NI-9225, 3-Channel, Simultaneous Input, C Series Voltage Input Module
Need an Official Quote?
National Instruments NI-9225 C Series Voltage Input Module
The NI 9225 (Part Numbers: 780159-01 and 780159-02) 300 Vrms C Series Voltage Input Module was intended for the waveform estimations of high-voltage signals. The difference between the two NI 9225 part numbers is that part number 780159-02 is conformal coated, while part number 780159-01 is not. The 300 Vrms area empowers line-to-nonpartisan and additionally line-to-line estimations of 110 V control frameworks and line-to-impartial estimations of 240 V control networks. The three channels on the NI 9225 make the module perfectly suited for a three-stage framework. Voltage waveform estimations are fundamental for observing force quality occasions, such as hang, swell, transients, and harmonics. If the user chooses to put together the NI 9225 with the NI 9239 (10 V) and a current transducer, the outcome is an adjustable power quality checking or power metering framework.
NI C Series modules are intended to give high-exactness estimations to meet the requests of last generation DAQ and control applications. Every module contains estimation-particular signal molding to connect with a variety of sensors and signals, bank and channel-to-channel seclusion alternatives, and support for wide temperature extents to meet an assortment of use and natural needs in one durable module. Users can select from more than 100 C Series modules for estimation, control, and communication to interface applications to any sensor on any transport. The device is equipped with a screw terminal front connector.
The NI-9225 C Series Voltage Input Module comes with the following characteristics:
- 3 differential analog input channels, synchronous sources of info
- 50 kS/s per channel maximum sample rate, and a minimum sample rate of 1.613 kS/s
- Minimum and typical operating voltage ranges of 294 Vrms and 300 Vrms respectively
- Channel-to-channel disconnection
- Synchronize high-voltage estimations
- Program for USB with the simple to utilize NI-DAQmx driver software
- 24-bit analog input resolution
The NI device weighs 5.0 oz. It has a recommended operating temperature range of -40 to 70 °C, and a storage temperature range of -40 to 85 °C. The device has a power consumption of 495 mW maximum when in active mode, and 25 µW maximum in sleep mode.
Model | NI-9225 |
---|---|
Manufacturer | National Instruments |
Part Numbers | 780159-01, 780159-02 |
Type | C Series Voltage Input Module |
Differential Analog Input Channels | 3 |
Maximum Sample Rate | 50 kS/s per channel |
Analog Input Resolution | 24 bits |
Front Connector | Screw Terminal |
Weight | 5.0 oz. |
Warranty | Three Year Warranty |
NI-9225 Manual | User Manual and Maintenance Manual Available for Download |
Price | Contact a sales representative for a quote. |
Associated part numbers for the NI-9225:
197098A-01, 197098A-01L, 197098B-01L, 197098C-01L, 197098D-01L, 198862A-01L, 198862A-03L, 198862B-01L, 198862B-03L, 198862C-01L, 198862C-03L, 198862D-01L, 198862D-02L, 198862D-03L, 780159-01, 780159-02
National Instruments NI-9225 Frequently Asked Questions
Question: What is the difference between the two part numbers for the NI-9225?
Answer: The only difference between the two part numbers for the NI-9225 is that part number 780159-01 is not conformal coated, whereas part number 780159-02 is conformal coated.
Question: How long is the NI 9225 calibration interval?
Answer: The NI 9225 calibration interval is one year.
Question: When using the NI-9225 for high-vibration applications, how can I ensure safe operation?
Answer: The NI-9225 can be used with the NI 9971 backshell kit in high-vibration applications to ensure safe operation.
Question: What type of connector does the NI 9225 have?
Answer: The NI 9225 has three 2-terminal detachable screw-terminal connectors.
NI-9225 PDF Manuals
NI-9225 CALIBRATION PROCEDURE.PDF
NI-9225 LETTER OF VOLATILITY.PDF
NI-9225 OPERATING INSTRUCTIONS AND SPECIFICATIONS.PDF
Why Buy From Apex Waves:
"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"
"They were very helpful to get me the test equipment that I need."
