PCI-6601 National Instruments Counter/Timer Device | Apex Waves | ImagePCI-6601 National Instruments Counter/Timer Device | Apex Waves | ImagePCI-6601 NewPCI-6601 | Legacy, Refurbished and New Surplus
PCI-6601 National Instruments Counter/Timer Device | Apex Waves | Image
PCI-6601 National Instruments Counter/Timer Device | Apex Waves | Image
PCI-6601 New
PCI-6601 | Legacy, Refurbished and New Surplus

PCI-6601

4.9/5 | 5 ratings

Modular Systems > National Instruments > PCI Multifunction Devices

Part Number PCI-6601
Manufacturer/Brand National Instruments
Description: PCI-6601, 32 Digital Channels, 4 Counters/Times, 5 V TTL, Counter/Timer Device
In Stock | Ships Today
Fast Quote
Quoted Price
Same Day Calibration Available
2-3 Year Warranty Included
Free Ground Shipping
  Get Pricing

Need an Official Quote?

 

Or speak to a sales representative for additional information:


National Instruments PCI-6601 Counter/Timer Device

The PCI‑6601 (Part Number: 777918-01) performs encoder position estimations, event checking, period estimations, pulse width estimations, pulse generation, pulse prepare generation, and frequency estimation. The PCI‑6601 can perform one rapid DMA exchange. The NI PCI-6601 is a timing and computerized I/O gadget for use with the PCI bus in PC compatible PCs, PXI frame, or CompactPCI body. The National Instruments NI PCI 6601 offers 32 bidirectional digital channels and up to 32 lines of exclusively configurable, TTL/CMOS-compatible advanced I/O.

This model comes with a pre-scaling function that enables the counter to check a signal that is speedier than the most extreme time-base of the counter. The counters on the PCI 6601 National Instruments device offer 8X and 2X pre-scaling on each counter (pre-scaling can be handicapped).
Each pre-scaler is comprised of a little, basic counter that tallies to eight (or two) and moves over. This counter is particularly intended for this application and can tally flags that are speedier than the universally useful counters. The CtrnSource motion on the broadly useful counter will be the separated flag from the straightforward counter. Pre-scaling is expected for use with two counter period and frequency estimations where the estimation is made on a ceaseless, tedious signal. The pre-scaling counter cannot be perused, so the user cannot decide what number of edges have happened since the past move over. The user can utilize pre-scaling for tallying edges if it is adequate to have a mistake of up to seven when utilizing 8X pre-scaling or one when utilizing 2X pre-scaling. The PCI 6601 is equipped with a 68-pin male SCSI-II type I/O connector.

The Counter/Timer device can be calibrated using the traditional NI-DAQ 7.4.4 which is compatible with software packages or application development environments (ADEs) such as LabVIEW, LabWindows/CVI, Microsoft Visual C++, Microsoft Visual Basic, and Borland C++.

The NI device measures 6.9 x 3.9 in. in physical dimensions. It has recommended operating and storage temperature ranges of 0 °C to 55 °C and 20 °C to 70 °C.

PCI-6601 Mature Status has been announced by National Instruments, but will be available for purchase and repairs by Apex Waves. 

The PCI-6601 is available to be calibrated. While the recommended calibration period for individual parts varies, most parts should be calibrated either annually or every two years to ensure accuracy. If you need the PCI-6601 calibrated, Apex Waves provides options. We offer high-quality NIST accredited calibrations through a 3rd party, with an average turnaround time of 1 to 2 weeks. When you order the PCI-6601 with us, you can request basic (unaccredited) in-house calibration that will calibrate the part to the manufacturer specifications prior to being shipped. Call or email us today for more information about calibrating the PCI-6601!

ModelPCI-6601
ManufacturerNational Instruments
Part Number777918-01
TypeCounter/Timer Device
Digital I/O32 (5 V TTL/CMOS Compatibility)
Max Source Frequency20 MHz
Counter/Timers4 (32 bits - 12.5 ns resolution)
I/O Connector68-pin male SCSI-II type
Power Requirements+5VDC -- 0.4 A to 0.75 A
Dimensions6.9 by 3.9 in.
Software DriverNI-DAQ 7
WarrantyThree Year Warranty
PCI-6601 ManualUser Manual and Maintenance Manual Available for Download
PriceContact a sales representative for a quote.

Associated part numbers for PCI-6601:

1844.79, 184479-02, 184479A-02, 184479B-02, 184479C-02, 184479D-02, 184479F-02, 184479G-02L, 184479H-02L, 777918-01

National Instruments PCI-6601 Frequently Asked Questions

 

Question: I am using the National Instruments NI PCI-6601 to measure the pulse width with eight counter input channels. Using multiple channels causes Error -200251. How do I resolve the issue?

