Modular Systems > National Instruments > CompactRIO Controllers

National Instruments - CompactRIO Controllers - 781316-01National Instruments - CompactRIO Controllers - 781316-01 - Wiring781316-01 New781316-01 | Legacy, Refurbished and New Surplus
National Instruments - CompactRIO Controllers - 781316-01
National Instruments - CompactRIO Controllers - 781316-01 - Wiring
781316-01 New
781316-01 | Legacy, Refurbished and New Surplus
Same Day Calibration Available
2-3 Year Warranty Included
Free Ground Shipping

Or speak to a sales representative for additional information:


781316-01 Request for Availablility

781316-01, 14 Slots, 9 VDC to 30 VDC, NI-9157 CompactRIO Chassis
4.7/5 | 14 ratings
Fast Quote
Quoted Price

Need an Official Quote?

 

National Instruments 781316-01 CompactRIO Chassis

Part Number 781316-01 is the identifying part number for the National Instruments NI-9157 CompactRIO Chassis. The 781316-01 is a 14-slot chassis that ships with an integrated MXI-Express that has a maximum cable length of 7 m. Likewise, it comes with a Virtex-5 LX85 FPGA that has 51840 flip-flops and 51840 6-input LUTs. Similarly, it has 48 DSP48 slices and a block RAM of size 3456 kbits. Furthermore, it has timebases of frequencies 40, 80, 120, 160, or 200 MHz and the accuracy is ±100 ppm (maximum).

The screw terminal wiring on the 781316-01 supports copper wires of thickness ranging from 24 AWG to 14 AWG. Likewise, the recommended wire strip length is 6 mm while the temperature rating is 85 °C. Similarly, the torque for the screw terminals must be between 0.20 Nm to 0.25 Nm. Furthermore, screw flanges are provided for connector securement and the torque for screw flanges is between 0.3 Nm to 0.4 Nm. The 781316-01 supports input voltages from 9 VDC to 30 VDC and the maximum power input can be 55 W, 30 VDC. With no I/O modules, the chassis consumes a maximum power of 14.4 W while this can reach 30.7 W when 14 I/O modules are used. However, since these values are true for LabVIEW FPGA applications compiled at 80 MHz and can differ according to the user’s application. 
        
The 781316-01 is recommended for operation between temperatures of  0 °C to 55 °C at a relative humidity of 10% to 90%. Likewise, it is designed for indoor use only and should be operated within a maximum altitude of 2000 m. On the other hand, it can be stored between  -40 °C to  85°C at a relative humidity of 5% to 95%. The maximum voltage allowed between the V to C terminal in the 781316-01 is 30 VDC under Measurement Category I. The module is designed to meet the requirements of some of the following safety standards: EC 61010-1, EN 61010-1 UL 61010-1, CSA C22.2 No.61010-1, EN 60079-0, EN 60079-7, IEC 60079-0, IEC 60079-7, UL 60079-0, UL 60079-7, CSA C22.2 No. 60079-0, CSA C22.2 No. 60079-7.
 

Part Number781316-01
Model NameNI-9157
Part TypeCompactRIO Chassis
Number of Slots14
Bus ConnectorMXI
Maximum Cable Length7 m
FPGAVirtex-5 LX85
Input Voltage Range9 VDC to 30 VDC
Maximum Power Input55 W
Maximum Power Consumption14.4 W (with no I/O modules)
30.7 W (with 14 I/O modules)

  781316-01 PDF Manuals


Why Buy From Apex Waves:

Apex Waves Youtube Video

"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"


"They were very helpful to get me the test equipment that I need."



