SCC-A10 National Instruments Voltage Attenuator Module | Apex Waves | ImageSCC-A10 National Instruments Voltage Attenuator Module | Apex Waves | ImageSCC-A10 NewSCC-A10 | Legacy, Refurbished and New Surplus
SCC-A10 National Instruments Voltage Attenuator Module | Apex Waves | Image
SCC-A10 National Instruments Voltage Attenuator Module | Apex Waves | Image
SCC-A10 New
SCC-A10 | Legacy, Refurbished and New Surplus

SCC-A10

4.7/5 | 15 ratings

Modular Systems > National Instruments > SCC

Part Number SCC-A10
Manufacturer/Brand National Instruments
Description: SCC-A10, 2 DIFF Input Channels, Voltage Attenuator Module
In Stock | Ships Today
Fast Quote
Quoted Price
Same Day Calibration Available
2-3 Year Warranty Included
Free Ground Shipping
  Get Pricing

Need an Official Quote?

 

Or speak to a sales representative for additional information:


National Instruments SCC-A10 Voltage Attenuator Module

The SCC-A10 (Part Number: 777459-06) is a Voltage Attenuator Module manufactured by National Instruments. The instrument comes with the capability to attenuate voltage by a factor of 10. This model is equipped with a combination of valuable features and performance capabilities. There are two input channels with a differential instrumentation buffer. The input voltage range is ± 60 VDC, while the input impedance is one mega ohm. It has a bandwidth of 10 kHz. The minimum value for common-mode rejection ratio is 60 DB. These specifications enable the user to fulfill various testing requirements. The device has an analog power requirement of 100 mW max, 3.2 mA max at +15 V and -15 V, and a digital power requirement of 0.0 mA. To setup the SCC-A10, a couple of hardware are required such as a SCC-68 or SC-2345/2350, one or more SCC-A10, a 68-pin E/M series DAQ device, among others.

The National Instruments SCC-A10 Voltage Attenuator Module incorporates the E/M series DAQ. The instrument comes with amazing dynamic response capabilities. The built-in bias resistance offers a high impedance, which enables the user to connect floating or ground-referenced inputs and does not require any external bias resistance. The instrument also comes with a useful feature for protection against overvoltage, as well as a feature to protect DAQ systems for input signals up to 60 VDC. The National Instruments SCC-A10 Voltage Attenuator Module supports cascading for other SCC modules, which further enhances the operational capabilities of the instrument. The device is equipped with one 20-pin right-angle male connector and one 4-pin screw terminal I/O connector.

The National Instruments SCC-A10 measures 3.55 W x 7.93 L x 1.87 D centimeters in physical dimensions, and weighs 29 grams. The instrument has the operational temperature range from 0 to 50 degrees Celsius, and a storage temperature range of –20 to 70 °C. The NI SCC-A10 Voltage Attenuator Module also fulfills standard safety specifications, which includes IEC 61010-1, EN 61010-1, and many others. The instrument supports electromagnetic compatibility and is recommended to be operated with shielded cabling. The NI device is run using the latest version of the NI-DAQmx software.

ModelSCC-A10, 777459-06
ManufacturerNational Instruments
TypeVoltage Attenuator Module
Input Channels2 DIFF
Input Range±60 VDC
Input Impedance1 MΩ (powered on or off)
Bandwidth10 kHz
WarrantyThree Year Warranty
SCC-A10 ManualUser Manual and Maintenance Manual Available for Download
PriceContact a sales representative for a quote.

Associated part numbers for SCC-A10:

183725B-01, 183725C-01, 777459-06

National Instruments SCC-A10 Frequently Asked Questions

 

Question: Does the SCC-A10 include high-impedance bias resistors?

 

Answer: The SCC-A10 includes high-impedance bias resistors to enable you to connect floating or ground reference inputs without adding external bias resistors.

 

Question: Does the SCC A10 provide overvoltage protection?

 

Answer: The SCC A10 provides overvoltage protection for your DAQ system.

 

Question: Are you able to cascade the NI SCC-A10 with other SCC modules?

 

Answer: Yes, you can cascade the NI SCC-A10 with other SCC modules.

 

Question: What type of input socket can the SCC-A10 be plugged into?

 

Answer: The SCC-A10 can be plugged into any analog input socket on the SC-2345, SC-2350, or SCC-68, depending on which DAQ device channels receive the SCC-A10 signals.

  SCC-A10 PDF Manuals


Why Buy From Apex Waves:

Apex Waves Youtube Video

"The business transaction was super easy and friendly."


"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"


"They were very helpful to get me the test equipment that I need."