NI-9225
Modular Systems > National Instruments > C Series
NI-9225, 3-Channel, Simultaneous Input, C Series Voltage Input Module
1-800-915-6216
- Description
- Technical Specifications
- FAQ
- Manuals & PDFs
National Instruments NI-9225 C Series Voltage Input Module
The NI 9225 (Part Numbers: 780159-01 and 780159-02) 300 Vrms C Series Voltage Input Module was intended for the waveform estimations of high-voltage signals. The difference between the two NI 9225 part numbers is that part number 780159-02 is conformal coated, while part number 780159-01 is not. The 300 Vrms area empowers line-to-nonpartisan and additionally line-to-line estimations of 110 V control frameworks and line-to-impartial estimations of 240 V control networks. The three channels on the NI 9225 make the module perfectly suited for a three-stage framework. Voltage waveform estimations are fundamental for observing force quality occasions, such as hang, swell, transients, and harmonics. If the user chooses to put together the NI 9225 with the NI 9239 (10 V) and a current transducer, the outcome is an adjustable power quality checking or power metering framework.
NI C Series modules are intended to give high-exactness estimations to meet the requests of last generation DAQ and control applications. Every module contains estimation-particular signal molding to connect with a variety of sensors and signals, bank and channel-to-channel seclusion alternatives, and support for wide temperature extents to meet an assortment of use and natural needs in one durable module. Users can select from more than 100 C Series modules for estimation, control, and communication to interface applications to any sensor on any transport. The device is equipped with a screw terminal front connector.
The NI-9225 C Series Voltage Input Module comes with the following characteristics:
- 3 differential analog input channels, synchronous sources of info
- 50 kS/s per channel maximum sample rate, and a minimum sample rate of 1.613 kS/s
- Minimum and typical operating voltage ranges of 294 Vrms and 300 Vrms respectively
- Channel-to-channel disconnection
- Synchronize high-voltage estimations
- Program for USB with the simple to utilize NI-DAQmx driver software
- 24-bit analog input resolution
The NI device weighs 5.0 oz. It has a recommended operating temperature range of -40 to 70 °C, and a storage temperature range of -40 to 85 °C. The device has a power consumption of 495 mW maximum when in active mode, and 25 µW maximum in sleep mode.
Model | NI-9225 |
---|---|
Manufacturer | National Instruments |
Part Numbers | 780159-01, 780159-02 |
Type | C Series Voltage Input Module |
Differential Analog Input Channels | 3 |
Maximum Sample Rate | 50 kS/s per channel |
Analog Input Resolution | 24 bits |
Front Connector | Screw Terminal |
Weight | 5.0 oz. |
Warranty | Three Year Warranty |
NI-9225 Manual | User Manual and Maintenance Manual Available for Download |
Price | Contact a sales representative for a quote. |
National Instruments NI-9225 Frequently Asked Questions
Question: What is the difference between the two part numbers for the NI-9225?
Answer: The only difference between the two part numbers for the NI-9225 is that part number 780159-01 is not conformal coated, whereas part number 780159-02 is conformal coated.
Question: How long is the NI 9225 calibration interval?
Answer: The NI 9225 calibration interval is one year.
Question: When using the NI-9225 for high-vibration applications, how can I ensure safe operation?
Answer: The NI-9225 can be used with the NI 9971 backshell kit in high-vibration applications to ensure safe operation.
Question: What type of connector does the NI 9225 have?
Answer: The NI 9225 has three 2-terminal detachable screw-terminal connectors.
NI-9225 PDF Manuals & Diagrams
NI-9225 PDF Manuals
NI-9225 CALIBRATION PROCEDURE.PDF
NI-9225 LETTER OF VOLATILITY.PDF
NI-9225 OPERATING INSTRUCTIONS AND SPECIFICATIONS.PDF
Why Buy From Apex Waves
"The business transaction was super easy and friendly."
"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"
"They were very helpful to get me the test equipment that I need."