PCI-6014 National Instruments Multifunction DAQ | Apex Waves | ImagePCI-6014 National Instruments Multifunction DAQ | Apex Waves | ImagePCI-6014 NewPCI-6014 | Legacy, Refurbished and New Surplus
PCI-6014 National Instruments Multifunction DAQ | Apex Waves | Image
PCI-6014 National Instruments Multifunction DAQ | Apex Waves | Image
PCI-6014 New
PCI-6014 | Legacy, Refurbished and New Surplus

PCI-6014

5/5 | 19 ratings

Modular Systems > National Instruments > B Series

Part Number PCI-6014
Manufacturer/Brand National Instruments
Description: PCI-6014, 16-Bit, 16 Analog Input, Multifunction DAQ
In Stock | Ships Today
Fast Quote
Quoted Price
Same Day Calibration Available
2-3 Year Warranty Included
Free Ground Shipping
  Get Pricing

Need an Official Quote?

 

Or speak to a sales representative for additional information:


National Instruments PCI-6014 Multifunction DAQ

The National Instruments PCI-6014 (Part Number: 778627-01) is a PCI bus based Multifunction Data Acquisition Device (DAQ) suitable for OEMs and less experienced users. This device offers 16 Single-ended or 8 Differential Input Channels and 2 Analog Outputs at resolution of 16 bits. The NI PCI-6014 has ±0.05 to ±10 input range and ±10 output range. This DAQ can acquire samples at 200 kS/s and generate the output at 10 kS/s. This B Series Multifunction DAQ comes equipped with two counters/timers and eight digital I/O.

The ADC (analog-to-digital converter) incorporated in the NI DAQ PCI 6014 is a successive approximation ADC. The Analog Input <0...15> terminals incorporated in the NI PCI 6014 operate under an overvoltage protection set at ±25 V in the operating state and ±15 V in the idle state. The one DMA channel provided on this device has 512 words configuration memory size and can be operated in scatter-gather mode. The National Instruments PCI 6014 comes with 512 samples FIFO buffer size and supports interrupts, DMA, and programmed I/O data transfer modes.

With one 4 bit frequency scaler, two 24 bit up/down counters/timers, and 5 V TTL/CMOS compatibility, the PCI 6014 can be considered for various Timing I/O functions.  Two voltage analog output channels on this device are backed by double-buffered multiplying DACs. These 16-bit resolution channels offer up to 10 kHz maximum update rate. There is a shared DMA channel available to all resources on the board. This device draws 0.7 A of current, weighs around 104 g, and its physical dimensions are 16.2 cm × 9.2 cm. The NI 6014 is equipped with a 68-pin male SCSI-II type I/O connector and has a maximum working voltage of 11V. The device has an ideal operating temperature range of 0 to 55 °C.

The NI 6014 is run using the NI-DAQmx driver software which must be installed first. After installation of the software, the user needs to install support for their choice Application Development Environment-which could be LabVIEW, LabWindows/CVI, C/C++, C#, or Visual Basic .NET.

PCI-6014 Obsolete Status has been announced by National Instruments, but the Multifunction DAQ will still be available for purchase and repairs by Apex Waves.

The PCI-6014 is available to be calibrated. While the recommended calibration period for individual parts varies, most parts should be calibrated either annually or every two years to ensure accuracy. If you need the PCI-6014 calibrated, Apex Waves provides options. We offer high-quality NIST accredited calibrations through a 3rd party, with an average turnaround time of 1 to 2 weeks. When you order the PCI-6014 with us, you can request basic (unaccredited) in-house calibration that will calibrate the part to the manufacturer specifications prior to being shipped. Call or email us today for more information about calibrating the PCI-6014!

ModelPCI-6014
ManufacturerNational Instruments
Part Number778627-01
HTS Code8471804000
SeriesB Series
TypeMultifunction DAQ
Analog Input Channels16
Resolution16-bit
Dimensions6.9 by 4.2 in.
Weight3.6 oz.
Calibration Interval1 year
WarrantyThree Year Warranty
PCI-6014 ManualUser Manual and Maintenance Manual Available for Download
PriceContact a sales representative for a quote.