Delivery:    
UPS, FedEX and DHL – Free Ground on all orders
Overnight, Next Day Air or Expedited shipping options available
International delivery available
Same day shipping for in-stock on location
Warranty: All of our products are covered by our Apex Waves Warranty.
3 Year Warranty - New Surplus Parts
2 Year Warranty - Refurbished Parts
Returns: No hassle return policy.
Dedicated customer service team.
Payment: Authorize.net Visa Master Card American Express BB&T Better Business Bureau Dun & Bradstreet
Quick Quotes: Receive Price & Availability Today!
Calibration: Ask About Our Tiered Calibration Levels
Option & Modules: Confirm Your Requirements or Versions
Repair: Cost & Lead Time Available Upon Request for Service
Repair Evaluation: $150
Share this page: Facebook Icon Twitter Icon LinkedIn Icon
Common Typos: U81316-01, 7U1316-01, 7813W6-01, 781316-P1, 781316-0W

781316-01



Modular Systems > National Instruments > CompactRIO Controllers

781316-01, 14 Slots, 9 VDC to 30 VDC, NI-9157 CompactRIO Chassis
4.7/5 | 14 ratings

Call now for best pricing
1-800-915-6216

National Instruments 781316-01 CompactRIO Chassis

Part Number 781316-01 is the identifying part number for the National Instruments NI-9157 CompactRIO Chassis. The 781316-01 is a 14-slot chassis that ships with an integrated MXI-Express that has a maximum cable length of 7 m. Likewise, it comes with a Virtex-5 LX85 FPGA that has 51840 flip-flops and 51840 6-input LUTs. Similarly, it has 48 DSP48 slices and a block RAM of size 3456 kbits. Furthermore, it has timebases of frequencies 40, 80, 120, 160, or 200 MHz and the accuracy is ±100 ppm (maximum).

The screw terminal wiring on the 781316-01 supports copper wires of thickness ranging from 24 AWG to 14 AWG. Likewise, the recommended wire strip length is 6 mm while the temperature rating is 85 °C. Similarly, the torque for the screw terminals must be between 0.20 Nm to 0.25 Nm. Furthermore, screw flanges are provided for connector securement and the torque for screw flanges is between 0.3 Nm to 0.4 Nm. The 781316-01 supports input voltages from 9 VDC to 30 VDC and the maximum power input can be 55 W, 30 VDC. With no I/O modules, the chassis consumes a maximum power of 14.4 W while this can reach 30.7 W when 14 I/O modules are used. However, since these values are true for LabVIEW FPGA applications compiled at 80 MHz and can differ according to the user’s application. 
        
The 781316-01 is recommended for operation between temperatures of  0 °C to 55 °C at a relative humidity of 10% to 90%. Likewise, it is designed for indoor use only and should be operated within a maximum altitude of 2000 m. On the other hand, it can be stored between  -40 °C to  85°C at a relative humidity of 5% to 95%. The maximum voltage allowed between the V to C terminal in the 781316-01 is 30 VDC under Measurement Category I. The module is designed to meet the requirements of some of the following safety standards: EC 61010-1, EN 61010-1 UL 61010-1, CSA C22.2 No.61010-1, EN 60079-0, EN 60079-7, IEC 60079-0, IEC 60079-7, UL 60079-0, UL 60079-7, CSA C22.2 No. 60079-0, CSA C22.2 No. 60079-7.
 

Part Number781316-01
Model NameNI-9157
Part TypeCompactRIO Chassis
Number of Slots14
Bus ConnectorMXI
Maximum Cable Length7 m
FPGAVirtex-5 LX85
Input Voltage Range9 VDC to 30 VDC
Maximum Power Input55 W
Maximum Power Consumption14.4 W (with no I/O modules)
30.7 W (with 14 I/O modules)

781316-01 PDF Manuals & Diagrams

  781316-01 PDF Manuals


Why Buy From Apex Waves

Apex Waves Youtube Video

"The business transaction was super easy and friendly."


"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"


"They were very helpful to get me the test equipment that I need."


Delivery: UPS, FedEX and DHL – Free FedEx Ground on all orders
Overnight, Next Day Air or Expedited shipping options available
International delivery available
Same day shipping for in-stock on location
Warranty: All of our products are covered by our Apex Waves Warranty.
3 Year Warranty - New Surplus Parts
2 Year Warranty - Refurbished Parts
Returns: No hassle return policy.
Dedicated customer service team.
Payment: Authorize.Net paypal visa card master card american express card BB&T Bank better business bureau
Quick Quotes: Receive Price & Availability Today!
Calibration: Ask About Our Tiered Calibration Levels
Option & Modules: Confirm Your Requirements or Versions
Repair: Cost & Lead Time Available Upon Request for Service
Repair Evaluation: $150
Share this page: facebook twitter linkedIn