Description: NI PCI-6013, 16 Single Ended or 8 Differential Analog Input Channels, 200 kS/s, 16 Bit Multifunction DAQ
In Stock | Ships Today
Fast Quote
Quoted Price
Same Day Calibration Available
2-3 Year Warranty Included
Free Ground Shipping
  Get Pricing

Need an Official Quote?

 

Or speak to a sales representative for additional information:


National Instruments PCI-6013 Multifunction DAQ

The National Instruments PCI-6013 (Part Number: 778629-01) is a flexible Multifunction DAQ that offers 8 digital I/O lines and two 24-bit counters. Designed to sustain counter/timer and digital operations together in parallel with analog input operations, the NI PCI-6013 is useful for a wide variety of test and measurement applications. Equipped with 16 bits of resolution for analog input, this multifunction DAQ device has a guaranteed maximum sampling rate of 200 KS/s. 

There are 16 single-ended analog input channels of the NI PCI-6013, which can easily be configured as 8 differential channels. These channels are software-selectable, allowing for flexible connectivity options. In addition, the device includes 8 digital I/O channels and an SCSI-II type male I/O connector that has 68 pins. The power available at this connector ranges from +4.65 to +5.25 VDC at 1 A. The two up/down counters incorporated in the NI PCI-6013 offer buffered operations, a time base stability of 100 ppm, pulse generation, and TTL logic levels with a maximum range of 5 V. 

 The NI PCI-6013 boasts a spacious FIFO buffer size of 512 samples alongside a configuration memory size of 512 words. In standard configuration, the power required by the device is 0.7 A at +5 VDC. The PCI-6013 device has a warm-up time of 15 minutes, and it is recommended to calibrate the device once a year to maintain accuracy and reliability. Without connectors, the device measures dimensions of 16.2 cm × 9.2 cm (6.4 in. × 3.6 in.), and it weighs in at 101 g (3.5 oz). For optimal functionality, the PCI-6013 should be operated within temperatures ranging from 0 to 55 °C. When not in use, the device can be safely kept within a storage temperature range of –20 to 70 °C.

While the NI End of Life Status has been announced for the PCI-6013, it will remain available for purchase and repairs with Apex Waves.

ModelPCI-6013
ManufacturerNational Instruments
Part Number778629-01
SeriesB Series
TypeMultifunction DAQ Card
HTS Code8471804000
Channels16 Analog Inputs (16-Bit, 200 kS/s) or 8 differential
8 Digital Inputs/Outputs (5 V/TTL Compatibility)
2 Counter/Timer I/O (24 bits, 20MHz )
I/O Connector68-pin male SCSI-II type
Power Requirements+5 VDC - 0.7 A
Dimensions6.3 in. × 3.5 in
Weight3.5 oz.
Driver SoftwareNI-DAQmx
WarrantyThree Year Warranty
PCI-6013 ManualUser Manual and Maintenance Manual Available for Download
PriceContact a sales representative for a quote.

Associated part numbers for PCI-6013:

1886.26, 188626-02, 188626B-02, 188626C-02, 188626D-02, 188626F-02, 188626G-02, 188626H-02, 188626J-02L, 778629-01, 778683-01

National Instruments PCI-6013 Frequently Asked Questions

 

Question: Which operating systems are compatible with the NI PCI 6013?

Answer: The NI PCI 6013 is compatible with Windows, Linux, Real-Time, and Mac OS operating systems.

 

Question: What is the maximum voltage range for the PCI 6013 National Instruments?

Answer: The maximum voltage range for the PCI 6013 National Instruments is -10 V, 10 V.

 

Question: What does the NI PCI-6013 require for operation?

Answer: The NI PCI-6013 requires a connector block, a shielded cable, and software.

 

Question: Which type of ADC does the PCI 6013 have?

Answer: The PCI 6013 has a successive approximation ADC.

  PCI-6013 PDF Manuals

Driver Downloads for PCI-6013






OS Compatibility:
Win XP 32-bit, Win 7 32-bit, Win 10 32-bit

 Download Version


Why Buy From Apex Waves:

Apex Waves Youtube Video

"The business transaction was super easy and friendly."


"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"


"They were very helpful to get me the test equipment that I need."



Delivery:    
UPS, FedEX and DHL – Free Ground on all orders
Overnight, Next Day Air or Expedited shipping options available
International delivery available
Same day shipping for in-stock on location
Warranty: All of our products are covered by our Apex Waves Warranty.
3 Year Warranty - New Surplus Parts
2 Year Warranty - Refurbished Parts
Returns: No hassle return policy.
Dedicated customer service team.
Payment: Authorize.net Visa Master Card American Express BB&T Better Business Bureau Dun & Bradstreet
Quick Quotes: Receive Price & Availability Today!
Calibration: Ask About Our Tiered Calibration Levels
Option & Modules: Confirm Your Requirements or Versions
Repair: Cost & Lead Time Available Upon Request for Service
Repair Evaluation: $150
Share this page: Facebook Icon Twitter Icon LinkedIn Icon
Common Typos: OCI-6013, PXI-6013, PSI-6013, PCU-6013, PCI-6P13

