SCXI-1112 National Instruments Thermocouple Input Module | Apex Waves | ImageSCXI-1112 National Instruments Thermocouple Input Module | Apex Waves | ImageSCXI-1112 NewSCXI-1112 | Legacy, Refurbished and New Surplus
SCXI-1112 National Instruments Thermocouple Input Module | Apex Waves | Image
SCXI-1112 National Instruments Thermocouple Input Module | Apex Waves | Image
SCXI-1112 New
SCXI-1112 | Legacy, Refurbished and New Surplus

SCXI-1112

4.8/5 | 15 ratings

Modular Systems > National Instruments > SCXI

Part Number SCXI-1112
Manufacturer/Brand National Instruments
Description: SCXI-1112, 8 Differential Channels, ±100 mV Input Signal, Thermocouple Input Module
In Stock | Ships Today
Fast Quote
Quoted Price
Same Day Calibration Available
2-3 Year Warranty Included
Free Ground Shipping
  Get Pricing

Need an Official Quote?

 

Or speak to a sales representative for additional information:


National Instruments SCXI-1112 Thermocouple Input Module

The NI SCXI-1112 (Part Number: 776572-12) is a Direct-Connect Thermocouple Amplifier Module. This module is featured with 8 channels and is designed to amplify and filter signals generated from a thermocouple. On each of its eight channels, there is a 3-pole lowpass filter featured with a 2 Hz cutoff frequency capable of rejecting 60 Hz noise. In the NI SCXI-1112, each channel also has an amplifier with 100 fixed gain. With this module, the user can multiplex the inputs of the SCXI-1112 to a single output, driving a single DAQ device channel.

This module comes with an onboard voltage reference. Thus, the user can have it calibrated and auto-zeroed easily. The same auto-zeroing mechanism or circuitry can also be used for the removal of offset voltages. The NI SCXI-1112 is created for use with National Instruments MIO devices from the E series or with the SCXI-1200 modules. Several NI SCXI-1112 modules can also be multiplexed into a single channel, significantly increasing the number of analog inputs.

The SCXI-1112 is run using the NIDAQmx driver software driver which can be programmed using application development environments (ADEs) such as LabVIEW, LabWindows/CVI, ComponentWorks, or VirtualBench. Using any of the above ADEs greatly speeds up the development time.

The NI SCXI-1112 comes with an input signal range of ±100 mV. In normal powered on mode, the amplifier operates with an input impedance of >1 GΩ. However, in overload or powered off states the input impedance remains around 10 kΩ. This module has 2 Hz bandwidth. This module comes with a 96-pin male DIN C connector on its front panel and a 50-pin male ribbon cable connector is provided on the rear panel. The SCXI-1112 module requires 15 mA max power to operate normally.

The NI device measures 4.54 x 10.75 in. in physical dimensions. It has recommended operating and storage temperature ranges of 0 to 50 °C and –55 to 150 °C respectively, and a non-condensing relative humidity relative range of 5 to 90%.

SCXI-1112 End of Life Status has been announced by National Instruments, but the module will still be available for purchase and repairs by Apex Waves. 

The SCXI-1112 is available to be calibrated. While the recommended calibration period for individual parts varies, most parts should be calibrated either annually or every two years to ensure accuracy. If you need the SCXI-1112 calibrated, Apex Waves provides options. We offer high-quality NIST accredited calibrations through a 3rd party, with an average turnaround time of 1 to 2 weeks. When you order the SCXI-1112 with us, you can request basic (unaccredited) in-house calibration that will calibrate the part to the manufacturer specifications prior to being shipped. Call or email us today for more information about calibrating the SCXI-1112!

ModelSCXI-1112, 776572-12
ManufacturerNational Instruments
SeriesSCXI
TypeThermocouple Input Module
Channels8 Differential
Input Signal Ranges±100 mV
Bandwidth2 Hz
WarrantyThree Year Warranty
SCXI-1112 ManualUser Manual and Maintenance Manual Available for Download
PriceContact a sales representative for a quote.

Associated part numbers for SCXI-1112:

186215A-01, 186215B-01, 186215C-01, 186215D-01, 186248B-01, 776572-12

National Instruments SCXI-1112 Frequently Asked Questions

 

Question: What is the maximum working voltage of the SCXI-1112?

 

Answer: The maximum working voltage of the SCXI-1112 is within ±10 V of CGND for each input 

 

Question: What is the recommended warm-up time for the SCXI-1112

 

Answer: The recommended warm up time for the SCXI-1112 is 20 minutes. 

 

Question: What are the offset and gain temperature coefficients of the SCXI-1112

 

Answer: The SCXI-1112 has an offset temp coefficient of 1 µV/°C, and a gain temp coefficient of 10 ppm/°C

  SCXI-1112 PDF Manuals

Driver Downloads for SCXI-1112






OS Compatibility:
Win XP 32-bit, Win 7 32-bit, Win 10 32-bit

 Download Version


Why Buy From Apex Waves:

Apex Waves Youtube Video

"The business transaction was super easy and friendly."


"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"


"They were very helpful to get me the test equipment that I need."



