PXI-6255 National Instruments Multifunction I/O Module | Apex Waves | ImagePXI-6255 National Instruments Multifunction I/O Module | Apex Waves | ImagePXI-6255 NewPXI-6255 | Legacy, Refurbished and New Surplus
PXI-6255 National Instruments Multifunction I/O Module | Apex Waves | Image
PXI-6255 National Instruments Multifunction I/O Module | Apex Waves | Image
PXI-6255 New
PXI-6255 | Legacy, Refurbished and New Surplus

PXI-6255

4.5/5 | 8 ratings

Modular Systems > National Instruments > M Series

Part Number PXI-6255
Manufacturer/Brand National Instruments
Description: PXI-6255, 80 AI, 24 DIO, 2 AO, PXI Multifunction I/O Module
In Stock | Ships Today
Fast Quote
Quoted Price
Same Day Calibration Available
2-3 Year Warranty Included
Free Ground Shipping
  Get Pricing

Need an Official Quote?

 

Or speak to a sales representative for additional information:


National Instruments PXI-6255 PXI Multifunction I/O Module

With the NI PXI-6255 (Part Number: 779547-01) PXI Multifunction I/O Module, the user can route an inward or outside periodic clock signal (with a known period) to the input counter source. The counter counts the quantity of rising (or falling) edges in the source signal while the pulse in the Gate Signal is active. In pulse width estimations, the counter measures the width of a pulse on its Gate input signal. The user can arrange the counter to quantify the width of high pulses or low pulses on the Gate signal. The device has 80 analog input channels with an input resolution of 16 bits.
The PXI-6255 Multifunction I/O Module is compatible with NI SCC and SCXI signal conditioning platforms, which provide amplification, filtering, and power for any type of sensor. These platforms also comply with the electronic data sheet (TEDS) sensors of the IEEE 1451.4 smart transducer, which provides digital storage for information from the sensor datasheet.

The NI PXI-6255 M Series device can be used with NI LabVIEW SignalExpress interactive measurement software to deliver benchtop measurements to the PC. With LabVIEW SignalExpress interactive configuration-based steps, the user can quickly create design verification tests. The fast acquisition and generation rates of high-speed M Series devices, along with LabVIEW SignalExpress provide on-the-go design analysis. The user can convert their tested and verified LabVIEW SignalExpress projects to LabVIEW applications for immediate DAQ use, thus bridging the gap between test, control, and design applications. The device is equipped with 2 68-pin VHDCI I/O connectors. It has a recommended warm-up time of 15 minutes, and should be externally calibrated at least once in 2 years.

The standard 3U PXI device weighs 8.3 oz. It has recommended operating and storage temperature ranges of 0 ºC to 55 ºC and -20 ºC to 70 ºC respectively, a non-condensing humidity range of 10% RH to 90% RH, operating and non-operating random vibrations of 0.3 grms and 2.4 grms respectively–at a frequency range of 5 to 500 Hz.

PXI-6255 Obsolete Status has been announced by National Instruments, but the module will still be available for purchase and repairs by Apex Waves. 

The PXI-6255 is available to be calibrated. While the recommended calibration period for individual parts varies, most parts should be calibrated either annually or every two years to ensure accuracy. If you need the PXI-6255 calibrated, Apex Waves provides options. We offer high-quality NIST accredited calibrations through a 3rd party, with an average turnaround time of 1 to 2 weeks. When you order the PXI-6255 with us, you can request basic (unaccredited) in-house calibration that will calibrate the part to the manufacturer specifications prior to being shipped. Call or email us today for more information about calibrating the PXI-6255!

ModelPXI-6255 (779547-01)
ManufacturerNational Instruments
SeriesM Series
TypePXI Multifunction I/O Module
Analog Input Channels80
Analog Input Resolution16 bits
DimensionsStandard 3U PXI
Weight8.3 oz.
WarrantyThree Year Warranty
PXI-6255 ManualUser Manual and Maintenance Manual Available for Download
PriceContact a sales representative for a quote.

Associated part numbers for PXI-6255:

193618A-01, 193618B-01, 193618C-01L, 193618D-01L, 779547-01

National Instruments PXI-6255 Frequently Asked Questions

 

Question: What is the maximum working voltage of the NI PXI-6255?

 

Answer: The maximum working voltage of the NI PXI-6255 is 11 V, Measurement Category I.

 

Question: What is the maximum sample rate of the PXI-6255?

 

Answer: The PXI-6255 has a maximum sample rate of 1.25 MS/s for one channel and 750 kS/s for all channels.

 

Question: How many analog triggers does the NI PXI-6255 M Series Module have?

 

Answer: The NI PXI-6255 M Series Module has 1 analog trigger.

 

Question: What are the functions of the analog trigger on the PXI-6255 module?

 

Answer: The PXI-6255 module’s analog trigger functions include: Sample Clock Timebase, Start Trigger, Pause Trigger, Convert Clock, Reference Trigger, and Sample Clock.

  PXI-6255 PDF Manuals

  PXI-6255 Diagrams


Why Buy From Apex Waves:

Apex Waves Youtube Video

"The business transaction was super easy and friendly."


"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"


"They were very helpful to get me the test equipment that I need."



