction DAQ device has a guaranteed maximum sampling rate of 200 KS/s.
There are 16 single-ended analog input channels of the NI PCI-6013, which can easily be configured as 8 differential channels. These channels are software-selectable, allowing for flexible connectivity options. In addition, the device includes 8 digital I/O channels and an SCSI-II type male I/O connector that has 68 pins. The power available at this connector ranges from +4.65 to +5.25 VDC at 1 A. The two up/down counters incorporated in the NI PCI-6013 offer buffered operations, a time base stability of 100 ppm, pulse generation, and TTL logic levels with a maximum range of 5 V.
The NI PCI-6013 boasts a spacious FIFO buffer size of 512 samples alongside a configuration memory size of 512 words. In standard configuration, the power required by the device is 0.7 A at +5 VDC. The PCI-6013 device has a warm-up time of 15 minutes, and it is recommended to calibrate the device once a year to maintain accuracy and reliability. Without connectors, the device measures dimensions of 16.2 cm × 9.2 cm (6.4 in. × 3.6 in.), and it weighs in at 101 g (3.5 oz). For optimal functionality, the PCI-6013 should be operated within temperatures ranging from 0 to 55 °C. When not in use, the device can be safely kept within a storage temperature range of –20 to 70 °C.
While the NI End of Life Status has been announced for the PCI-6013, it will remain available for purchase and repairs with Apex Waves.
Model | PCI-6013 |
---|---|
Manufacturer | National Instruments |
Part Number | 778629-01 |
Series | B Series |
Type | Multifunction DAQ Card |
HTS Code | 8471804000 |
Channels | 16 Analog Inputs (16-Bit, 200 kS/s) or 8 differential 8 Digital Inputs/Outputs (5 V/TTL Compatibility) 2 Counter/Timer I/O (24 bits, 20MHz ) |
I/O Connector | 68-pin male SCSI-II type |
Power Requirements | +5 VDC - 0.7 A |
Dimensions | 6.3 in. × 3.5 in |
Weight | 3.5 oz. |
Driver Software | NI-DAQmx |
Warranty | Three Year Warranty |
PCI-6013 Manual | User Manual and Maintenance Manual Available for Download |
Price | Contact a sales representative for a quote. |
National Instruments PCI-6013 Frequently Asked Questions
Question: Which operating systems are compatible with the NI PCI 6013?
Answer: The NI PCI 6013 is compatible with Windows, Linux, Real-Time, and Mac OS operating systems.
Question: What is the maximum voltage range for the PCI 6013 National Instruments?
Answer: The maximum voltage range for the PCI 6013 National Instruments is -10 V, 10 V.
Question: What does the NI PCI-6013 require for operation?
Answer: The NI PCI-6013 requires a connector block, a shielded cable, and software.
Question: Which type of ADC does the PCI 6013 have?
Answer: The PCI 6013 has a successive approximation ADC.
PCI-6013 PDF Manuals & Diagrams
PCI-6013 PDF Manuals
DAQ GETTING STARTED GUIDE FOR PCI PCI EXPRESS.PDF
DAQ GETTING STARTED READ ME FIRST NI DAQMX AND DAQ DEVICE INSTALLATION GUIDE.PDF
NI 6013 6014 FAMILY SPECIFICATIONS.PDF
NI 60XX 60XXE PINOUT LABEL FOR THE SCB 68.PDF
NI 60XX 60XXE PINOUT LABEL FOR THE SCB 68A NOTE TO USER.PDF
Why Buy From Apex Waves
"The business transaction was super easy and friendly."
"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"
"They were very helpful to get me the test equipment that I need."