Description: | PCI-6033E, 64 Single Ended Analog Input, 100 kS/s, Multifunction DAQ |
(expedited shipping options available)
Need an Official Quote?
Or speak to a sales representative for additional information:
National Instruments PCI-6033E Multifunction DAQ
The NI PCI-6033E (Part number: 777516-01) Multifunction DAQ has 64 single-ended and 32 differential analog input channels, 500 kS per second maximum sample rate, eight digital I/O, two 24-bit counters/timers, and 0 analog output channels. This E Series Multifunction DAQ has DC input coupling and overvoltage protection. When overvoltage protection is powered on, the value is ±25 V. On the other hand, when overvoltage protection is powered off, the value is ±15 V. The PCI-6033E Multifunction DAQ has a 100-pin female 0.05 D-type I/O connector.
The user can program extremity and range settings on a by channel premise, so they can design each information channel. This model builds general adaptability by coordinating the input signal extents to those that the ADC can oblige. There are increases of 0.5, 1, 2, 5, 10, 20, 50, and 100 and are suited for a wide assortment of flag levels. With the best possible gain setting, users can utilize the full determination of the ADC to gauge the information signal. The input extremity and range selected relies upon the normal scope of the approaching signal. A huge information range can oblige an expansive signal variety yet lessens the voltage determination. Picking a smaller information range enhances the voltage determination; however, it may bring about the information signal leaving range. For the best outcomes, the user should coordinate the information range as nearly as conceivable to the normal scope of the information signal.
The PCI 6033E operates using the NI-DAQmx driver software which is compatible with software packages or application development environments (ADEs) such as LabVIEW, LabWindows/CVI, and Microsoft Visual Studio. The device hardware can be configured using the Measurement & Automation Explorer (MAX) tool.
The National Instruments PCI 6033E comes with a Dither feature that cannot be turned off. When the user utilizes dither, they include roughly 0.5 LSB rms of white Gaussian noise to the signal to be changed over by the ADC. This expansion is helpful for applications, including averaging to expand the determination of the PCI-6033 E Series board, as in alignment or examination. The device weighs 6.2 oz., and measures 6.9 x 4.2 in. in dimensions.
Associated Part Numbers: 184384-02, 184384A-02, 184384B-02, 184384C-02, 184384D-02, 184384E-02, 184384F-02, 184384G-02, 184384J-02, 184384K-02, 777516-01
Model | PCI-6033E |
---|---|
Manufacturer | National Instruments |
Part Number | 777516-01 |
Series | E Series |
Type | Multifunction DAQ |
Analog Input Channels | 64 single-ended or 32 differential |
Analog Input Resolution | 16 bits |
Dimensions | 6.9 in. × 4.2 in. |
Weight | 6.2 oz. |
Warranty | Three Year Warranty |
PCI-6033E Manual | User Manual and Maintenance Manual Available for Download |
Price | Contact a sales representative for a quote. |
National Instruments PCI-6033E Frequently Asked Questions
Question: Does the NI PCI-6033E have DIP switches, potentiometers, or jumpers?
Answer: No, the NI PCI-6033E does not have DIP switches, potentiometers, or jumpers, which makes it simple to calibrate and configure with software.
Question: Which types of cables can be used with the PCI-6033E?
Answer: The following cables can be used with the PCI-6033E: SH1006868, SH100100, and R1005050.
Question: Which type of ADC does the NI PCI-6033E have?
Answer: The NI PCI-6033E has a successive approximation ADC.
Question: What is the maximum working voltage of the PCI 6033E?
Answer: The maximum working voltage of the PCI 6033E is within ±11 V of ground.
PCI-6033E PDF Manuals
ARCHIVED E SERIES CALIBRATION PROCEDURE FOR TRADITIONAL NI DAQ 5BLEGACY5D .PDF
ARCHIVED LABVIEW DATA ACQUISITION BASICS MANUAL.PDF
ARCHIVED LABVIEW FUNCTION AND VI REFERENCE MANUAL.PDF
ARCHIVED MEASURE DATA ACQUISITION USER MANUAL.PDF
ARCHIVED NI DAQ FOR MAC OS RELEASE NOTES.PDF
ARCHIVED NI DAQ USER MANUAL FOR PC COMPATIBLES.PDF
ARCHIVED PCI E SERIES REGISTER LEVEL PROGRAMMER MANUAL.PDF
ARCHIVED TRADITIONAL NI DAQ USER MANUAL.PDF
BNC 2115 INSTALLATION GUIDE.PDF
DAQ GETTING STARTED GUIDE FOR PCI PCI EXPRESS.PDF
DAQ GETTING STARTED READ ME FIRST NI DAQMX AND DAQ DEVICE INSTALLATION GUIDE.PDF
DAQ MULTIFUNCTION I O MIO AND SIMULTANEOUS MULTIFUNCTION I O SMIO DEVICES CALIBRATION PROCEDURE.PDF
GUIDE D_INITIATION DAQ POUR PCI PCI EXPRESS.PDF
Why Buy From Apex Waves:
"The business transaction was super easy and friendly."
