PXIe-7972 National Instruments PXI FPGA Module for FlexRIO | Apex Waves | ImagePXIe-7972 National Instruments PXI FPGA Module for FlexRIO | Apex Waves - Wiring Diagram ImagePXIe-7972 NewPXIe-7972 | Legacy, Refurbished and New Surplus
PXIe-7972 National Instruments PXI FPGA Module for FlexRIO | Apex Waves | Image
PXIe-7972 National Instruments PXI FPGA Module for FlexRIO | Apex Waves - Wiring Diagram Image
PXIe-7972 New
PXIe-7972 | Legacy, Refurbished and New Surplus

PXIe-7972

4.8/5 | 18 ratings

Modular Systems > National Instruments > FlexRIO

Part Number PXIe-7972
Manufacturer/Brand National Instruments
Description: PXIe-7972, K325T FPGA, PXI FPGA Module for FlexRIO
Request for Availablility
Fast Quote
Quoted Price
Same Day Calibration Available
2-3 Year Warranty Included
Free Ground Shipping
  Get Pricing

Need an Official Quote?

 

Or speak to a sales representative for additional information:


National Instruments PXIe-7972 PXI FPGA Module for FlexRIO

The K325T FPGA, 1.7 GB/s, 2 GB DRAM PXIe-7972 (Part Number: 782954-01) is an FPGA Module for FlexRIO. For more complex HDL that may utilize multiple clock domains and execute non-concurrently, the CLIP Node offers an interface. Through an XML wrapper, the user can import the HDL into LabVIEW and access it through the I/O axis. It is also possible to utilize the CLIP Node to interface to the NI FlexRIO connector module and the FPGA module locally available DRAM. The CLIPNode executes asynchronously to the LabVIEW block diagram, can support various tickers, and is required for redoing certain highlights of the equipment, such as the connector module interface. This is not the same as the IP Integration Node, which executes in line with the LabVIEW box diagram and can be precisely reproduced with the LabVIEW host simulation.

The NI FlexRIO Instrument Development Library is a gathering of LabVIEW Host and FPGA code intended to give FPGA capacities, such as acquisition engines, DRAM interfaces, and trigger logic, alongside the related host APIs. This code is open and modular, so the user can choose just the parts they need, and it delivers proficient implementation. It can be used to alter the code given in the library, if important, to meet any user’s unique application needs.

The NI PXIe-7972 Example Instrument Driver expands on the NI FlexRIO Instrument Development Library to deliver familiar API and default software FPGA personality for NI 573x digitizer connector modules. It encourages the user to rapidly start taking estimations, change both the LabVIEW Host and FPGA code to suit the user’s application, and gives access to the full capacities of client adjustable equipment instrumentation.

ModelPXIe-7972
Part Number782954-01
ManufacturerNational Instruments
TypePXI FPGA Module for FlexRIO
FPGAKintex-7 325T
FPGA Slices50950
Block RAM (BRAM)16020 kbit
DSP Slices840
Dynamic RAM (DRAM)2 GB
Warranty2-3 Year Warranty
PXIe-7972 ManualUser Manual and Maintenance Manual Available for Download
PriceContact a sales representative for a quote.

Associated part numbers for PXIe-7972:

153956C-02L, 153956D-02L, 153956E-02L, 153956F-02L, 153956G-02L, 153956H-02L, 153956J-02L, 153956K-02L, 153956L-02L, 200563A-01, 782954-01, 783624-01

National Instruments PXIe-7972 Frequently Asked Questions

 

Question: Which operating systems are compatible with the PXIe-7972?

 

Answer: These operating systems will work with the PXIe-7972: Windows 8, Windows 7, Windows Vista, and Windows XP Pro x32 Service Pack 2 or Service Pack 3.

 

Question: What is the value for the single-ended configuration rates on the NI PXIe-7972?

 

Answer: The single-ended configuration rates on the NI PXIe-7972 are 400 Mb/s maximum.

 

Question: How do you configure the PXIe-7972 to accomplish certain FPGA I/O operations on FPGA targets?

 

Answer: The PXIe-7972 can be configured to accomplish certain FPGA I/O operations on FPGA targets with the Invoke Method function, the FPGA I/O Method Node, and the FPGA I/O Node.


Why Buy From Apex Waves:

Apex Waves Youtube Video

"The business transaction was super easy and friendly."


"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"


"They were very helpful to get me the test equipment that I need."



