PXIe-4339, 8-Channel, 24-Bit, PXI Strain/Bridge Input Module
Need an Official Quote?
National Instruments PXIe-4339 PXI Strain/Bridge Input Module
The PXIe‑4339 (Part Number: 783531-01) is a universal Strain/Bridge Input Module by National Instruments, which is suitable for test cell installations that require both accuracy and flexibility. The NI PXIe-4339 Strain/Bridge Input Module is configurable through software. All channels can take bridge-based measurements and direct voltage measurements. This module has eight input ranges in ratio metric mode and four input ranges in voltage mode. The PXIe‑4339 also features per-channel wide bandwidth analog outputs, along with programmable excitation, TEDS support, and digital filtering. The NI PXIe-4339 can operate at a maximum sample rate of 25.6 kS/s.
The PXIe-4339 module uses two methods to correct the resistance errors. One is remote sensing and the other is shunt calibration. The NI PXIe 4339 has a built-in remote sensing system, which continuously and automatically corrects for errors in excitation leads. Remote Sensing is most appropriate for half- and full-bridge sensors. Besides, it is exclusively used in applications that have long wires and/or a small gauge. The resistance in the wires connects the excitation voltage to the bridge and causes a voltage drop. This voltage drop is called gain error. While using the remote sensing system, the PXIe-4339 can compensate for this gain error.
The NI PXIe-4339 Strain/Bridge Input Module has shunt calibration circuitry, which consists of a software-controlled switch. This switch is used in conjunction with the shunt calibration resistors. Shunt calibration can rectify errors from the resistance of the excitation wiring and correct errors from the wiring in the individual resistors of the bridge. There is sufficient resistance in the wiring to the sensor, so shunt calibration is best with three-wire quarter-bridge sensors.
Model | PXIe-4339 |
---|---|
Part Number | 783531-01 |
Manufacturer | National Instruments |
Type | PXI Strain/Bridge Input Module |
Differential Analog Input Channels | 8 |
Maximum Sample Rate | 25.6 kS/s |
Bridge Resistance | 1000 Ohm, 120 Ohm, 350 Ohm |
Dimensions | 6.3 x 3.9 in. |
Weight | 6.6 oz. |
Warranty | 2-3 Year Warranty |
PXIe-4339 Manual | User Manual and Maintenance Manual Available for Download |
Price | Contact a sales representative for a quote. |
Associated part numbers for the PXIe-4339:
154821A-01L, 154821B-01L, 154821C-01L, 154821D-01L, 157456A-01L, 783531-01
National Instruments PXIe-4339 Frequently Asked Questions
Question: What are the power requirements for the PXIe-4339?
Answer: The PXIe-4339 has power requirements of 1.5 A maximum at +12 V and 2.5 A maximum at +3.3 V.
Question: Which terminal block is meant for the NI PXIe-4339?
Answer: The NI PXIe-4339 can be used with the TB-4339 terminal block.
Question: What is the maximum current for the PXIe-4339?
Answer: The maximum current for the PXIe-4339 is 30 mA for each channel.
Question: How many DMA channels does the NI PXIe-4339 have?
Answer: The NI PXIe-4339 has 1 analog output DMA channel.
PXIe-4339 PDF Manuals
NI PXI 4220 CALIBRATION PROCEDURE.PDF
NI PXI 4220 USER MANUAL AND SPECIFICATIONS.PDF
NI PXIE 4339 AND TB 4339 B C INSTALLATION GUIDE AND TERMINAL BLOCK SPECIFICATIONS.PDF
NI PXIE 4330 4331 LETTER OF VOLATILITY.PDF
NI PXIE 4330 4331 SPECIFICATIONS.PDF
NI PXIE 4330 4331 USER MANUAL.PDF
NI PXIE 4339 CALIBRATION PROCEDURE.PDF
NI PXIE 4339 DEVICE SPECIFICATIONS.PDF
NI PXIE 4339 LETTER OF VOLATILITY.PDF
NI PXIE 4339 AND RM 4339 USER GUIDE AND TERMINAL BLOCK SPECIFICATIONS.PDF
NI SC EXPRESS 4330 4331 INSTALLATION GUIDE AND TERMINAL BLOCK SPECIFICATIONS.PDF
PXIE 4330 4331 CALIBRATION PROCEDURE.PDF
Driver Downloads for PXIe-4339
OS Compatibility:
Win XP 32-bit, Win 7 32-bit, Win 10 32-bit
Why Buy From Apex Waves:
"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"
"They were very helpful to get me the test equipment that I need."