"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"
"They were very helpful to get me the test equipment that I need."
PCI-6033E
1-800-915-6216
- Description
- Technical Specifications
- FAQ
- Manuals & PDFs
National Instruments PCI-6033E Multifunction DAQ
The NI PCI-6033E (Part number: 777516-01) Multifunction DAQ has 64 single-ended and 32 differential analog input channels, 500 kS per second maximum sample rate, eight digital I/O, two 24-bit counters/timers, and 0 analog output channels. This E Series Multifunction DAQ has DC input coupling and overvoltage protection. When overvoltage protection is powered on, the value is ±25 V. On the other hand, when overvoltage protection is powered off, the value is ±15 V. The PCI-6033E Multifunction DAQ has a 100-pin female 0.05 D-type I/O connector.
The user can program extremity and range settings on a by channel premise, so they can design each information channel. This model builds general adaptability by coordinating the input signal extents to those that the ADC can oblige. There are increases of 0.5, 1, 2, 5, 10, 20, 50, and 100 and are suited for a wide assortment of flag levels. With the best possible gain setting, users can utilize the full determination of the ADC to gauge the information signal. The input extremity and range selected relies upon the normal scope of the approaching signal. A huge information range can oblige an expansive signal variety yet lessens the voltage determination. Picking a smaller information range enhances the voltage determination; however, it may bring about the information signal leaving range. For the best outcomes, the user should coordinate the information range as nearly as conceivable to the normal scope of the information signal.
The PCI 6033E operates using the NI-DAQmx driver software which is compatible with software packages or application development environments (ADEs) such as LabVIEW, LabWindows/CVI, and Microsoft Visual Studio. The device hardware can be configured using the Measurement & Automation Explorer (MAX) tool.
The National Instruments PCI 6033E comes with a Dither feature that cannot be turned off. When the user utilizes dither, they include roughly 0.5 LSB rms of white Gaussian noise to the signal to be changed over by the ADC. This expansion is helpful for applications, including averaging to expand the determination of the PCI-6033 E Series board, as in alignment or examination. The device weighs 6.2 oz., and measures 6.9 x 4.2 in. in dimensions.
Model | PCI-6033E |
---|---|
Manufacturer | National Instruments |
Part Number | 777516-01 |
Series | E Series |
Type | Multifunction DAQ |
Analog Input Channels | 64 single-ended or 32 differential |
Analog Input Resolution | 16 bits |
Dimensions | 6.9 in. × 4.2 in. |
Weight | 6.2 oz. |
Warranty | Three Year Warranty |
PCI-6033E Manual | User Manual and Maintenance Manual Available for Download |
Price | Contact a sales representative for a quote. |
National Instruments PCI-6033E Frequently Asked Questions
Question: Does the NI PCI-6033E have DIP switches, potentiometers, or jumpers?
Answer: No, the NI PCI-6033E does not have DIP switches, potentiometers, or jumpers, which makes it simple to calibrate and configure with software.
Question: Which types of cables can be used with the PCI-6033E?
Answer: The following cables can be used with the PCI-6033E: SH1006868, SH100100, and R1005050.
Question: Which type of ADC does the NI PCI-6033E have?
Answer: The NI PCI-6033E has a successive approximation ADC.
Question: What is the maximum working voltage of the PCI 6033E?
Answer: The maximum working voltage of the PCI 6033E is within ±11 V of ground.
PCI-6033E PDF Manuals & Diagrams
PCI-6033E PDF Manuals
ARCHIVED E SERIES CALIBRATION PROCEDURE FOR TRADITIONAL NI DAQ 5BLEGACY5D .PDF
ARCHIVED LABVIEW DATA ACQUISITION BASICS MANUAL.PDF
ARCHIVED LABVIEW FUNCTION AND VI REFERENCE MANUAL.PDF
ARCHIVED MEASURE DATA ACQUISITION USER MANUAL.PDF
ARCHIVED NI DAQ FOR MAC OS RELEASE NOTES.PDF
ARCHIVED NI DAQ USER MANUAL FOR PC COMPATIBLES.PDF
ARCHIVED PCI E SERIES REGISTER LEVEL PROGRAMMER MANUAL.PDF
ARCHIVED TRADITIONAL NI DAQ USER MANUAL.PDF
BNC 2115 INSTALLATION GUIDE.PDF
DAQ GETTING STARTED GUIDE FOR PCI PCI EXPRESS.PDF
DAQ GETTING STARTED READ ME FIRST NI DAQMX AND DAQ DEVICE INSTALLATION GUIDE.PDF
DAQ MULTIFUNCTION I O MIO AND SIMULTANEOUS MULTIFUNCTION I O SMIO DEVICES CALIBRATION PROCEDURE.PDF
GUIDE D_INITIATION DAQ POUR PCI PCI EXPRESS.PDF
Why Buy From Apex Waves
"The business transaction was super easy and friendly."
"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"
"They were very helpful to get me the test equipment that I need."