 

Answer: The National Instruments NI PCI-6601 has a specified number of DMA routes for use. If you try to use more channels than the card has DMA routes for, then this error will appear. The PCI-6601 only has 1 DMA channel. The easiest way to change this is to change the transfer method. First, locate the DAQmx Channel Property Node on the DAQmx palette. Right click in the block diagram and go to Measurement I/O » DAQmx » DAQmx Channel Property Node. Place this node on the block diagram and connect the task input to the counter task you would like to configure. To locate the Data Transfer Mechanism Property, click on Property and select Counter Input » General Properties » More » Advanced » Data Transfer and Memory » Data Transfer Mechanism. Set this property to write and create a constant for the input. You can now select any of the various methods for the transfer method (DMA, Interrupts, Programmed I/O, USB bulk).

 

Question: Which items are required to use the PCI 6601?

 

Answer: To use the PCI 6601, you need NI-DAQ for PC compatibles, LabWindows/CVI, or LabVIEW for Windows, as well as a computer or a CompactPCI or PXI chassis and controller, a shielded (SH68-68-D1) or ribbon (R6868) cable, and a SCB-68, TBX-68, or CB-68LP connector block.

 

Question: Which special features are included on the PCI 6601 National Instruments?

 

Answer: The PCI 6601 National Instruments has pulse generation, debouncing/glitch removal, and buffered operations.

 

Question: Which driver software supports the NI PCI 6601?

 

Answer: The NI PCI 6601 driver software supported is NI-DAQ 7.

  PCI-6601 PDF Manuals


Why Buy From Apex Waves:

Apex Waves Youtube Video

"The business transaction was super easy and friendly."


"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"


"They were very helpful to get me the test equipment that I need."



Delivery:    
UPS, FedEX and DHL – Free Ground on all orders
Overnight, Next Day Air or Expedited shipping options available
International delivery available
Same day shipping for in-stock on location
Warranty: All of our products are covered by our Apex Waves Warranty.
3 Year Warranty - New Surplus Parts
2 Year Warranty - Refurbished Parts
Returns: No hassle return policy.
Dedicated customer service team.
Payment: Authorize.net Visa Master Card American Express BB&T Better Business Bureau Dun & Bradstreet
Quick Quotes: Receive Price & Availability Today!
Calibration: Ask About Our Tiered Calibration Levels
Option & Modules: Confirm Your Requirements or Versions
Repair: Cost & Lead Time Available Upon Request for Service
Repair Evaluation: $150
Share this page: Facebook Icon Twitter Icon LinkedIn Icon
Common Typos: OCI-6601, PDI-6601, PFI-6601, PCI-U601, PCI-66P1

PCI-6601



Modular Systems > National Instruments > PCI Multifunction Devices

PCI-6601
4.9/5 | 5 ratings

PCI-6601, 32 Digital Channels, 4 Counters/Times, 5 V TTL, Counter/Timer Device

In Stock | Ships Today
Same Day Calibration Available
2-3 Year Warranty Included
Free Ground Shipping
  Get Pricing

Call now for best pricing
1-800-915-6216

National Instruments PCI-6601 Counter/Timer Device

The PCI‑6601 (Part Number: 777918-01) performs encoder position estimations, event checking, period estimations, pulse width estimations, pulse generation, pulse prepare generation, and frequency estimation. The PCI‑6601 can perform one rapid DMA exchange. The NI PCI-6601 is a timing and computerized I/O gadget for use with the PCI bus in PC compatible PCs, PXI frame, or CompactPCI body. The National Instruments NI PCI 6601 offers 32 bidirectional digital channels and up to 32 lines of exclusively configurable, TTL/CMOS-compatible advanced I/O.

This model comes with a pre-scaling function that enables the counter to check a signal that is speedier than the most extreme time-base of the counter. The counters on the PCI 6601 National Instruments device offer 8X and 2X pre-scaling on each counter (pre-scaling can be handicapped).
Each pre-scaler is comprised of a little, basic counter that tallies to eight (or two) and moves over. This counter is particularly intended for this application and can tally flags that are speedier than the universally useful counters. The CtrnSource motion on the broadly useful counter will be the separated flag from the straightforward counter. Pre-scaling is expected for use with two counter period and frequency estimations where the estimation is made on a ceaseless, tedious signal. The pre-scaling counter cannot be perused, so the user cannot decide what number of edges have happened since the past move over. The user can utilize pre-scaling for tallying edges if it is adequate to have a mistake of up to seven when utilizing 8X pre-scaling or one when utilizing 2X pre-scaling. The PCI 6601 is equipped with a 68-pin male SCSI-II type I/O connector.

