FP-DO-403 National Instruments Digital Output Module | Apex Waves | ImageFP-DO-403 National Instruments Digital Output Module | Apex Waves | ImageFP-DO-403 NewFP-DO-403 | Legacy, Refurbished and New Surplus
FP-DO-403 National Instruments Digital Output Module | Apex Waves | Image
FP-DO-403 National Instruments Digital Output Module | Apex Waves | Image
FP-DO-403 New
FP-DO-403 | Legacy, Refurbished and New Surplus

FP-DO-403

4.7/5 | 9 ratings

Modular Systems > National Instruments > FieldPoint

Part Number FP-DO-403
Manufacturer/Brand National Instruments
Description: FP-DO-403, 2 Isolated Channels, 0 to 32 VDC, Digital Output Module
Request for Availablility
Fast Quote
Quoted Price
Same Day Calibration Available
2-3 Year Warranty Included
Free Ground Shipping
  Get Pricing

Need an Official Quote?

 

Or speak to a sales representative for additional information:


National Instruments FP-DO-403 Digital Output Module

The NI FP-DO-403 (Part Number: 777518-403) module has 16 sinking digital output channels, On/Off LED indicators, is hot swappable, and mounts on an FP-TB-x FieldPoint Terminal Base. For applications where FieldPoint will perform implanted control on a machine, the line of items was intended to utilize standard 37-stick D-Sub connectors. On account of these normal and modest connectors, the client can fabricate custom links for establishments, lessening expenses of wiring and wiring mistakes. The NI device requires 600 mW of power from the network module. It has an output impedance and delay time of 0.12 Ω and 50 μs respectively, and a maximum OFF state leakage of 50 μA.

Utilizing the preparing point-to-point accessible in LabVIEW Real-Time, the user can perform handling and propelled control of signs. In this application, the program understands one point and passes each point inside capacities specials intended to perform constant capacities as midpoints, high/low counts, standard deviation, and frequency computations. With these projects, the user can undoubtedly set up continuous control cycles without the extra intricacy of gathering information buffers. When the user’s application requires powerful usefulness and quick advancement, the key is adaptable programming that coordinates consummately with the group. LabVIEW is a situation of standard realistic improvement in the business that gives all the fundamental devices to make propelled applications with complete estimation and control highlights.

The National Instruments FP-DO-403 Digital Output Module comes equipped with outputs that sink 2 A for each channel or 16 A squared per module. This Digital Output Module is compatible with voltages from 5 to 30 VDC, has 250 Vrms CAT II continuous channel-to-ground isolation, and is verified by 2,300 Vrms, 5 s dielectric withstand test.

The FP-DO-403 weighs 4.8 oz. It has recommended operating and storage temperature ranges of –40 to 70 °C and –45 to 85 °C respectively, a non-condensing relative humidity range of 10 to 90%, random and sinusoidal operating vibrations of 5 grms and 5 g respectively–all at a frequency range of 10 to 500 Hz. The module is designed to comply with the following electrical safety standards: IEC 61010-1, EN-61010-1, UL 61010-1, and CSA 61010-1.

ModelFP-DO-403
ManufacturerNational Instruments
Part Number777518-403
TypeDigital Output Module
Digital Output Channels16
Output TypeSinking
Voltage Range5 to 30 VDC
Power from Network Module600 mW
Weight4.8 oz.
WarrantyThree Year Warranty
FP-DO-403 ManualUser Manual and Maintenance Manual Available for Download
PriceContact a sales representative for a quote.

Associated part numbers for the FP-DO-403:

186085A-01, 777518-403

National Instruments FP-DO-403 Frequently Asked Questions

 

Question: What is the output delay time for the FP-DO-403?

 

Answer: The output delay time for the FP-DO-403 is 50 µs.

 

Question: What is the output current rating for the NI FP-DO-403 module?

 

Answer: The output current rating for the NI FP-DO-403 module is 2 A.

 

Question: Does the FP-DO-403 have electronically fused outputs?

 

Answer: No, the FP-DO-403 does not have electronically fused outputs.

 

Question: What is the maximum OFF state leakage for the NI FP-DO-403?

 

Answer: The maximum OFF state leakage for the NI FP-DO-403 is 50 µA.

  FP-DO-403 PDF Manuals


Why Buy From Apex Waves:

Apex Waves Youtube Video

"The business transaction was super easy and friendly."


"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"


"They were very helpful to get me the test equipment that I need."



