PCI-CAN/LS National Instruments CAN Interface Device | Apex Waves | ImagePCI-CAN/LS National Instruments CAN Interface Device | Apex Waves | ImagePCI-CAN-LS NewPCI-CAN-LS | Legacy, Refurbished and New Surplus
PCI-CAN/LS National Instruments CAN Interface Device | Apex Waves | Image
PCI-CAN/LS National Instruments CAN Interface Device | Apex Waves | Image
PCI-CAN-LS New
PCI-CAN-LS | Legacy, Refurbished and New Surplus

PCI-CAN-LS

4.8/5 | 5 ratings

Modular Systems > National Instruments > PCI CAN Interfaces

Part Number PCI-CAN-LS
Manufacturer/Brand National Instruments
Description: PCI-CAN/LS, 1-Port, CAN Interface Device
Request for Availablility
Fast Quote
Quoted Price
Same Day Calibration Available
2-3 Year Warranty Included
Free Ground Shipping
  Get Pricing

Need an Official Quote?

 

Or speak to a sales representative for additional information:


National Instruments PCI-CAN/LS CAN interface Device

The PCI-CAN/LS is a low-speed CAN Interface Device by National Instruments. The part number of the device is 778007-01. The CAN Interface Device is a fault-tolerant CAN device used to program CAN applications. This model is designed to communicate with CAN devices with a low speed. The PCI-CAN/LS offers advanced functions like listen-only and self-reception filter modes. The PCI-CAN/LS interface device is equipped with special transceivers. This feature supports sleep/wake-up mode. This device is also compatible with the RTSI bus. The PCI-CAN/LS can be synchronized with DAQ, CAN, and motion devices for PCI. The RTSI bus also enables the PCI-CAN/LS to share signals.

The PCI-CAN/LS CAN Interface Device is a single port device. To interface with other devices, the PCI-CAN/LS is equipped with a 9-pin D-SUB connector. The DB-9 connector used in the PCI-CAN/LS is a male connector. A Philips SJA1000 CAN controller is also available in the device. This connector is used to implement CAN protocols. The PCI-CAN/LS is also compatible with 11-bit and 29-bit arbitration IDs. An Intel microprocessor is used in the PCI-CAN/LS device for timed CAN frame transfer. This model can sample data at a maximum rate of 125 kb/sec and supports 100% busload. The PCI-CAN/LS also incorporates a TJA1054A transceiver.  

The PCI-CAN/LS supports two operating systems. These systems are Windows and LabVIEW Real-Time. The supported versions of Windows are Windows 2000, NT, XP, Me, and 98. The PCI-CAN/LS CAN Interface dDevice comes with built-in Application and Driver software. The supported application software is the bus monitor utility. The built-in driver software is NI-CAN. The device with built-in NI-CAN is used in several industrial and research applications. NI-CAN is specifically ideal for automation applications.  

ModelPCI-CAN/LS
ManufacturerNational Instruments
Part Number778007-01
TypeCAN Interface Device
MicroprocessorIntel 80386EX
Ports1
TransceiverTJA1054A
Interface typeISO 11898
Maximum Baud Rate125 Kb/sec
I/O Connector9-pin male D-SUB
CAN_H, CAN_L Bus Lines–10 to +27 VDC
IsolationOptical Isolation up to 500 V
Power Requirements+ 5 VDC -- 800 mA
Dimensions8.15 in.by 6.9 in.
Software DriverNI-CAN
Warranty2-3 Year Warranty
PCI-CAN/LS ManualUser Manual and Maintenance Manual Available for Download
PriceContact a sales representative for a quote.

National Instruments PCI-CAN/LS Frequently Asked Questions

 

Question: What is the supported NI PCI-CAN/LS driver software?

 

Answer: The supported NI PCI-CAN/LS driver software is NI-CAN.

 

Question: What does the LS in PCI-CAN/LS indicate?

 

Answer: LS indicates the PCI-CAN/LS is a low-speed CAN device.

 

Question: Does the NI PCI-CAN/LS meet the requirements for all automotive networks?

 

Answer: Yes, all National Instruments CAN interfaces meet physical requirements, as well as electrical requirements for automotive networks based on CAN.

 

Question: I’m getting an error message on the PCI-CAN/LS. What should I do if this continues?

 

Answer: Make sure you have the latest NI-CAN driver installed on the PCI-CAN/LS.

 

Question: Can I use a NI PCI-CAN/LS card with a high-speed device?

 

Answer: The NI PCI-CAN/LS, is a low-speed card, but it can be used on high speed devices. Check that the cables and the high-speed device itself are not internally terminated. You can do this by measuring the resistance between CAN_H and CAN_L with the cable connected and without the cable connected and comparing.


Why Buy From Apex Waves:

Apex Waves Youtube Video

"The business transaction was super easy and friendly."


"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"


"They were very helpful to get me the test equipment that I need."



