SCC-AI06 National Instruments Isolated Analog Input Module | Apex Waves | ImageSCC-AI06 National Instruments Isolated Analog Input Module | Apex Waves - Wiring Diagram ImageSCC-AI06 NewSCC-AI06 | Legacy, Refurbished and New Surplus
SCC-AI06 National Instruments Isolated Analog Input Module | Apex Waves | Image
SCC-AI06 National Instruments Isolated Analog Input Module | Apex Waves - Wiring Diagram Image
SCC-AI06 New
SCC-AI06 | Legacy, Refurbished and New Surplus

SCC-AI06

4.6/5 | 13 ratings

Modular Systems > National Instruments > SCC

Part Number SCC-AI06
Manufacturer/Brand National Instruments
Description: SCC-AI06, 2-Channel, 10 kHz, Isolated Analog Input Module
In Stock | Ships in 5-10 Days
(expedited shipping options available)
Fast Quote
Quoted Price
Same Day Calibration Available
2-3 Year Warranty Included
Free Ground Shipping
  Get Pricing

Need an Official Quote?

 

Or speak to a sales representative for additional information:


National Instruments SCC-AI06 Isolated Analog Input Module

The National Instruments SCC-AI06 (Part Number: 777459-25) is an Isolated Analog Input Module that can extract a generally low-amplitude input signal from a high-common-mode voltage, so the E/M Series DAQ device can quantify the input signal. They additionally amplify and filter the input signal, resulting in higher estimation resolution and precision. This model has a gain of 100, a bandwidth of 10 kHz, an input range of ±100 mV, and an output range of ±10 V.

Each screw terminal on the NI SCC-AI06 is marked by a pin number. Pins 1 and 2 frame a channel directed to the E/M Series DAQ channel X+8. Pins 3 and 4 form a channel directed to the E/M Series DAQ channel X, where X is 0 to 7 depending on the socket where you connect the module. The SCC-AI06 gives channel-to-ground and module-to-module isolation only. It does not offer isolation between the two channels of the NI SCC-AI06. Since the two channels must have a similar reference voltage, pins 1 and 3 are associated together inside. The NI device is equipped with one 20-pin right-angle male connector and one removable 4-pin screw terminal.

If the user arranged the National Instruments SCC-AI06 by utilizing Measurement and Automation Explorer (MAX) and is utilizing NI-DAQmx, the voltage reading received from the E/M Series DAQ device represents the voltage scaling impact of the SCC-AI06. Otherwise, since the voltage estimation from the E/M Series DAQ device is scaled by the increase, the user should divide the voltage reading returned by the E/M Series DAQ device by this gain to find the correct input voltage. The module has an analog power requirement of up to 410 mW, and a digital power requirement of 650 mW maximum.

The SCC-AI06 weighs 1.0 oz, and has a screw terminal wire gauge measuring 24 to 12 AWG. The device has a recommended operating temperature range of 0 to 50 °C, a storage temperature range of –20 to 70 °C, and a non-condensing relative humidity range of 10 to 90%. The DAQ device is designed to comply with the following electrical safety standards: IEC 61010-1, EN 61010-1, UL 61010-1, and CSA 61010-1.

ModelSCC-AI06, 777459-25
ManufacturerNational Instruments
SeriesSCC
TypeIsolated Analog Input Module
Input Range±100 mV
Output Range±10 V
Gain100
WarrantyThree Year Warranty
SCC-AI06 ManualUser Manual and Maintenance Manual Available for Download
PriceContact a sales representative for a quote.

National Instruments SCC-AI06 Frequently Asked Questions

 

Question: What is the settling time of the thermocouple on the SCC-AI06?

 

Answer: The settling time of the thermocouple on the SCC-AI06 will depend on the size of the thermocouple wires and if there is insulation.

 

Question: What type of external power supply can I use with the SCC AI06?

 

Answer: The SCC AI06 does not need external power.

 

Question: What software is required for running the NI SCC-AI06?

 

Answer: For the NI SCC-AI06, you need either LabVIEW, LabWindows™/CVI™, LabVIEW SignalExpress, Measurement Studio, Visual C++, or Visual Basic.

  SCC-AI06 PDF Manuals


Why Buy From Apex Waves:

Apex Waves Youtube Video

"The business transaction was super easy and friendly."


"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"


"They were very helpful to get me the test equipment that I need."



