Description: | USB-6366, 8 AI, 2 AO, 24 DIO, USB Multifunction I/O Device |
Need an Official Quote?
Or speak to a sales representative for additional information:
National Instruments USB-6366 Multifunction I/O Device
The NI USB-6366 (Part Numbers: 781445-01, 782264-01, 781445-02, 782263-01, 782262-01) is a device from National Instruments. This Multifunction I/O Device has 8 differential analog input channels and does not have any single-ended input channels. The amount of working voltage for all inputs is the same. The size of this input is ±11 V for all ranges. This input voltage is the same size for the positive input and the negative input. There are additionally two analog output channels, 24 bidirectional digital channels, 4 counters/timers, and either 32 MS or 64 MS analog input FIFO buffer size. The DAQ USB-6366 is equipped with a single frequency generator. This generator utilizes a different number of divisors. The range of divisors is 1-16. The frequency generator can generate different frequencies. The greatest amount of frequency is 20 MHz. The smallest amount of frequency is 100 kHz.
The USB 6366 NI warms up in a short time of 15 minutes. For best performance, this device needs calibration every 2 years. This Multifunction I/O Device offers a working voltage of 11 V. This is the greatest value for the working voltage. This voltage is valid for Category I of the measurements. This working voltage includes common mode also.
The NI USB-6366 X Series DAQ Device offers a wide range of operating humidity. The size of this range is 10% to 90%. The storage humidity range is from 5% to 95% for this module. Both the humidity ranges also include noncondensing conditions. This device is best for indoor operating.
Associated Part Numbers: 150159F-01L, 152804B-01L, 781445-01, 781445-02, 782262-01, 782263-01, 782264-01, 786508-01
Model | USB-6366 |
---|---|
Manufacturer | National Instruments |
Part Numbers | 781445-01, 782264-01, 781445-02, 782263-01, 782262-01 |
Type | Multifunction I/O Device |
Analog Input Channels | 8 differential |
Analog Output Channels | 2 |
Maximum Sample Rate | 2 MS/s per channel |
Dimensions | Mass Termination: 7.3 × 6.8 × 1.4 in.; Screw Terminal: 10.4 × 6.8 × 1.4 in.; BNC: 8.0 × 7.3 × 2.7 in. |
Weight | Mass Termination: 2 lb 2.1 oz.; Screw Terminal: 3 lb 2.3 oz; BNC: 3 lb 6.2 oz. |
Warranty | Three Year Warranty |
USB-6366 Manual | User Manual and Maintenance Manual Available for Download |
Price | Contact a sales representative for a quote. |
National Instruments USB-6366 Frequently Asked Questions
Question: What are the differences between the part numbers for the NI USB-6366?
Answer: The NI USB-6366 has three front connector types available, as well as two analog input FIFO buffer sizes. First, part number 781445-01 has screw terminal front connectors and 32 MS analog input FIFO buffer size. Part number 782264-01 has VHDCI front connectors and 64 MS analog input FIFO buffer size. Next, part number 781445-02 has screw terminal front connectors and 64 MS analog input FIFO buffer size. Lastly, part number 782263-01 has BNC front connectors and 64 MS analog input FIFO buffer size.Part number 782262-01 refers to the board only kit version of the USB-6366.
Question: What is the maximum update rate for the DAQ USB-6366?
Answer: The maximum update rate for the DAQ USB-6366 is 3.33 MS/s per channel.
Question: Is it possible to sample multiple channels on the USB 6366 NI with different sample rates?
Answer: No, the USB 6366 NI does not allow for channels to have different sample rates because they all share one sample clock.
Question: Which position measurements can the counters/timers on the NI USB-6366 X Series DAQ perform?
Answer: The counters/timers on the NI USB-6366 X Series DAQ can perform the following position measurements: two-edge separation, semi-period, edge counting, pulse width, period, and pulse.
USB-6366 PDF Manuals
DAQ GETTING STARTED GUIDE FOR EXTERNALLY POWERED USB.PDF
DAQ GETTING STARTED GUIDE FOR PCI PCI EXPRESS.PDF
DAQ GETTING STARTED READ ME FIRST NI DAQMX AND DAQ DEVICE INSTALLATION GUIDE.PDF
FERRITE INSTALLATION NOTE TO USERS.PDF
LOCKING LID FOR USB SCREW TERMINAL DEVICES USER GUIDE.PDF
NI 62XX 63XX PINOUT LABELS FOR THE SCB 68 NOTE TO USERS.PDF
NI 62XX 63XX PINOUT LABELS FOR THE SCB 68A NOTE TO USERS.PDF
NI 6366 DEVICE SPECIFICATIONS.PDF
USB 634X 635X 636X OEM USER GUIDE.PDF
USB 6356 66 LETTER OF VOLATILITY.PDF
Why Buy From Apex Waves:
"The business transaction was super easy and friendly."