The Counter/Timer device can be calibrated using the traditional NI-DAQ 7.4.4 which is compatible with software packages or application development environments (ADEs) such as LabVIEW, LabWindows/CVI, Microsoft Visual C++, Microsoft Visual Basic, and Borland C++.

The NI device measures 6.9 x 3.9 in. in physical dimensions. It has recommended operating and storage temperature ranges of 0 °C to 55 °C and 20 °C to 70 °C.

PCI-6601 Mature Status has been announced by National Instruments, but will be available for purchase and repairs by Apex Waves. 

The PCI-6601 is available to be calibrated. While the recommended calibration period for individual parts varies, most parts should be calibrated either annually or every two years to ensure accuracy. If you need the PCI-6601 calibrated, Apex Waves provides options. We offer high-quality NIST accredited calibrations through a 3rd party, with an average turnaround time of 1 to 2 weeks. When you order the PCI-6601 with us, you can request basic (unaccredited) in-house calibration that will calibrate the part to the manufacturer specifications prior to being shipped. Call or email us today for more information about calibrating the PCI-6601!

ModelPCI-6601
ManufacturerNational Instruments
Part Number777918-01
TypeCounter/Timer Device
Digital I/O32 (5 V TTL/CMOS Compatibility)
Max Source Frequency20 MHz
Counter/Timers4 (32 bits - 12.5 ns resolution)
I/O Connector68-pin male SCSI-II type
Power Requirements+5VDC -- 0.4 A to 0.75 A
Dimensions6.9 by 3.9 in.
Software DriverNI-DAQ 7
WarrantyThree Year Warranty
PCI-6601 ManualUser Manual and Maintenance Manual Available for Download
PriceContact a sales representative for a quote.

National Instruments PCI-6601 Frequently Asked Questions

 

Question: I am using the National Instruments NI PCI-6601 to measure the pulse width with eight counter input channels. Using multiple channels causes Error -200251. How do I resolve the issue?

 

Answer: The National Instruments NI PCI-6601 has a specified number of DMA routes for use. If you try to use more channels than the card has DMA routes for, then this error will appear. The PCI-6601 only has 1 DMA channel. The easiest way to change this is to change the transfer method. First, locate the DAQmx Channel Property Node on the DAQmx palette. Right click in the block diagram and go to Measurement I/O » DAQmx » DAQmx Channel Property Node. Place this node on the block diagram and connect the task input to the counter task you would like to configure. To locate the Data Transfer Mechanism Property, click on Property and select Counter Input » General Properties » More » Advanced » Data Transfer and Memory » Data Transfer Mechanism. Set this property to write and create a constant for the input. You can now select any of the various methods for the transfer method (DMA, Interrupts, Programmed I/O, USB bulk).

 

Question: Which items are required to use the PCI 6601?

 

Answer: To use the PCI 6601, you need NI-DAQ for PC compatibles, LabWindows/CVI, or LabVIEW for Windows, as well as a computer or a CompactPCI or PXI chassis and controller, a shielded (SH68-68-D1) or ribbon (R6868) cable, and a SCB-68, TBX-68, or CB-68LP connector block.

 

Question: Which special features are included on the PCI 6601 National Instruments?

 

Answer: The PCI 6601 National Instruments has pulse generation, debouncing/glitch removal, and buffered operations.

 

Question: Which driver software supports the NI PCI 6601?

 

Answer: The NI PCI 6601 driver software supported is NI-DAQ 7.

Why Buy From Apex Waves

Apex Waves Youtube Video

"The business transaction was super easy and friendly."


"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"


"They were very helpful to get me the test equipment that I need."


Delivery: UPS, FedEX and DHL – Free FedEx Ground on all orders
Overnight, Next Day Air or Expedited shipping options available
International delivery available
Same day shipping for in-stock on location
Warranty: All of our products are covered by our Apex Waves Warranty.
3 Year Warranty - New Surplus Parts
2 Year Warranty - Refurbished Parts
Returns: No hassle return policy.
Dedicated customer service team.
Payment: Authorize.Net paypal visa card master card american express card BB&T Bank better business bureau
Quick Quotes: Receive Price & Availability Today!
Calibration: Ask About Our Tiered Calibration Levels
Option & Modules: Confirm Your Requirements or Versions
Repair: Cost & Lead Time Available Upon Request for Service
Repair Evaluation: $150
Share this page: facebook twitter linkedIn