Delivery:    
UPS, FedEX and DHL – Free Ground on all orders
Overnight, Next Day Air or Expedited shipping options available
International delivery available
Same day shipping for in-stock on location
Warranty: All of our products are covered by our Apex Waves Warranty.
3 Year Warranty - New Surplus Parts
2 Year Warranty - Refurbished Parts
Returns: No hassle return policy.
Dedicated customer service team.
Payment: Authorize.net Visa Master Card American Express BB&T Better Business Bureau Dun & Bradstreet
Quick Quotes: Receive Price & Availability Today!
Calibration: Ask About Our Tiered Calibration Levels
Option & Modules: Confirm Your Requirements or Versions
Repair: Cost & Lead Time Available Upon Request for Service
Repair Evaluation: $150
Share this page: Facebook Icon Twitter Icon LinkedIn Icon
Common Typos: QCXI-1112, ECXI-1112, ZCXI-1112, SCXI-1W12, SCXI-111Q

SCXI-1112



Modular Systems > National Instruments > SCXI

SCXI-1112
4.8/5 | 15 ratings

SCXI-1112, 8 Differential Channels, ±100 mV Input Signal, Thermocouple Input Module

In Stock | Ships Today
Same Day Calibration Available
2-3 Year Warranty Included
Free Ground Shipping
  Get Pricing

Call now for best pricing
1-800-915-6216

National Instruments SCXI-1112 Thermocouple Input Module

The NI SCXI-1112 (Part Number: 776572-12) is a Direct-Connect Thermocouple Amplifier Module. This module is featured with 8 channels and is designed to amplify and filter signals generated from a thermocouple. On each of its eight channels, there is a 3-pole lowpass filter featured with a 2 Hz cutoff frequency capable of rejecting 60 Hz noise. In the NI SCXI-1112, each channel also has an amplifier with 100 fixed gain. With this module, the user can multiplex the inputs of the SCXI-1112 to a single output, driving a single DAQ device channel.

This module comes with an onboard voltage reference. Thus, the user can have it calibrated and auto-zeroed easily. The same auto-zeroing mechanism or circuitry can also be used for the removal of offset voltages. The NI SCXI-1112 is created for use with National Instruments MIO devices from the E series or with the SCXI-1200 modules. Several NI SCXI-1112 modules can also be multiplexed into a single channel, significantly increasing the number of analog inputs.

The SCXI-1112 is run using the NIDAQmx driver software driver which can be programmed using application development environments (ADEs) such as LabVIEW, LabWindows/CVI, ComponentWorks, or VirtualBench. Using any of the above ADEs greatly speeds up the development time.

The NI SCXI-1112 comes with an input signal range of ±100 mV. In normal powered on mode, the amplifier operates with an input impedance of >1 GΩ. However, in overload or powered off states the input impedance remains around 10 kΩ. This module has 2 Hz bandwidth. This module comes with a 96-pin male DIN C connector on its front panel and a 50-pin male ribbon cable connector is provided on the rear panel. The SCXI-1112 module requires 15 mA max power to operate normally.

The NI device measures 4.54 x 10.75 in. in physical dimensions. It has recommended operating and storage temperature ranges of 0 to 50 °C and –55 to 150 °C respectively, and a non-condensing relative humidity relative range of 5 to 90%.

SCXI-1112 End of Life Status has been announced by National Instruments, but the module will still be available for purchase and repairs by Apex Waves. 

The SCXI-1112 is available to be calibrated. While the recommended calibration period for individual parts varies, most parts should be calibrated either annually or every two years to ensure accuracy. If you need the SCXI-1112 calibrated, Apex Waves provides options. We offer high-quality NIST accredited calibrations through a 3rd party, with an average turnaround time of 1 to 2 weeks. When you order the SCXI-1112 with us, you can request basic (unaccredited) in-house calibration that will calibrate the part to the manufacturer specifications prior to being shipped. Call or email us today for more information about calibrating the SCXI-1112!

ModelSCXI-1112, 776572-12
ManufacturerNational Instruments
SeriesSCXI
TypeThermocouple Input Module
Channels8 Differential
Input Signal Ranges±100 mV
Bandwidth2 Hz
WarrantyThree Year Warranty
SCXI-1112 ManualUser Manual and Maintenance Manual Available for Download
PriceContact a sales representative for a quote.

National Instruments SCXI-1112 Frequently Asked Questions

 

Question: What is the maximum working voltage of the SCXI-1112?

 

Answer: The maximum working voltage of the SCXI-1112 is within ±10 V of CGND for each input 

 

Question: What is the recommended warm-up time for the SCXI-1112

 

Answer: The recommended warm up time for the SCXI-1112 is 20 minutes. 

 

Question: What are the offset and gain temperature coefficients of the SCXI-1112

 

Answer: The SCXI-1112 has an offset temp coefficient of 1 µV/°C, and a gain temp coefficient of 10 ppm/°C

Software & Drivers





OS Compatibility:
Win XP 32-bit, Win 7 32-bit, Win 10 32-bit

 Download Version

Why Buy From Apex Waves

Apex Waves Youtube Video

"The business transaction was super easy and friendly."


"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"


"They were very helpful to get me the test equipment that I need."


Delivery: UPS, FedEX and DHL – Free FedEx Ground on all orders
Overnight, Next Day Air or Expedited shipping options available
International delivery available
Same day shipping for in-stock on location
Warranty: All of our products are covered by our Apex Waves Warranty.
3 Year Warranty - New Surplus Parts
2 Year Warranty - Refurbished Parts
Returns: No hassle return policy.
Dedicated customer service team.
Payment: Authorize.Net paypal visa card master card american express card BB&T Bank better business bureau
Quick Quotes: Receive Price & Availability Today!
Calibration: Ask About Our Tiered Calibration Levels
Option & Modules: Confirm Your Requirements or Versions
Repair: Cost & Lead Time Available Upon Request for Service
Repair Evaluation: $150
Share this page: facebook twitter linkedIn