"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"
"They were very helpful to get me the test equipment that I need."
USB-6366
1-800-915-6216
- Description
- Technical Specifications
- FAQ
- Manuals & PDFs
National Instruments USB-6366 Multifunction I/O Device
The NI USB-6366 (Part Numbers: 781445-01, 782264-01, 781445-02, 782263-01, 782262-01) is a device from National Instruments. This Multifunction I/O Device has 8 differential analog input channels and does not have any single-ended input channels. The amount of working voltage for all inputs is the same. The size of this input is ±11 V for all ranges. This input voltage is the same size for the positive input and the negative input. There are additionally two analog output channels, 24 bidirectional digital channels, 4 counters/timers, and either 32 MS or 64 MS analog input FIFO buffer size. The DAQ USB-6366 is equipped with a single frequency generator. This generator utilizes a different number of divisors. The range of divisors is 1-16. The frequency generator can generate different frequencies. The greatest amount of frequency is 20 MHz. The smallest amount of frequency is 100 kHz.
The USB 6366 NI warms up in a short time of 15 minutes. For best performance, this device needs calibration every 2 years. This Multifunction I/O Device offers a working voltage of 11 V. This is the greatest value for the working voltage. This voltage is valid for Category I of the measurements. This working voltage includes common mode also.
The NI USB-6366 X Series DAQ Device offers a wide range of operating humidity. The size of this range is 10% to 90%. The storage humidity range is from 5% to 95% for this module. Both the humidity ranges also include noncondensing conditions. This device is best for indoor operating.
Model | USB-6366 |
---|---|
Manufacturer | National Instruments |
Part Numbers | 781445-01, 782264-01, 781445-02, 782263-01, 782262-01 |
Type | Multifunction I/O Device |
Analog Input Channels | 8 differential |
Analog Output Channels | 2 |
Maximum Sample Rate | 2 MS/s per channel |
Dimensions | Mass Termination: 7.3 × 6.8 × 1.4 in.; Screw Terminal: 10.4 × 6.8 × 1.4 in.; BNC: 8.0 × 7.3 × 2.7 in. |
Weight | Mass Termination: 2 lb 2.1 oz.; Screw Terminal: 3 lb 2.3 oz; BNC: 3 lb 6.2 oz. |
Warranty | Three Year Warranty |
USB-6366 Manual | User Manual and Maintenance Manual Available for Download |
Price | Contact a sales representative for a quote. |
National Instruments USB-6366 Frequently Asked Questions
Question: What are the differences between the part numbers for the NI USB-6366?
Answer: The NI USB-6366 has three front connector types available, as well as two analog input FIFO buffer sizes. First, part number 781445-01 has screw terminal front connectors and 32 MS analog input FIFO buffer size. Part number 782264-01 has VHDCI front connectors and 64 MS analog input FIFO buffer size. Next, part number 781445-02 has screw terminal front connectors and 64 MS analog input FIFO buffer size. Lastly, part number 782263-01 has BNC front connectors and 64 MS analog input FIFO buffer size.Part number 782262-01 refers to the board only kit version of the USB-6366.
Question: What is the maximum update rate for the DAQ USB-6366?
Answer: The maximum update rate for the DAQ USB-6366 is 3.33 MS/s per channel.
Question: Is it possible to sample multiple channels on the USB 6366 NI with different sample rates?
Answer: No, the USB 6366 NI does not allow for channels to have different sample rates because they all share one sample clock.
Question: Which position measurements can the counters/timers on the NI USB-6366 X Series DAQ perform?
Answer: The counters/timers on the NI USB-6366 X Series DAQ can perform the following position measurements: two-edge separation, semi-period, edge counting, pulse width, period, and pulse.
USB-6366 PDF Manuals & Diagrams
USB-6366 PDF Manuals
DAQ GETTING STARTED GUIDE FOR EXTERNALLY POWERED USB.PDF
DAQ GETTING STARTED GUIDE FOR PCI PCI EXPRESS.PDF
DAQ GETTING STARTED READ ME FIRST NI DAQMX AND DAQ DEVICE INSTALLATION GUIDE.PDF
FERRITE INSTALLATION NOTE TO USERS.PDF
LOCKING LID FOR USB SCREW TERMINAL DEVICES USER GUIDE.PDF
NI 62XX 63XX PINOUT LABELS FOR THE SCB 68 NOTE TO USERS.PDF
NI 62XX 63XX PINOUT LABELS FOR THE SCB 68A NOTE TO USERS.PDF
NI 6366 DEVICE SPECIFICATIONS.PDF
USB 634X 635X 636X OEM USER GUIDE.PDF
USB 6356 66 LETTER OF VOLATILITY.PDF
Why Buy From Apex Waves
"The business transaction was super easy and friendly."
"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"
"They were very helpful to get me the test equipment that I need."