PCI-8513 National Instruments CAN Interface Device | Apex Waves | ImagePCI-8513 National Instruments CAN Interface Device | Apex Waves | ImagePCI-8513 NewPCI-8513 | Legacy, Refurbished and New Surplus
PCI-8513 National Instruments CAN Interface Device | Apex Waves | Image
PCI-8513 National Instruments CAN Interface Device | Apex Waves | Image
PCI-8513 New
PCI-8513 | Legacy, Refurbished and New Surplus

PCI-8513

4.5/5 | 19 ratings

Modular Systems > National Instruments > PCI CAN Interfaces

Part Number PCI-8513
Manufacturer/Brand National Instruments
Description: PCI-8513, 1-Port, CAN Interface Device
In Stock | Ships Today
Fast Quote
Quoted Price
Same Day Calibration Available
2-3 Year Warranty Included
Free Ground Shipping
  Get Pricing

Need an Official Quote?

 

Or speak to a sales representative for additional information:


National Instruments PCI-8513 CAN Interface Device

The PCI8513 (Part Number: 780684-01) comes with 1 port and is a software selectable FD CAN device which has a device simulator called NI CAN. When connecting with NI CAN and the DAQ equipment on a PC, this gives an apparatus to show the concepts of CAN communication, DAQ, and CAN/DAQ management. This instrument simulator comes with an advanced volume creator, a fast CAN line, fast CAN connector, and computerized input switches.

The NI CAN breakout box on the NI PCI-8513 device highlights 14 parallel wired ports for stretching extra CAN gadgets to a NI CAN interface or other CAN arrangement. Seven connectors utilize standard NI CAN D-SUB pinouts for associations with NI CAN links and gadgets. At the same time, there are seven other connectors which are screw-terminal removable connectors for simple associations with exposed wires. The installed control supply applies capacity to the V+ sticks on the bus, which is required for some handsets, and switchable 120 Ω, 60 Ω, or no-end disentangles associations with most CAN gadgets. NI-XNET interfaces highlight installed programming empowered end, which disposes of the requirement for end resistors in CAN or LIN links. NI suggests no-end CAN and LIN links for use with NI-XNET CAN and LIN interfaces. For NI-XNET FlexRay interfaces, utilize 9-stick D-SUB links to associate with ECUs and FlexRay gadgets. The NI CAN to OBD-II link associates a NI fast CAN interface to the standard J1962 indicative connector found in late-show cars for analytic applications.

ModelPCI-8513
ManufacturerNational Instruments
Part Number780684-01
TypeCAN Interface Device
Ports1
TransceiverTJA1054A, TJA1041, AU5790
CAN Physical LayerSoftware-Selectable/FD
Maximum Baud Rate125 kbits/s, 8 Mbit/s, 83.3 kbits/s
Minimum Baud Rate40 kbits/s, 33.3 kbits/s
Trigger Lines7 Input/Output
Clock Lines1 Input/Output
I/O CompatibilityTTL
CAN_H, CAN_L Bus Lines Voltage-27 VDC to +40 VDC
I/O Connector9-Pin Male D-sub
Power Requirements+5 VDC, +3.3 VDC -- 640 mA, 940 mA
Dimensions4.2 in. x 6.6 in.
Weight0.22 lb.
Software DriverNI‑XNET, NI-CAN
Warranty2-3 Year Warranty
PCI-8513 ManualUser Manual and Maintenance Manual Available for Download
PriceContact a sales representative for a quote.

Associated part numbers for the PCI-8513:

198980B-42L, 198980C-41L, 198980C-42L, 198980D-41L, 198980D-42L, 198980E-41L, 198980E-42L, 198980F-42, 198980F-42L, 198980G-41L, 198980G-42L, 198980H-41L, 198980H-42L, 780684-01, 780684-02, 198980A-41L, 198980A-42L, 198980B-41L

National Instruments PCI-8513 Frequently Asked Questions  

 

Question: What driver is used by the NI PCI-8513 interface?

 

Answer: The NI PCI-8513 uses the NI-XNET driver.

 

Question: Can I connect the PCI-8513 with a CAN interface that has a different baud rate?

 

Answer: If you connect the PCI-8513 with a CAN network that runs at a different baud rate, you will get a bus error.

 

Question: What size is the NI PCI-8513 card?

 

Answer: The NI PCI-8513 is a ½ size normal PCI card.

  PCI-8513 PDF Manuals

Driver Downloads for PCI-8513






OS Compatibility:
Win XP 32-bit, Win 7 32-bit, Win 10 32-bit

 Download Version


Why Buy From Apex Waves:

Apex Waves Youtube Video

"The business transaction was super easy and friendly."


"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"


"They were very helpful to get me the test equipment that I need."