Delivery:    
UPS, FedEX and DHL – Free Ground on all orders
Overnight, Next Day Air or Expedited shipping options available
International delivery available
Same day shipping for in-stock on location
Warranty: All of our products are covered by our Apex Waves Warranty.
3 Year Warranty - New Surplus Parts
2 Year Warranty - Refurbished Parts
Returns: No hassle return policy.
Dedicated customer service team.
Payment: Authorize.net Visa Master Card American Express BB&T Better Business Bureau Dun & Bradstreet
Quick Quotes: Receive Price & Availability Today!
Calibration: Ask About Our Tiered Calibration Levels
Option & Modules: Confirm Your Requirements or Versions
Repair: Cost & Lead Time Available Upon Request for Service
Repair Evaluation: $150
Share this page: Facebook Icon Twitter Icon LinkedIn Icon
Common Typos: SCX-AI06, SCC-QI06, SCC-AK06, SCC-AIO6, SCC-AI0Y

SCC-AI06



Modular Systems > National Instruments > SCC

SCC-AI06
4.6/5 | 13 ratings

SCC-AI06, 2-Channel, 10 kHz, Isolated Analog Input Module

In Stock | Ships in 5-10 Days
(expedited shipping options available)
Same Day Calibration Available
2-3 Year Warranty Included
Free Ground Shipping
  Get Pricing

Call now for best pricing
1-800-915-6216

National Instruments SCC-AI06 Isolated Analog Input Module

The National Instruments SCC-AI06 (Part Number: 777459-25) is an Isolated Analog Input Module that can extract a generally low-amplitude input signal from a high-common-mode voltage, so the E/M Series DAQ device can quantify the input signal. They additionally amplify and filter the input signal, resulting in higher estimation resolution and precision. This model has a gain of 100, a bandwidth of 10 kHz, an input range of ±100 mV, and an output range of ±10 V.

Each screw terminal on the NI SCC-AI06 is marked by a pin number. Pins 1 and 2 frame a channel directed to the E/M Series DAQ channel X+8. Pins 3 and 4 form a channel directed to the E/M Series DAQ channel X, where X is 0 to 7 depending on the socket where you connect the module. The SCC-AI06 gives channel-to-ground and module-to-module isolation only. It does not offer isolation between the two channels of the NI SCC-AI06. Since the two channels must have a similar reference voltage, pins 1 and 3 are associated together inside. The NI device is equipped with one 20-pin right-angle male connector and one removable 4-pin screw terminal.

If the user arranged the National Instruments SCC-AI06 by utilizing Measurement and Automation Explorer (MAX) and is utilizing NI-DAQmx, the voltage reading received from the E/M Series DAQ device represents the voltage scaling impact of the SCC-AI06. Otherwise, since the voltage estimation from the E/M Series DAQ device is scaled by the increase, the user should divide the voltage reading returned by the E/M Series DAQ device by this gain to find the correct input voltage. The module has an analog power requirement of up to 410 mW, and a digital power requirement of 650 mW maximum.

The SCC-AI06 weighs 1.0 oz, and has a screw terminal wire gauge measuring 24 to 12 AWG. The device has a recommended operating temperature range of 0 to 50 °C, a storage temperature range of –20 to 70 °C, and a non-condensing relative humidity range of 10 to 90%. The DAQ device is designed to comply with the following electrical safety standards: IEC 61010-1, EN 61010-1, UL 61010-1, and CSA 61010-1.

ModelSCC-AI06, 777459-25
ManufacturerNational Instruments
SeriesSCC
TypeIsolated Analog Input Module
Input Range±100 mV
Output Range±10 V
Gain100
WarrantyThree Year Warranty
SCC-AI06 ManualUser Manual and Maintenance Manual Available for Download
PriceContact a sales representative for a quote.

National Instruments SCC-AI06 Frequently Asked Questions

 

Question: What is the settling time of the thermocouple on the SCC-AI06?

 

Answer: The settling time of the thermocouple on the SCC-AI06 will depend on the size of the thermocouple wires and if there is insulation.

 

Question: What type of external power supply can I use with the SCC AI06?

 

Answer: The SCC AI06 does not need external power.

 

Question: What software is required for running the NI SCC-AI06?

 

Answer: For the NI SCC-AI06, you need either LabVIEW, LabWindows™/CVI™, LabVIEW SignalExpress, Measurement Studio, Visual C++, or Visual Basic.

Why Buy From Apex Waves

Apex Waves Youtube Video

"The business transaction was super easy and friendly."


"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"


"They were very helpful to get me the test equipment that I need."


Delivery: UPS, FedEX and DHL – Free FedEx Ground on all orders
Overnight, Next Day Air or Expedited shipping options available
International delivery available
Same day shipping for in-stock on location
Warranty: All of our products are covered by our Apex Waves Warranty.
3 Year Warranty - New Surplus Parts
2 Year Warranty - Refurbished Parts
Returns: No hassle return policy.
Dedicated customer service team.
Payment: Authorize.Net paypal visa card master card american express card BB&T Bank better business bureau
Quick Quotes: Receive Price & Availability Today!
Calibration: Ask About Our Tiered Calibration Levels
Option & Modules: Confirm Your Requirements or Versions
Repair: Cost & Lead Time Available Upon Request for Service
Repair Evaluation: $150
Share this page: facebook twitter linkedIn