PXI-4070 National Instruments Digital Multimeter | Apex Waves | ImagePXI-4070 National Instruments Digital Multimeter | Apex Waves | ImagePXI-4070 NewPXI-4070 | Legacy, Refurbished and New Surplus
PXI-4070 National Instruments Digital Multimeter | Apex Waves | Image
PXI-4070 National Instruments Digital Multimeter | Apex Waves | Image
PXI-4070 New
PXI-4070 | Legacy, Refurbished and New Surplus

PXI-4070

4.8/5 | 10 ratings

Meters > National Instruments > NI-407x Series

Part Number PXI-4070
Manufacturer/Brand National Instruments
Description: PXI-4070, 6.5 Digit, PXI Digital Multimeter
In Stock | Ships Today
Fast Quote
Quoted Price
Same Day Calibration Available
2-3 Year Warranty Included
Free Ground Shipping
  Get Pricing

Need an Official Quote?

 

Or speak to a sales representative for additional information:


National Instruments PXI-4070 PXI Digital Multimeter

The NI PXI-4070 (Part Number: 778274-01) 6.5 Digit FlexDMM has high throughput rates, while keeping up precision and stable estimation. With National Instruments restrictive FlexDMM innovation, this DMM gives a completely separated, high-voltage digitizer capable of acquiring waveforms at sampling rates up to 1.8 MS/s at all voltage and current ratings. Utilizing the analysis capabilities available in NI LabVIEW programming, the user can dissect these waveforms in both the time and frequency spaces. The NI PXI-4070 DMM has superior speed, precision, and functionality, making it an excellent fit for use in computerized tests on both the production floor and in R&D applications. 

The PXI 4070 National Instruments can be used with NI-DMM, which is an IVI-consistent driver that accesses the entire functionality of the DMM through a simple-to-utilize application programming interface (API) and is compatible with languages like C/C++, .NET, Visual Basic, LabVIEW, and LabWindows/CVI. This unit also offers a 1.8 MS/s Flexible-Resolution Isolated Digitizer and the possibility to vary the resolution of the FlexDMM from 10 to 23 bits by changing the sampling rate. In addition, the Digital Multimeter includes a one of a kind multi-instrument functionality that limits general framework cost by eradicating the need to buy a different data acquisition device, signal conditioning, fixturing, etc.

The device is coupled with both DC and AC systems. Its DC system has the following features: a range/function change of 100/s, an auto range time of 50 ms, a trigger latency of 2 μs, a maximum trigger rate of 6kHz. Its AC system has the following features: range or function change of 10/s, an auto range time of 250 ms, a trigger latency of μs, and a maximum trigger rate of 1 kHz.

The National Instruments PXI-4070 additionally has a built-in self-calibration feature. The self-calibration or Self-Cal feature enhances preciseness by eradicating errors from temperature changes and long-term drift. Self-Cal guarantees preciseness over the complete 0 to 55 degrees Celsius operating temperature range. In addition, an external calibration every two years helps decrease downtime and maintenance expenses. 

PXI-4070 Maintenance Status has been announced by National Instruments, but the Digital Multimeter will still be available for purchase and repairs by Apex Waves. Additional datasheets and manuals for the PXI-4070 are available under the "Manuals & PDFs" tab.

ModelPXI-4070
ManufacturerNational Instruments
Part Number778274-01
HTS Code8471804000
TypePXI Digital Multimeter
Maximum Sample Rate1.8 MS/s
Digits of Resolution6.5
DC Voltage Range-300 V to 300 V
Dimensions0.8 in. × 5.1 in. × 8.5 in.
Weight12 oz.
WarrantyThree Year Warranty
PXI-4070 ManualUser Manual and Maintenance Manual Available for Download
PriceContact a sales representative for a quote.