Associated part numbers for PCI-6014:

18862.6, 188626-01, 188626A-01, 188626B-01, 188626C-01, 188626D-01, 188626F-01, 188626G-01, 188626H-01, 188626J-01L, 778627-01, 778684-01

National Instruments PCI-6014 Frequently Asked Questions

 

Question: Which accessories are required for the PCI 6014?

 

Answer: The PCI 6014 requires the SCC-68 Screw Terminal Connector Block (Part Number: 779475-01) and the 2 m SH68-68-EP Cable (Part Number: 184749-02).

 

Question: Which type of I/O connector does the NI PCI 6014 have?

 

Answer: The NI PCI 6014 has a 68-pin male SCSI-II type.

 

Question: What is the name of the PCI-6014 driver?

 

Answer: The PCI-6014 driver is NI-DAQmx.

 

Question: What is the FIFO buffer size of the PCI 6014 National Instruments?

 

Answer: The PCI 6014 National Instruments does not have a FIFO buffer.

  PCI-6014 PDF Manuals

Driver Downloads for PCI-6014






OS Compatibility:
Win XP 32-bit, Win 7 32-bit, Win 10 32-bit

 Download Version


Why Buy From Apex Waves:

Apex Waves Youtube Video

"The business transaction was super easy and friendly."


"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"


"They were very helpful to get me the test equipment that I need."



Delivery:    
UPS, FedEX and DHL – Free Ground on all orders
Overnight, Next Day Air or Expedited shipping options available
International delivery available
Same day shipping for in-stock on location
Warranty: All of our products are covered by our Apex Waves Warranty.
3 Year Warranty - New Surplus Parts
2 Year Warranty - Refurbished Parts
Returns: No hassle return policy.
Dedicated customer service team.
Payment: Authorize.net Visa Master Card American Express BB&T Better Business Bureau Dun & Bradstreet
Quick Quotes: Receive Price & Availability Today!
Calibration: Ask About Our Tiered Calibration Levels
Option & Modules: Confirm Your Requirements or Versions
Repair: Cost & Lead Time Available Upon Request for Service
Repair Evaluation: $150
Share this page: Facebook Icon Twitter Icon LinkedIn Icon
Common Typos: OCI-6014, PCK-6014, PCI-U014, PCI-60W4, PCI-601R

PCI-6014



Modular Systems > National Instruments > B Series

PCI-6014
5/5 | 19 ratings

PCI-6014, 16-Bit, 16 Analog Input, Multifunction DAQ

In Stock | Ships Today
Same Day Calibration Available
2-3 Year Warranty Included
Free Ground Shipping
  Get Pricing

Call now for best pricing
1-800-915-6216

National Instruments PCI-6014 Multifunction DAQ

The National Instruments PCI-6014 (Part Number: 778627-01) is a PCI bus based Multifunction Data Acquisition Device (DAQ) suitable for OEMs and less experienced users. This device offers 16 Single-ended or 8 Differential Input Channels and 2 Analog Outputs at resolution of 16 bits. The NI PCI-6014 has ±0.05 to ±10 input range and ±10 output range. This DAQ can acquire samples at 200 kS/s and generate the output at 10 kS/s. This B Series Multifunction DAQ comes equipped with two counters/timers and eight digital I/O.

The ADC (analog-to-digital converter) incorporated in the NI DAQ PCI 6014 is a successive approximation ADC. The Analog Input <0...15> terminals incorporated in the NI PCI 6014 operate under an overvoltage protection set at ±25 V in the operating state and ±15 V in the idle state. The one DMA channel provided on this device has 512 words configuration memory size and can be operated in scatter-gather mode. The National Instruments PCI 6014 comes with 512 samples FIFO buffer size and supports interrupts, DMA, and programmed I/O data transfer modes.