Delivery:    
UPS, FedEX and DHL – Free Ground on all orders
Overnight, Next Day Air or Expedited shipping options available
International delivery available
Same day shipping for in-stock on location
Warranty: All of our products are covered by our Apex Waves Warranty.
3 Year Warranty - New Surplus Parts
2 Year Warranty - Refurbished Parts
Returns: No hassle return policy.
Dedicated customer service team.
Payment: Authorize.net Visa Master Card American Express BB&T Better Business Bureau Dun & Bradstreet
Quick Quotes: Receive Price & Availability Today!
Calibration: Ask About Our Tiered Calibration Levels
Option & Modules: Confirm Your Requirements or Versions
Repair: Cost & Lead Time Available Upon Request for Service
Repair Evaluation: $150
Share this page: Facebook Icon Twitter Icon LinkedIn Icon
Common Typos: GP-DO-403, VP-DO-403, FL-DO-403, FP-DO-T03, FP-DO-4P3

FP-DO-403



Modular Systems > National Instruments > FieldPoint

FP-DO-403
4.7/5 | 9 ratings

FP-DO-403, 2 Isolated Channels, 0 to 32 VDC, Digital Output Module

Request for Availablility
Same Day Calibration Available
2-3 Year Warranty Included
Free Ground Shipping
  Get Pricing

Call now for best pricing
1-800-915-6216

National Instruments FP-DO-403 Digital Output Module

The NI FP-DO-403 (Part Number: 777518-403) module has 16 sinking digital output channels, On/Off LED indicators, is hot swappable, and mounts on an FP-TB-x FieldPoint Terminal Base. For applications where FieldPoint will perform implanted control on a machine, the line of items was intended to utilize standard 37-stick D-Sub connectors. On account of these normal and modest connectors, the client can fabricate custom links for establishments, lessening expenses of wiring and wiring mistakes. The NI device requires 600 mW of power from the network module. It has an output impedance and delay time of 0.12 Ω and 50 μs respectively, and a maximum OFF state leakage of 50 μA.

Utilizing the preparing point-to-point accessible in LabVIEW Real-Time, the user can perform handling and propelled control of signs. In this application, the program understands one point and passes each point inside capacities specials intended to perform constant capacities as midpoints, high/low counts, standard deviation, and frequency computations. With these projects, the user can undoubtedly set up continuous control cycles without the extra intricacy of gathering information buffers. When the user’s application requires powerful usefulness and quick advancement, the key is adaptable programming that coordinates consummately with the group. LabVIEW is a situation of standard realistic improvement in the business that gives all the fundamental devices to make propelled applications with complete estimation and control highlights.

The National Instruments FP-DO-403 Digital Output Module comes equipped with outputs that sink 2 A for each channel or 16 A squared per module. This Digital Output Module is compatible with voltages from 5 to 30 VDC, has 250 Vrms CAT II continuous channel-to-ground isolation, and is verified by 2,300 Vrms, 5 s dielectric withstand test.

The FP-DO-403 weighs 4.8 oz. It has recommended operating and storage temperature ranges of –40 to 70 °C and –45 to 85 °C respectively, a non-condensing relative humidity range of 10 to 90%, random and sinusoidal operating vibrations of 5 grms and 5 g respectively–all at a frequency range of 10 to 500 Hz. The module is designed to comply with the following electrical safety standards: IEC 61010-1, EN-61010-1, UL 61010-1, and CSA 61010-1.

ModelFP-DO-403
ManufacturerNational Instruments
Part Number777518-403
TypeDigital Output Module
Digital Output Channels16
Output TypeSinking
Voltage Range5 to 30 VDC
Power from Network Module600 mW
Weight4.8 oz.
WarrantyThree Year Warranty
FP-DO-403 ManualUser Manual and Maintenance Manual Available for Download
PriceContact a sales representative for a quote.

National Instruments FP-DO-403 Frequently Asked Questions

 

Question: What is the output delay time for the FP-DO-403?

 

Answer: The output delay time for the FP-DO-403 is 50 µs.

 

Question: What is the output current rating for the NI FP-DO-403 module?

 

Answer: The output current rating for the NI FP-DO-403 module is 2 A.

 

Question: Does the FP-DO-403 have electronically fused outputs?

 

Answer: No, the FP-DO-403 does not have electronically fused outputs.

 

Question: What is the maximum OFF state leakage for the NI FP-DO-403?

 

Answer: The maximum OFF state leakage for the NI FP-DO-403 is 50 µA.

Why Buy From Apex Waves

Apex Waves Youtube Video

"The business transaction was super easy and friendly."


"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"


"They were very helpful to get me the test equipment that I need."


Delivery: UPS, FedEX and DHL – Free FedEx Ground on all orders
Overnight, Next Day Air or Expedited shipping options available
International delivery available
Same day shipping for in-stock on location
Warranty: All of our products are covered by our Apex Waves Warranty.
3 Year Warranty - New Surplus Parts
2 Year Warranty - Refurbished Parts
Returns: No hassle return policy.
Dedicated customer service team.
Payment: Authorize.Net paypal visa card master card american express card BB&T Bank better business bureau
Quick Quotes: Receive Price & Availability Today!
Calibration: Ask About Our Tiered Calibration Levels
Option & Modules: Confirm Your Requirements or Versions
Repair: Cost & Lead Time Available Upon Request for Service
Repair Evaluation: $150