Associated part numbers for PXI-4070:

153488A-01, 185828D-01, 185828F-01, 185828G-01, 185828H-01, 185828J-01, 185828K-01, 185828W-02L, 185830F-01, 18634.6, 186346B-01, 186346B-20, 186346C-01, 186346D-01, 186346F-01, 186533A-01, 186553A-01, 187153A-01, 19.1485, 19022.2, 190222D-01, 190222F-01, 190222F-01L, 190222G-01L, 190222H-01L, 190222J-01L, 19148.5, 191485A-01, 191485B-01, 191485C-01, 191485C-04, 191485D-01, 191485D-04, 191485F-01, 191485G-01, 191485H-01L, 191485J-01L, 191485K-01L, 191485L-01L, 191485M-01L, 191485N-01L, 200031A-01, 778274-01, 778274-04

National Instruments PXI-4070 Frequently Asked Questions

 

Question: What is the NI PXI-4070 driver?

Answer: The NI PXI-4070 driver is NI-DMM, DMM Express VI for LabVIEW, and DMM Soft Panel.

 

Question: How long is the suggested warm-up time for the PXI 4070 National Instruments?

Answer: The suggested warm-up time for the PXI 4070 National Instruments is one hour.

 

Question: What is the power consumption of the NI PXI-4070?

Answer: The power consumption of the NI PXI-4070 is <12 W from the PXI backplane.

 

Question: How long is the calibration interval for the National Instruments NI PXI-4070?

Answer: The calibration interval for the National Instruments NI PXI-4070 is two years.

 

Question: What is the maximum trigger rate for the AC system of the PXI-4070?

Answer: The maximum trigger rate is 1 kHz

 

Question: What is the voltage range of the PXI-4070's acquisition system?

Answer: The voltage range is ±100 mV to ±300 V (DC or AC coupled)

  PXI-4070 PDF Manuals

  PXI-4070 Diagrams

Driver Downloads for PXI-4070






OS Compatibility:
Win XP 32-bit, Win 7 32-bit, Win 10 32-bit

 Download Version


Why Buy From Apex Waves:

Apex Waves Youtube Video

"The business transaction was super easy and friendly."


"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"


"They were very helpful to get me the test equipment that I need."



Delivery:    
UPS, FedEX and DHL – Free Ground on all orders
Overnight, Next Day Air or Expedited shipping options available
International delivery available
Same day shipping for in-stock on location
Warranty: All of our products are covered by our Apex Waves Warranty.
3 Year Warranty - New Surplus Parts
2 Year Warranty - Refurbished Parts
Returns: No hassle return policy.
Dedicated customer service team.
Payment: Authorize.net Visa Master Card American Express BB&T Better Business Bureau Dun & Bradstreet
Quick Quotes: Receive Price & Availability Today!
Calibration: Ask About Our Tiered Calibration Levels
Option & Modules: Confirm Your Requirements or Versions
Repair: Cost & Lead Time Available Upon Request for Service
Repair Evaluation: $150
Share this page: Facebook Icon Twitter Icon LinkedIn Icon
Common Typos: PSI-4070, PXJ-4070, PXI-R070, PXI-T070, PXI-40I0

PXI-4070



Meters > National Instruments > NI-407x Series

PXI-4070
4.8/5 | 10 ratings

PXI-4070, 6.5 Digit, PXI Digital Multimeter

In Stock | Ships Today
Same Day Calibration Available
2-3 Year Warranty Included
Free Ground Shipping
  Get Pricing

Call now for best pricing
1-800-915-6216

National Instruments PXI-4070 PXI Digital Multimeter

The NI PXI-4070 (Part Number: 778274-01) 6.5 Digit FlexDMM has high throughput rates, while keeping up precision and stable estimation. With National Instruments restrictive FlexDMM innovation, this DMM gives a completely separated, high-voltage digitizer capable of acquiring waveforms at sampling rates up to 1.8 MS/s at all voltage and current ratings. Utilizing the analysis capabilities available in NI LabVIEW programming, the user can dissect these waveforms in both the time and frequency spaces. The NI PXI-4070 DMM has superior speed, precision, and functionality, making it an excellent fit for use in computerized tests on both the production floor and in R&D applications. 