With one 4 bit frequency scaler, two 24 bit up/down counters/timers, and 5 V TTL/CMOS compatibility, the PCI 6014 can be considered for various Timing I/O functions.  Two voltage analog output channels on this device are backed by double-buffered multiplying DACs. These 16-bit resolution channels offer up to 10 kHz maximum update rate. There is a shared DMA channel available to all resources on the board. This device draws 0.7 A of current, weighs around 104 g, and its physical dimensions are 16.2 cm × 9.2 cm. The NI 6014 is equipped with a 68-pin male SCSI-II type I/O connector and has a maximum working voltage of 11V. The device has an ideal operating temperature range of 0 to 55 °C.

The NI 6014 is run using the NI-DAQmx driver software which must be installed first. After installation of the software, the user needs to install support for their choice Application Development Environment-which could be LabVIEW, LabWindows/CVI, C/C++, C#, or Visual Basic .NET.

PCI-6014 Obsolete Status has been announced by National Instruments, but the Multifunction DAQ will still be available for purchase and repairs by Apex Waves.

The PCI-6014 is available to be calibrated. While the recommended calibration period for individual parts varies, most parts should be calibrated either annually or every two years to ensure accuracy. If you need the PCI-6014 calibrated, Apex Waves provides options. We offer high-quality NIST accredited calibrations through a 3rd party, with an average turnaround time of 1 to 2 weeks. When you order the PCI-6014 with us, you can request basic (unaccredited) in-house calibration that will calibrate the part to the manufacturer specifications prior to being shipped. Call or email us today for more information about calibrating the PCI-6014!

ModelPCI-6014
ManufacturerNational Instruments
Part Number778627-01
HTS Code8471804000
SeriesB Series
TypeMultifunction DAQ
Analog Input Channels16
Resolution16-bit
Dimensions6.9 by 4.2 in.
Weight3.6 oz.
Calibration Interval1 year
WarrantyThree Year Warranty
PCI-6014 ManualUser Manual and Maintenance Manual Available for Download
PriceContact a sales representative for a quote.

National Instruments PCI-6014 Frequently Asked Questions

 

Question: Which accessories are required for the PCI 6014?

 

Answer: The PCI 6014 requires the SCC-68 Screw Terminal Connector Block (Part Number: 779475-01) and the 2 m SH68-68-EP Cable (Part Number: 184749-02).

 

Question: Which type of I/O connector does the NI PCI 6014 have?

 

Answer: The NI PCI 6014 has a 68-pin male SCSI-II type.

 

Question: What is the name of the PCI-6014 driver?

 

Answer: The PCI-6014 driver is NI-DAQmx.

 

Question: What is the FIFO buffer size of the PCI 6014 National Instruments?

 

Answer: The PCI 6014 National Instruments does not have a FIFO buffer.

Software & Drivers





OS Compatibility:
Win XP 32-bit, Win 7 32-bit, Win 10 32-bit

 Download Version

Why Buy From Apex Waves

Apex Waves Youtube Video

"The business transaction was super easy and friendly."


"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"


"They were very helpful to get me the test equipment that I need."


Delivery: UPS, FedEX and DHL – Free FedEx Ground on all orders
Overnight, Next Day Air or Expedited shipping options available
International delivery available
Same day shipping for in-stock on location
Warranty: All of our products are covered by our Apex Waves Warranty.
3 Year Warranty - New Surplus Parts
2 Year Warranty - Refurbished Parts
Returns: No hassle return policy.
Dedicated customer service team.
Payment: Authorize.Net paypal visa card master card american express card BB&T Bank better business bureau
Quick Quotes: Receive Price & Availability Today!
Calibration: Ask About Our Tiered Calibration Levels
Option & Modules: Confirm Your Requirements or Versions
Repair: Cost & Lead Time Available Upon Request for Service
Repair Evaluation: $150
Share this page: facebook twitter linkedIn