PXIe-4339
Modular Systems > National Instruments > SC Express Series
PXIe-4339, 8-Channel, 24-Bit, PXI Strain/Bridge Input Module
1-800-915-6216
- Description
- Technical Specifications
- FAQ
- Manuals & PDFs
- Drivers
National Instruments PXIe-4339 PXI Strain/Bridge Input Module
The PXIe‑4339 (Part Number: 783531-01) is a universal Strain/Bridge Input Module by National Instruments, which is suitable for test cell installations that require both accuracy and flexibility. The NI PXIe-4339 Strain/Bridge Input Module is configurable through software. All channels can take bridge-based measurements and direct voltage measurements. This module has eight input ranges in ratio metric mode and four input ranges in voltage mode. The PXIe‑4339 also features per-channel wide bandwidth analog outputs, along with programmable excitation, TEDS support, and digital filtering. The NI PXIe-4339 can operate at a maximum sample rate of 25.6 kS/s.
The PXIe-4339 module uses two methods to correct the resistance errors. One is remote sensing and the other is shunt calibration. The NI PXIe 4339 has a built-in remote sensing system, which continuously and automatically corrects for errors in excitation leads. Remote Sensing is most appropriate for half- and full-bridge sensors. Besides, it is exclusively used in applications that have long wires and/or a small gauge. The resistance in the wires connects the excitation voltage to the bridge and causes a voltage drop. This voltage drop is called gain error. While using the remote sensing system, the PXIe-4339 can compensate for this gain error.
The NI PXIe-4339 Strain/Bridge Input Module has shunt calibration circuitry, which consists of a software-controlled switch. This switch is used in conjunction with the shunt calibration resistors. Shunt calibration can rectify errors from the resistance of the excitation wiring and correct errors from the wiring in the individual resistors of the bridge. There is sufficient resistance in the wiring to the sensor, so shunt calibration is best with three-wire quarter-bridge sensors.
Model | PXIe-4339 |
---|---|
Part Number | 783531-01 |
Manufacturer | National Instruments |
Type | PXI Strain/Bridge Input Module |
Differential Analog Input Channels | 8 |
Maximum Sample Rate | 25.6 kS/s |
Bridge Resistance | 1000 Ohm, 120 Ohm, 350 Ohm |
Dimensions | 6.3 x 3.9 in. |
Weight | 6.6 oz. |
Warranty | 2-3 Year Warranty |
PXIe-4339 Manual | User Manual and Maintenance Manual Available for Download |
Price | Contact a sales representative for a quote. |
National Instruments PXIe-4339 Frequently Asked Questions
Question: What are the power requirements for the PXIe-4339?
Answer: The PXIe-4339 has power requirements of 1.5 A maximum at +12 V and 2.5 A maximum at +3.3 V.
Question: Which terminal block is meant for the NI PXIe-4339?
Answer: The NI PXIe-4339 can be used with the TB-4339 terminal block.
Question: What is the maximum current for the PXIe-4339?
Answer: The maximum current for the PXIe-4339 is 30 mA for each channel.
Question: How many DMA channels does the NI PXIe-4339 have?
Answer: The NI PXIe-4339 has 1 analog output DMA channel.
PXIe-4339 PDF Manuals & Diagrams
PXIe-4339 PDF Manuals
NI PXI 4220 CALIBRATION PROCEDURE.PDF
NI PXI 4220 USER MANUAL AND SPECIFICATIONS.PDF
NI PXIE 4339 AND TB 4339 B C INSTALLATION GUIDE AND TERMINAL BLOCK SPECIFICATIONS.PDF
NI PXIE 4330 4331 LETTER OF VOLATILITY.PDF
NI PXIE 4330 4331 SPECIFICATIONS.PDF
NI PXIE 4330 4331 USER MANUAL.PDF
NI PXIE 4339 CALIBRATION PROCEDURE.PDF
NI PXIE 4339 DEVICE SPECIFICATIONS.PDF
NI PXIE 4339 LETTER OF VOLATILITY.PDF
NI PXIE 4339 AND RM 4339 USER GUIDE AND TERMINAL BLOCK SPECIFICATIONS.PDF
NI SC EXPRESS 4330 4331 INSTALLATION GUIDE AND TERMINAL BLOCK SPECIFICATIONS.PDF
PXIE 4330 4331 CALIBRATION PROCEDURE.PDF
Why Buy From Apex Waves
"The business transaction was super easy and friendly."
"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"
"They were very helpful to get me the test equipment that I need."