The PXI 4070 National Instruments can be used with NI-DMM, which is an IVI-consistent driver that accesses the entire functionality of the DMM through a simple-to-utilize application programming interface (API) and is compatible with languages like C/C++, .NET, Visual Basic, LabVIEW, and LabWindows/CVI. This unit also offers a 1.8 MS/s Flexible-Resolution Isolated Digitizer and the possibility to vary the resolution of the FlexDMM from 10 to 23 bits by changing the sampling rate. In addition, the Digital Multimeter includes a one of a kind multi-instrument functionality that limits general framework cost by eradicating the need to buy a different data acquisition device, signal conditioning, fixturing, etc.

The device is coupled with both DC and AC systems. Its DC system has the following features: a range/function change of 100/s, an auto range time of 50 ms, a trigger latency of 2 μs, a maximum trigger rate of 6kHz. Its AC system has the following features: range or function change of 10/s, an auto range time of 250 ms, a trigger latency of μs, and a maximum trigger rate of 1 kHz.

The National Instruments PXI-4070 additionally has a built-in self-calibration feature. The self-calibration or Self-Cal feature enhances preciseness by eradicating errors from temperature changes and long-term drift. Self-Cal guarantees preciseness over the complete 0 to 55 degrees Celsius operating temperature range. In addition, an external calibration every two years helps decrease downtime and maintenance expenses. 

PXI-4070 Maintenance Status has been announced by National Instruments, but the Digital Multimeter will still be available for purchase and repairs by Apex Waves. Additional datasheets and manuals for the PXI-4070 are available under the "Manuals & PDFs" tab.

ModelPXI-4070
ManufacturerNational Instruments
Part Number778274-01
HTS Code8471804000
TypePXI Digital Multimeter
Maximum Sample Rate1.8 MS/s
Digits of Resolution6.5
DC Voltage Range-300 V to 300 V
Dimensions0.8 in. × 5.1 in. × 8.5 in.
Weight12 oz.
WarrantyThree Year Warranty
PXI-4070 ManualUser Manual and Maintenance Manual Available for Download
PriceContact a sales representative for a quote.

National Instruments PXI-4070 Frequently Asked Questions

 

Question: What is the NI PXI-4070 driver?

Answer: The NI PXI-4070 driver is NI-DMM, DMM Express VI for LabVIEW, and DMM Soft Panel.

 

Question: How long is the suggested warm-up time for the PXI 4070 National Instruments?

Answer: The suggested warm-up time for the PXI 4070 National Instruments is one hour.

 

Question: What is the power consumption of the NI PXI-4070?

Answer: The power consumption of the NI PXI-4070 is <12 W from the PXI backplane.

 

Question: How long is the calibration interval for the National Instruments NI PXI-4070?

Answer: The calibration interval for the National Instruments NI PXI-4070 is two years.

 

Question: What is the maximum trigger rate for the AC system of the PXI-4070?

Answer: The maximum trigger rate is 1 kHz

 

Question: What is the voltage range of the PXI-4070's acquisition system?

Answer: The voltage range is ±100 mV to ±300 V (DC or AC coupled)

Software & Drivers





OS Compatibility:
Win XP 32-bit, Win 7 32-bit, Win 10 32-bit

 Download Version

Why Buy From Apex Waves

Apex Waves Youtube Video

"The business transaction was super easy and friendly."


"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"


"They were very helpful to get me the test equipment that I need."


Delivery: UPS, FedEX and DHL – Free FedEx Ground on all orders
Overnight, Next Day Air or Expedited shipping options available
International delivery available
Same day shipping for in-stock on location
Warranty: All of our products are covered by our Apex Waves Warranty.
3 Year Warranty - New Surplus Parts
2 Year Warranty - Refurbished Parts
Returns: No hassle return policy.
Dedicated customer service team.
Payment: Authorize.Net paypal visa card master card american express card BB&T Bank better business bureau
Quick Quotes: Receive Price & Availability Today!
Calibration: Ask About Our Tiered Calibration Levels
Option & Modules: Confirm Your Requirements or Versions
Repair: Cost & Lead Time Available Upon Request for Service
Repair Evaluation: $150
Share this page: facebook twitter linkedIn