Delivery:    
UPS, FedEX and DHL – Free Ground on all orders
Overnight, Next Day Air or Expedited shipping options available
International delivery available
Same day shipping for in-stock on location
Warranty: All of our products are covered by our Apex Waves Warranty.
3 Year Warranty - New Surplus Parts
2 Year Warranty - Refurbished Parts
Returns: No hassle return policy.
Dedicated customer service team.
Payment: Authorize.net Visa Master Card American Express BB&T Better Business Bureau Dun & Bradstreet
Quick Quotes: Receive Price & Availability Today!
Calibration: Ask About Our Tiered Calibration Levels
Option & Modules: Confirm Your Requirements or Versions
Repair: Cost & Lead Time Available Upon Request for Service
Repair Evaluation: $150
Share this page: Facebook Icon Twitter Icon LinkedIn Icon
Common Typos: PZIE-7972, PDIE-7972, PXLE-7972, PXIE-Y972, PXIE-U972

PXIe-7972



Modular Systems > National Instruments > FlexRIO

PXIe-7972
4.8/5 | 18 ratings

PXIe-7972, K325T FPGA, PXI FPGA Module for FlexRIO

Request for Availablility
Same Day Calibration Available
2-3 Year Warranty Included
Free Ground Shipping
  Get Pricing

Call now for best pricing
1-800-915-6216

National Instruments PXIe-7972 PXI FPGA Module for FlexRIO

The K325T FPGA, 1.7 GB/s, 2 GB DRAM PXIe-7972 (Part Number: 782954-01) is an FPGA Module for FlexRIO. For more complex HDL that may utilize multiple clock domains and execute non-concurrently, the CLIP Node offers an interface. Through an XML wrapper, the user can import the HDL into LabVIEW and access it through the I/O axis. It is also possible to utilize the CLIP Node to interface to the NI FlexRIO connector module and the FPGA module locally available DRAM. The CLIPNode executes asynchronously to the LabVIEW block diagram, can support various tickers, and is required for redoing certain highlights of the equipment, such as the connector module interface. This is not the same as the IP Integration Node, which executes in line with the LabVIEW box diagram and can be precisely reproduced with the LabVIEW host simulation.

The NI FlexRIO Instrument Development Library is a gathering of LabVIEW Host and FPGA code intended to give FPGA capacities, such as acquisition engines, DRAM interfaces, and trigger logic, alongside the related host APIs. This code is open and modular, so the user can choose just the parts they need, and it delivers proficient implementation. It can be used to alter the code given in the library, if important, to meet any user’s unique application needs.

The NI PXIe-7972 Example Instrument Driver expands on the NI FlexRIO Instrument Development Library to deliver familiar API and default software FPGA personality for NI 573x digitizer connector modules. It encourages the user to rapidly start taking estimations, change both the LabVIEW Host and FPGA code to suit the user’s application, and gives access to the full capacities of client adjustable equipment instrumentation.

ModelPXIe-7972
Part Number782954-01
ManufacturerNational Instruments
TypePXI FPGA Module for FlexRIO
FPGAKintex-7 325T
FPGA Slices50950
Block RAM (BRAM)16020 kbit
DSP Slices840
Dynamic RAM (DRAM)2 GB
Warranty2-3 Year Warranty
PXIe-7972 ManualUser Manual and Maintenance Manual Available for Download
PriceContact a sales representative for a quote.

National Instruments PXIe-7972 Frequently Asked Questions

 

Question: Which operating systems are compatible with the PXIe-7972?

 

Answer: These operating systems will work with the PXIe-7972: Windows 8, Windows 7, Windows Vista, and Windows XP Pro x32 Service Pack 2 or Service Pack 3.

 

Question: What is the value for the single-ended configuration rates on the NI PXIe-7972?

 

Answer: The single-ended configuration rates on the NI PXIe-7972 are 400 Mb/s maximum.

 

Question: How do you configure the PXIe-7972 to accomplish certain FPGA I/O operations on FPGA targets?

 

Answer: The PXIe-7972 can be configured to accomplish certain FPGA I/O operations on FPGA targets with the Invoke Method function, the FPGA I/O Method Node, and the FPGA I/O Node.

Why Buy From Apex Waves

Apex Waves Youtube Video

"The business transaction was super easy and friendly."


"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"


"They were very helpful to get me the test equipment that I need."


Delivery: UPS, FedEX and DHL – Free FedEx Ground on all orders
Overnight, Next Day Air or Expedited shipping options available
International delivery available
Same day shipping for in-stock on location
Warranty: All of our products are covered by our Apex Waves Warranty.
3 Year Warranty - New Surplus Parts
2 Year Warranty - Refurbished Parts
Returns: No hassle return policy.
Dedicated customer service team.
Payment: Authorize.Net paypal visa card master card american express card BB&T Bank better business bureau
Quick Quotes: Receive Price & Availability Today!
Calibration: Ask About Our Tiered Calibration Levels
Option & Modules: Confirm Your Requirements or Versions
Repair: Cost & Lead Time Available Upon Request for Service
Repair Evaluation: $150
Share this page: facebook twitter linkedIn