PCI-6013



Modular Systems > National Instruments > B Series

PCI-6013
4.6/5 | 18 ratings

NI PCI-6013, 16 Single Ended or 8 Differential Analog Input Channels, 200 kS/s, 16 Bit Multifunction DAQ

In Stock | Ships Today
Same Day Calibration Available
2-3 Year Warranty Included
Free Ground Shipping
  Get Pricing

Call now for best pricing
1-800-915-6216

National Instruments PCI-6013 Multifunction DAQ

The National Instruments PCI-6013 (Part Number: 778629-01) is a flexible Multifunction DAQ that offers 8 digital I/O lines and two 24-bit counters. Designed to sustain counter/timer and digital operations together in parallel with analog input operations, the NI PCI-6013 is useful for a wide variety of test and measurement applications. Equipped with 16 bits of resolution for analog input, this multifunction DAQ device has a guaranteed maximum sampling rate of 200 KS/s. 

There are 16 single-ended analog input channels of the NI PCI-6013, which can easily be configured as 8 differential channels. These channels are software-selectable, allowing for flexible connectivity options. In addition, the device includes 8 digital I/O channels and an SCSI-II type male I/O connector that has 68 pins. The power available at this connector ranges from +4.65 to +5.25 VDC at 1 A. The two up/down counters incorporated in the NI PCI-6013 offer buffered operations, a time base stability of 100 ppm, pulse generation, and TTL logic levels with a maximum range of 5 V. 

 The NI PCI-6013 boasts a spacious FIFO buffer size of 512 samples alongside a configuration memory size of 512 words. In standard configuration, the power required by the device is 0.7 A at +5 VDC. The PCI-6013 device has a warm-up time of 15 minutes, and it is recommended to calibrate the device once a year to maintain accuracy and reliability. Without connectors, the device measures dimensions of 16.2 cm × 9.2 cm (6.4 in. × 3.6 in.), and it weighs in at 101 g (3.5 oz). For optimal functionality, the PCI-6013 should be operated within temperatures ranging from 0 to 55 °C. When not in use, the device can be safely kept within a storage temperature range of –20 to 70 °C.

While the NI End of Life Status has been announced for the PCI-6013, it will remain available for purchase and repairs with Apex Waves.

ModelPCI-6013
ManufacturerNational Instruments
Part Number778629-01
SeriesB Series
TypeMultifunction DAQ Card
HTS Code8471804000
Channels16 Analog Inputs (16-Bit, 200 kS/s) or 8 differential
8 Digital Inputs/Outputs (5 V/TTL Compatibility)
2 Counter/Timer I/O (24 bits, 20MHz )
I/O Connector68-pin male SCSI-II type
Power Requirements+5 VDC - 0.7 A
Dimensions6.3 in. × 3.5 in
Weight3.5 oz.
Driver SoftwareNI-DAQmx
WarrantyThree Year Warranty
PCI-6013 ManualUser Manual and Maintenance Manual Available for Download
PriceContact a sales representative for a quote.

National Instruments PCI-6013 Frequently Asked Questions

 

Question: Which operating systems are compatible with the NI PCI 6013?

Answer: The NI PCI 6013 is compatible with Windows, Linux, Real-Time, and Mac OS operating systems.

 

Question: What is the maximum voltage range for the PCI 6013 National Instruments?

Answer: The maximum voltage range for the PCI 6013 National Instruments is -10 V, 10 V.

 

Question: What does the NI PCI-6013 require for operation?

Answer: The NI PCI-6013 requires a connector block, a shielded cable, and software.

 

Question: Which type of ADC does the PCI 6013 have?

Answer: The PCI 6013 has a successive approximation ADC.

Software & Drivers





OS Compatibility:
Win XP 32-bit, Win 7 32-bit, Win 10 32-bit

 Download Version

Why Buy From Apex Waves

Apex Waves Youtube Video

"The business transaction was super easy and friendly."


"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"


"They were very helpful to get me the test equipment that I need."


Delivery: UPS, FedEX and DHL – Free FedEx Ground on all orders
Overnight, Next Day Air or Expedited shipping options available
International delivery available
Same day shipping for in-stock on location
Warranty: All of our products are covered by our Apex Waves Warranty.
3 Year Warranty - New Surplus Parts
2 Year Warranty - Refurbished Parts
Returns: No hassle return policy.
Dedicated customer service team.
Payment: Authorize.Net paypal visa card master card american express card BB&T Bank better business bureau
Quick Quotes: Receive Price & Availability Today!
Calibration: Ask About Our Tiered Calibration Levels
Option & Modules: Confirm Your Requirements or Versions
Repair: Cost & Lead Time Available Upon Request for Service
Repair Evaluation: $150
Share this page: facebook twitter linkedIn