Part Number PCI-6280
Manufacturer/Brand National Instruments
Description: PCI-6280, 16 AI, 24 DIO, 18-Bit, Multifunction DAQ
In Stock | Ships Today
Fast Quote
Quoted Price
Same Day Calibration Available
2-3 Year Warranty Included
Free Ground Shipping
  Get Pricing

Need an Official Quote?

 

Or speak to a sales representative for additional information:


National Instruments PCI-6280 Multifunction DAQ

The PCI-6280 is a Multifunction DAQ designed by National Instruments. This model is available under part number 779108-01. This device is a low cost yet reliable DAQ card for PCI slots. The PCI-6280 device supports SCC and SCXI signal conditioning modules. The PCI-6280 device has a built-in configuration utility and NI-DAQmx driver. These features make it simple to configure the card for measurements. The module features analog and digital terminals, along with built-in timers in a single device. This device is used in many research and industry applications.

The PCI-6280 Multifunction DAQ incorporates eight differential channels as inputs. The ADC resolution of these channels is 18 bits. It can read samples at a maximum rate of 625 kS/sec. The input voltage of the analog channels is from +10 V to +0.1V. The default range of the working voltage is +10V. The PCI-6280 device has protection against overvoltage and can bear up to +25 V without getting damaged. When an overvoltage is given to input terminals, the input current is +20 mA. An analog trigger is also provided in the PCI-6280 with an accuracy of +1 %. The input impedance of the analog trigger is 10 kΩ. The analog channels of the PCI-6280 device are DC-coupled.  24 digital channels are also provided in the PCI-6280. Each channel can be programmed independently as inputs or outputs.

The PCI-6280 device has two 32-bit general-purpose counters/timers. The counters have both internal and external base clocks. The FIFO buffer memory of counters is two samples. This device is also equipped with a frequency generator with a base clock accuracy of 50 ppm.

ModelPCI-6280
ManufacturerNational Instruments
Part Number779108-01
SeriesM Series
TypeMultifunction DAQ Device
Analog Input Channels16 (18-Bit, 625 kS/s) or 08 differential
Digital Input/Output24
Timing I/O2 Counter/Timer I/O (32 bits, 80 MHz)
Frequency Generator Channels1
I/O Connector1 68-pin VHDCI
Power Requirements+5 V, +3.3 V, +12 V, -12 V -- 0.03 A, 0.78 A, 0.40 A, 0.06 A
Dimensions4.2 in. × 6.1 in.
Weight0.33 lb.
Driver SoftwareNI-DAQmx
Warranty2-3 Year Warranty
PCI-6280 ManualUser Manual and Maintenance Manual Available for Download
PriceContact a sales representative for a quote.

Associated part numbers for PCI-6280:

191342A-04, 191342B-04L, 191342D-04L, 191342E-04L, 191342F-04L, 191342G-04L, 779108-01

National Instruments PCI-6280 Frequently Asked Questions

 

Question: Error 88705 appeared on the NI PCI 6280. I removed the board, but it still shows up in MAX. I cannot install it in a different slot because it cannot be deleted; the option is grayed out. How do I resolve the problem?

 

Answer: The issue may be a result of corruption of the MAX database. If you clear the MAX database, then you should be able to re-install the NI PCI 6280 in a different slot.

 

Question: Are the connectors of the PCI 6280 male or female?

 

Answer: PCI DAQ Boards such as the PCI 6280 have male connectors.

 

Question: Which types of measurement software are required for the NI PCI-6280?

 

Answer: The NI PCI-6280 requires LabVIEW SignalExpress LE data-logging software, NI- DAQmx driver software, and Measurement & Automation Explorer configuration utility.

 

Question: Does the PCI-6280 require any accessories?

 

Answer: Yes, the PCI-6280 requires a Connector Block such as the SCB-68A Noise Rejecting, Shielded I/O Connector Block (Part Number: 782536-01) and a Multifunction Cable like the 2 m SHC68-68-EPM Shielded Cable, 68-D-Type to 68 VHDCI Offset (Part Number: 192061-02).

  PCI-6280 PDF Manuals


Why Buy From Apex Waves:

Apex Waves Youtube Video

"The business transaction was super easy and friendly."


"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"


"They were very helpful to get me the test equipment that I need."