Delivery:    
UPS, FedEX and DHL – Free Ground on all orders
Overnight, Next Day Air or Expedited shipping options available
International delivery available
Same day shipping for in-stock on location
Warranty: All of our products are covered by our Apex Waves Warranty.
3 Year Warranty - New Surplus Parts
2 Year Warranty - Refurbished Parts
Returns: No hassle return policy.
Dedicated customer service team.
Payment: Authorize.net Visa Master Card American Express BB&T Better Business Bureau Dun & Bradstreet
Quick Quotes: Receive Price & Availability Today!
Calibration: Ask About Our Tiered Calibration Levels
Option & Modules: Confirm Your Requirements or Versions
Repair: Cost & Lead Time Available Upon Request for Service
Repair Evaluation: $150
Share this page: Facebook Icon Twitter Icon LinkedIn Icon
Common Typos: PSI-6255, PXO-6255, PXI-U255, PXI-6W55, PXI-62Y5

PXI-6255



Modular Systems > National Instruments > M Series

PXI-6255
4.5/5 | 8 ratings

PXI-6255, 80 AI, 24 DIO, 2 AO, PXI Multifunction I/O Module

In Stock | Ships Today
Same Day Calibration Available
2-3 Year Warranty Included
Free Ground Shipping
  Get Pricing

Call now for best pricing
1-800-915-6216

National Instruments PXI-6255 PXI Multifunction I/O Module

With the NI PXI-6255 (Part Number: 779547-01) PXI Multifunction I/O Module, the user can route an inward or outside periodic clock signal (with a known period) to the input counter source. The counter counts the quantity of rising (or falling) edges in the source signal while the pulse in the Gate Signal is active. In pulse width estimations, the counter measures the width of a pulse on its Gate input signal. The user can arrange the counter to quantify the width of high pulses or low pulses on the Gate signal. The device has 80 analog input channels with an input resolution of 16 bits.
The PXI-6255 Multifunction I/O Module is compatible with NI SCC and SCXI signal conditioning platforms, which provide amplification, filtering, and power for any type of sensor. These platforms also comply with the electronic data sheet (TEDS) sensors of the IEEE 1451.4 smart transducer, which provides digital storage for information from the sensor datasheet.

The NI PXI-6255 M Series device can be used with NI LabVIEW SignalExpress interactive measurement software to deliver benchtop measurements to the PC. With LabVIEW SignalExpress interactive configuration-based steps, the user can quickly create design verification tests. The fast acquisition and generation rates of high-speed M Series devices, along with LabVIEW SignalExpress provide on-the-go design analysis. The user can convert their tested and verified LabVIEW SignalExpress projects to LabVIEW applications for immediate DAQ use, thus bridging the gap between test, control, and design applications. The device is equipped with 2 68-pin VHDCI I/O connectors. It has a recommended warm-up time of 15 minutes, and should be externally calibrated at least once in 2 years.

The standard 3U PXI device weighs 8.3 oz. It has recommended operating and storage temperature ranges of 0 ºC to 55 ºC and -20 ºC to 70 ºC respectively, a non-condensing humidity range of 10% RH to 90% RH, operating and non-operating random vibrations of 0.3 grms and 2.4 grms respectively–at a frequency range of 5 to 500 Hz.

PXI-6255 Obsolete Status has been announced by National Instruments, but the module will still be available for purchase and repairs by Apex Waves. 

The PXI-6255 is available to be calibrated. While the recommended calibration period for individual parts varies, most parts should be calibrated either annually or every two years to ensure accuracy. If you need the PXI-6255 calibrated, Apex Waves provides options. We offer high-quality NIST accredited calibrations through a 3rd party, with an average turnaround time of 1 to 2 weeks. When you order the PXI-6255 with us, you can request basic (unaccredited) in-house calibration that will calibrate the part to the manufacturer specifications prior to being shipped. Call or email us today for more information about calibrating the PXI-6255!

ModelPXI-6255 (779547-01)
ManufacturerNational Instruments
SeriesM Series
TypePXI Multifunction I/O Module
Analog Input Channels80
Analog Input Resolution16 bits
DimensionsStandard 3U PXI
Weight8.3 oz.
WarrantyThree Year Warranty
PXI-6255 ManualUser Manual and Maintenance Manual Available for Download
PriceContact a sales representative for a quote.

National Instruments PXI-6255 Frequently Asked Questions

 

Question: What is the maximum working voltage of the NI PXI-6255?

 

Answer: The maximum working voltage of the NI PXI-6255 is 11 V, Measurement Category I.

 

Question: What is the maximum sample rate of the PXI-6255?

 

Answer: The PXI-6255 has a maximum sample rate of 1.25 MS/s for one channel and 750 kS/s for all channels.

 

Question: How many analog triggers does the NI PXI-6255 M Series Module have?

 

Answer: The NI PXI-6255 M Series Module has 1 analog trigger.

 

Question: What are the functions of the analog trigger on the PXI-6255 module?

 

Answer: The PXI-6255 module’s analog trigger functions include: Sample Clock Timebase, Start Trigger, Pause Trigger, Convert Clock, Reference Trigger, and Sample Clock.

Why Buy From Apex Waves

Apex Waves Youtube Video

"The business transaction was super easy and friendly."


"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"


"They were very helpful to get me the test equipment that I need."


Delivery: UPS, FedEX and DHL – Free FedEx Ground on all orders
Overnight, Next Day Air or Expedited shipping options available
International delivery available
Same day shipping for in-stock on location
Warranty: All of our products are covered by our Apex Waves Warranty.
3 Year Warranty - New Surplus Parts
2 Year Warranty - Refurbished Parts
Returns: No hassle return policy.
Dedicated customer service team.
Payment: Authorize.Net paypal visa card master card american express card BB&T Bank better business bureau
Quick Quotes: Receive Price & Availability Today!
Calibration: Ask About Our Tiered Calibration Levels
Option & Modules: Confirm Your Requirements or Versions
Repair: Cost & Lead Time Available Upon Request for Service
Repair Evaluation: $150
Share this page: facebook twitter linkedIn