Delivery:    
UPS, FedEX and DHL – Free Ground on all orders
Overnight, Next Day Air or Expedited shipping options available
International delivery available
Same day shipping for in-stock on location
Warranty: All of our products are covered by our Apex Waves Warranty.
3 Year Warranty - New Surplus Parts
2 Year Warranty - Refurbished Parts
Returns: No hassle return policy.
Dedicated customer service team.
Payment: Authorize.net Visa Master Card American Express BB&T Better Business Bureau Dun & Bradstreet
Quick Quotes: Receive Price & Availability Today!
Calibration: Ask About Our Tiered Calibration Levels
Option & Modules: Confirm Your Requirements or Versions
Repair: Cost & Lead Time Available Upon Request for Service
Repair Evaluation: $150
Share this page: Facebook Icon Twitter Icon LinkedIn Icon
Common Typos: QCC-A10, SSC-A10, SDC-A10, SCS-A10, SCC-Z10

SCC-A10



Modular Systems > National Instruments > SCC

SCC-A10
4.7/5 | 15 ratings

SCC-A10, 2 DIFF Input Channels, Voltage Attenuator Module

In Stock | Ships Today
Same Day Calibration Available
2-3 Year Warranty Included
Free Ground Shipping
  Get Pricing

Call now for best pricing
1-800-915-6216

National Instruments SCC-A10 Voltage Attenuator Module

The SCC-A10 (Part Number: 777459-06) is a Voltage Attenuator Module manufactured by National Instruments. The instrument comes with the capability to attenuate voltage by a factor of 10. This model is equipped with a combination of valuable features and performance capabilities. There are two input channels with a differential instrumentation buffer. The input voltage range is ± 60 VDC, while the input impedance is one mega ohm. It has a bandwidth of 10 kHz. The minimum value for common-mode rejection ratio is 60 DB. These specifications enable the user to fulfill various testing requirements. The device has an analog power requirement of 100 mW max, 3.2 mA max at +15 V and -15 V, and a digital power requirement of 0.0 mA. To setup the SCC-A10, a couple of hardware are required such as a SCC-68 or SC-2345/2350, one or more SCC-A10, a 68-pin E/M series DAQ device, among others.

The National Instruments SCC-A10 Voltage Attenuator Module incorporates the E/M series DAQ. The instrument comes with amazing dynamic response capabilities. The built-in bias resistance offers a high impedance, which enables the user to connect floating or ground-referenced inputs and does not require any external bias resistance. The instrument also comes with a useful feature for protection against overvoltage, as well as a feature to protect DAQ systems for input signals up to 60 VDC. The National Instruments SCC-A10 Voltage Attenuator Module supports cascading for other SCC modules, which further enhances the operational capabilities of the instrument. The device is equipped with one 20-pin right-angle male connector and one 4-pin screw terminal I/O connector.

The National Instruments SCC-A10 measures 3.55 W x 7.93 L x 1.87 D centimeters in physical dimensions, and weighs 29 grams. The instrument has the operational temperature range from 0 to 50 degrees Celsius, and a storage temperature range of –20 to 70 °C. The NI SCC-A10 Voltage Attenuator Module also fulfills standard safety specifications, which includes IEC 61010-1, EN 61010-1, and many others. The instrument supports electromagnetic compatibility and is recommended to be operated with shielded cabling. The NI device is run using the latest version of the NI-DAQmx software.

ModelSCC-A10, 777459-06
ManufacturerNational Instruments
TypeVoltage Attenuator Module
Input Channels2 DIFF
Input Range±60 VDC
Input Impedance1 MΩ (powered on or off)
Bandwidth10 kHz
WarrantyThree Year Warranty
SCC-A10 ManualUser Manual and Maintenance Manual Available for Download
PriceContact a sales representative for a quote.

National Instruments SCC-A10 Frequently Asked Questions

 

Question: Does the SCC-A10 include high-impedance bias resistors?

 

Answer: The SCC-A10 includes high-impedance bias resistors to enable you to connect floating or ground reference inputs without adding external bias resistors.

 

Question: Does the SCC A10 provide overvoltage protection?

 

Answer: The SCC A10 provides overvoltage protection for your DAQ system.

 

Question: Are you able to cascade the NI SCC-A10 with other SCC modules?

 

Answer: Yes, you can cascade the NI SCC-A10 with other SCC modules.

 

Question: What type of input socket can the SCC-A10 be plugged into?

 

Answer: The SCC-A10 can be plugged into any analog input socket on the SC-2345, SC-2350, or SCC-68, depending on which DAQ device channels receive the SCC-A10 signals.

Why Buy From Apex Waves

Apex Waves Youtube Video

"The business transaction was super easy and friendly."


"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"


"They were very helpful to get me the test equipment that I need."


Delivery: UPS, FedEX and DHL – Free FedEx Ground on all orders
Overnight, Next Day Air or Expedited shipping options available
International delivery available
Same day shipping for in-stock on location
Warranty: All of our products are covered by our Apex Waves Warranty.
3 Year Warranty - New Surplus Parts
2 Year Warranty - Refurbished Parts
Returns: No hassle return policy.
Dedicated customer service team.
Payment: Authorize.Net paypal visa card master card american express card BB&T Bank better business bureau
Quick Quotes: Receive Price & Availability Today!
Calibration: Ask About Our Tiered Calibration Levels
Option & Modules: Confirm Your Requirements or Versions
Repair: Cost & Lead Time Available Upon Request for Service
Repair Evaluation: $150
Share this page: facebook twitter linkedIn