Delivery:    
UPS, FedEX and DHL – Free Ground on all orders
Overnight, Next Day Air or Expedited shipping options available
International delivery available
Same day shipping for in-stock on location
Warranty: All of our products are covered by our Apex Waves Warranty.
3 Year Warranty - New Surplus Parts
2 Year Warranty - Refurbished Parts
Returns: No hassle return policy.
Dedicated customer service team.
Payment: Authorize.net Visa Master Card American Express BB&T Better Business Bureau Dun & Bradstreet
Quick Quotes: Receive Price & Availability Today!
Calibration: Ask About Our Tiered Calibration Levels
Option & Modules: Confirm Your Requirements or Versions
Repair: Cost & Lead Time Available Upon Request for Service
Repair Evaluation: $150
Share this page: Facebook Icon Twitter Icon LinkedIn Icon
Common Typos: PXI-6280, PVI-6280, PCU-6280, PCI-T280, PCI-6Q80

PCI-6280



Modular Systems > National Instruments > M Series

PCI-6280
4.6/5 | 11 ratings

PCI-6280, 16 AI, 24 DIO, 18-Bit, Multifunction DAQ

In Stock | Ships Today
Same Day Calibration Available
2-3 Year Warranty Included
Free Ground Shipping
  Get Pricing

Call now for best pricing
1-800-915-6216

National Instruments PCI-6280 Multifunction DAQ

The PCI-6280 is a Multifunction DAQ designed by National Instruments. This model is available under part number 779108-01. This device is a low cost yet reliable DAQ card for PCI slots. The PCI-6280 device supports SCC and SCXI signal conditioning modules. The PCI-6280 device has a built-in configuration utility and NI-DAQmx driver. These features make it simple to configure the card for measurements. The module features analog and digital terminals, along with built-in timers in a single device. This device is used in many research and industry applications.

The PCI-6280 Multifunction DAQ incorporates eight differential channels as inputs. The ADC resolution of these channels is 18 bits. It can read samples at a maximum rate of 625 kS/sec. The input voltage of the analog channels is from +10 V to +0.1V. The default range of the working voltage is +10V. The PCI-6280 device has protection against overvoltage and can bear up to +25 V without getting damaged. When an overvoltage is given to input terminals, the input current is +20 mA. An analog trigger is also provided in the PCI-6280 with an accuracy of +1 %. The input impedance of the analog trigger is 10 kΩ. The analog channels of the PCI-6280 device are DC-coupled.  24 digital channels are also provided in the PCI-6280. Each channel can be programmed independently as inputs or outputs.

The PCI-6280 device has two 32-bit general-purpose counters/timers. The counters have both internal and external base clocks. The FIFO buffer memory of counters is two samples. This device is also equipped with a frequency generator with a base clock accuracy of 50 ppm.

ModelPCI-6280
ManufacturerNational Instruments
Part Number779108-01
SeriesM Series
TypeMultifunction DAQ Device
Analog Input Channels16 (18-Bit, 625 kS/s) or 08 differential
Digital Input/Output24
Timing I/O2 Counter/Timer I/O (32 bits, 80 MHz)
Frequency Generator Channels1
I/O Connector1 68-pin VHDCI
Power Requirements+5 V, +3.3 V, +12 V, -12 V -- 0.03 A, 0.78 A, 0.40 A, 0.06 A
Dimensions4.2 in. × 6.1 in.
Weight0.33 lb.
Driver SoftwareNI-DAQmx
Warranty2-3 Year Warranty
PCI-6280 ManualUser Manual and Maintenance Manual Available for Download
PriceContact a sales representative for a quote.

National Instruments PCI-6280 Frequently Asked Questions

 

Question: Error 88705 appeared on the NI PCI 6280. I removed the board, but it still shows up in MAX. I cannot install it in a different slot because it cannot be deleted; the option is grayed out. How do I resolve the problem?

 

Answer: The issue may be a result of corruption of the MAX database. If you clear the MAX database, then you should be able to re-install the NI PCI 6280 in a different slot.

 

Question: Are the connectors of the PCI 6280 male or female?

 

Answer: PCI DAQ Boards such as the PCI 6280 have male connectors.

 

Question: Which types of measurement software are required for the NI PCI-6280?

 

Answer: The NI PCI-6280 requires LabVIEW SignalExpress LE data-logging software, NI- DAQmx driver software, and Measurement & Automation Explorer configuration utility.

 

Question: Does the PCI-6280 require any accessories?

 

Answer: Yes, the PCI-6280 requires a Connector Block such as the SCB-68A Noise Rejecting, Shielded I/O Connector Block (Part Number: 782536-01) and a Multifunction Cable like the 2 m SHC68-68-EPM Shielded Cable, 68-D-Type to 68 VHDCI Offset (Part Number: 192061-02).

Why Buy From Apex Waves

Apex Waves Youtube Video

"The business transaction was super easy and friendly."


"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"


"They were very helpful to get me the test equipment that I need."


Delivery: UPS, FedEX and DHL – Free FedEx Ground on all orders
Overnight, Next Day Air or Expedited shipping options available
International delivery available
Same day shipping for in-stock on location
Warranty: All of our products are covered by our Apex Waves Warranty.
3 Year Warranty - New Surplus Parts
2 Year Warranty - Refurbished Parts
Returns: No hassle return policy.
Dedicated customer service team.
Payment: Authorize.Net paypal visa card master card american express card BB&T Bank better business bureau
Quick Quotes: Receive Price & Availability Today!
Calibration: Ask About Our Tiered Calibration Levels
Option & Modules: Confirm Your Requirements or Versions
Repair: Cost & Lead Time Available Upon Request for Service
Repair Evaluation: $150
Share this page: facebook twitter linkedIn