Delivery:    
UPS, FedEX and DHL – Free Ground on all orders
Overnight, Next Day Air or Expedited shipping options available
International delivery available
Same day shipping for in-stock on location
Warranty: All of our products are covered by our Apex Waves Warranty.
3 Year Warranty - New Surplus Parts
2 Year Warranty - Refurbished Parts
Returns: No hassle return policy.
Dedicated customer service team.
Payment: Authorize.net Visa Master Card American Express BB&T Better Business Bureau Dun & Bradstreet
Quick Quotes: Receive Price & Availability Today!
Calibration: Ask About Our Tiered Calibration Levels
Option & Modules: Confirm Your Requirements or Versions
Repair: Cost & Lead Time Available Upon Request for Service
Repair Evaluation: $150
Share this page: Facebook Icon Twitter Icon LinkedIn Icon
Common Typos: PSI-8513, PFI-8513, PCI-8T13, PCI-851W, PCI-851R

PCI-8513



Modular Systems > National Instruments > PCI CAN Interfaces

PCI-8513
4.5/5 | 19 ratings

PCI-8513, 1-Port, CAN Interface Device

In Stock | Ships Today
Same Day Calibration Available
2-3 Year Warranty Included
Free Ground Shipping
  Get Pricing

Call now for best pricing
1-800-915-6216

National Instruments PCI-8513 CAN Interface Device

The PCI8513 (Part Number: 780684-01) comes with 1 port and is a software selectable FD CAN device which has a device simulator called NI CAN. When connecting with NI CAN and the DAQ equipment on a PC, this gives an apparatus to show the concepts of CAN communication, DAQ, and CAN/DAQ management. This instrument simulator comes with an advanced volume creator, a fast CAN line, fast CAN connector, and computerized input switches.

The NI CAN breakout box on the NI PCI-8513 device highlights 14 parallel wired ports for stretching extra CAN gadgets to a NI CAN interface or other CAN arrangement. Seven connectors utilize standard NI CAN D-SUB pinouts for associations with NI CAN links and gadgets. At the same time, there are seven other connectors which are screw-terminal removable connectors for simple associations with exposed wires. The installed control supply applies capacity to the V+ sticks on the bus, which is required for some handsets, and switchable 120 Ω, 60 Ω, or no-end disentangles associations with most CAN gadgets. NI-XNET interfaces highlight installed programming empowered end, which disposes of the requirement for end resistors in CAN or LIN links. NI suggests no-end CAN and LIN links for use with NI-XNET CAN and LIN interfaces. For NI-XNET FlexRay interfaces, utilize 9-stick D-SUB links to associate with ECUs and FlexRay gadgets. The NI CAN to OBD-II link associates a NI fast CAN interface to the standard J1962 indicative connector found in late-show cars for analytic applications.

ModelPCI-8513
ManufacturerNational Instruments
Part Number780684-01
TypeCAN Interface Device
Ports1
TransceiverTJA1054A, TJA1041, AU5790
CAN Physical LayerSoftware-Selectable/FD
Maximum Baud Rate125 kbits/s, 8 Mbit/s, 83.3 kbits/s
Minimum Baud Rate40 kbits/s, 33.3 kbits/s
Trigger Lines7 Input/Output
Clock Lines1 Input/Output
I/O CompatibilityTTL
CAN_H, CAN_L Bus Lines Voltage-27 VDC to +40 VDC
I/O Connector9-Pin Male D-sub
Power Requirements+5 VDC, +3.3 VDC -- 640 mA, 940 mA
Dimensions4.2 in. x 6.6 in.
Weight0.22 lb.
Software DriverNI‑XNET, NI-CAN
Warranty2-3 Year Warranty
PCI-8513 ManualUser Manual and Maintenance Manual Available for Download
PriceContact a sales representative for a quote.

National Instruments PCI-8513 Frequently Asked Questions  

 

Question: What driver is used by the NI PCI-8513 interface?

 

Answer: The NI PCI-8513 uses the NI-XNET driver.

 

Question: Can I connect the PCI-8513 with a CAN interface that has a different baud rate?

 

Answer: If you connect the PCI-8513 with a CAN network that runs at a different baud rate, you will get a bus error.

 

Question: What size is the NI PCI-8513 card?

 

Answer: The NI PCI-8513 is a ½ size normal PCI card.

Software & Drivers





OS Compatibility:
Win XP 32-bit, Win 7 32-bit, Win 10 32-bit

 Download Version

Why Buy From Apex Waves

Apex Waves Youtube Video

"The business transaction was super easy and friendly."


"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"


"They were very helpful to get me the test equipment that I need."


Delivery: UPS, FedEX and DHL – Free FedEx Ground on all orders
Overnight, Next Day Air or Expedited shipping options available
International delivery available
Same day shipping for in-stock on location
Warranty: All of our products are covered by our Apex Waves Warranty.
3 Year Warranty - New Surplus Parts
2 Year Warranty - Refurbished Parts
Returns: No hassle return policy.
Dedicated customer service team.
Payment: Authorize.Net paypal visa card master card american express card BB&T Bank better business bureau
Quick Quotes: Receive Price & Availability Today!
Calibration: Ask About Our Tiered Calibration Levels
Option & Modules: Confirm Your Requirements or Versions
Repair: Cost & Lead Time Available Upon Request for Service
Repair Evaluation: $150
Share this page: facebook twitter linkedIn