Delivery:    
UPS, FedEX and DHL – Free Ground on all orders
Overnight, Next Day Air or Expedited shipping options available
International delivery available
Same day shipping for in-stock on location
Warranty: All of our products are covered by our Apex Waves Warranty.
3 Year Warranty - New Surplus Parts
2 Year Warranty - Refurbished Parts
Returns: No hassle return policy.
Dedicated customer service team.
Payment: Authorize.net Visa Master Card American Express BB&T Better Business Bureau Dun & Bradstreet
Quick Quotes: Receive Price & Availability Today!
Calibration: Ask About Our Tiered Calibration Levels
Option & Modules: Confirm Your Requirements or Versions
Repair: Cost & Lead Time Available Upon Request for Service
Repair Evaluation: $150
Share this page: Facebook Icon Twitter Icon LinkedIn Icon
Common Typos: PCI-DAN-LS, PCI-FAN-LS, PCI-CZN-LS, PCI-CAN-LW, PCI-CAN-LE

PCI-CAN-LS



Modular Systems > National Instruments > PCI CAN Interfaces

PCI-CAN-LS
4.8/5 | 5 ratings

PCI-CAN/LS, 1-Port, CAN Interface Device

Request for Availablility
Same Day Calibration Available
2-3 Year Warranty Included
Free Ground Shipping
  Get Pricing

Call now for best pricing
1-800-915-6216

National Instruments PCI-CAN/LS CAN interface Device

The PCI-CAN/LS is a low-speed CAN Interface Device by National Instruments. The part number of the device is 778007-01. The CAN Interface Device is a fault-tolerant CAN device used to program CAN applications. This model is designed to communicate with CAN devices with a low speed. The PCI-CAN/LS offers advanced functions like listen-only and self-reception filter modes. The PCI-CAN/LS interface device is equipped with special transceivers. This feature supports sleep/wake-up mode. This device is also compatible with the RTSI bus. The PCI-CAN/LS can be synchronized with DAQ, CAN, and motion devices for PCI. The RTSI bus also enables the PCI-CAN/LS to share signals.

The PCI-CAN/LS CAN Interface Device is a single port device. To interface with other devices, the PCI-CAN/LS is equipped with a 9-pin D-SUB connector. The DB-9 connector used in the PCI-CAN/LS is a male connector. A Philips SJA1000 CAN controller is also available in the device. This connector is used to implement CAN protocols. The PCI-CAN/LS is also compatible with 11-bit and 29-bit arbitration IDs. An Intel microprocessor is used in the PCI-CAN/LS device for timed CAN frame transfer. This model can sample data at a maximum rate of 125 kb/sec and supports 100% busload. The PCI-CAN/LS also incorporates a TJA1054A transceiver.  

The PCI-CAN/LS supports two operating systems. These systems are Windows and LabVIEW Real-Time. The supported versions of Windows are Windows 2000, NT, XP, Me, and 98. The PCI-CAN/LS CAN Interface dDevice comes with built-in Application and Driver software. The supported application software is the bus monitor utility. The built-in driver software is NI-CAN. The device with built-in NI-CAN is used in several industrial and research applications. NI-CAN is specifically ideal for automation applications.  

ModelPCI-CAN/LS
ManufacturerNational Instruments
Part Number778007-01
TypeCAN Interface Device
MicroprocessorIntel 80386EX
Ports1
TransceiverTJA1054A
Interface typeISO 11898
Maximum Baud Rate125 Kb/sec
I/O Connector9-pin male D-SUB
CAN_H, CAN_L Bus Lines–10 to +27 VDC
IsolationOptical Isolation up to 500 V
Power Requirements+ 5 VDC -- 800 mA
Dimensions8.15 in.by 6.9 in.
Software DriverNI-CAN
Warranty2-3 Year Warranty
PCI-CAN/LS ManualUser Manual and Maintenance Manual Available for Download
PriceContact a sales representative for a quote.

National Instruments PCI-CAN/LS Frequently Asked Questions

 

Question: What is the supported NI PCI-CAN/LS driver software?

 

Answer: The supported NI PCI-CAN/LS driver software is NI-CAN.

 

Question: What does the LS in PCI-CAN/LS indicate?

 

Answer: LS indicates the PCI-CAN/LS is a low-speed CAN device.

 

Question: Does the NI PCI-CAN/LS meet the requirements for all automotive networks?

 

Answer: Yes, all National Instruments CAN interfaces meet physical requirements, as well as electrical requirements for automotive networks based on CAN.

 

Question: I’m getting an error message on the PCI-CAN/LS. What should I do if this continues?

 

Answer: Make sure you have the latest NI-CAN driver installed on the PCI-CAN/LS.

 

Question: Can I use a NI PCI-CAN/LS card with a high-speed device?

 

Answer: The NI PCI-CAN/LS, is a low-speed card, but it can be used on high speed devices. Check that the cables and the high-speed device itself are not internally terminated. You can do this by measuring the resistance between CAN_H and CAN_L with the cable connected and without the cable connected and comparing.

Why Buy From Apex Waves

Apex Waves Youtube Video

"The business transaction was super easy and friendly."


"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"


"They were very helpful to get me the test equipment that I need."


Delivery: UPS, FedEX and DHL – Free FedEx Ground on all orders
Overnight, Next Day Air or Expedited shipping options available
International delivery available
Same day shipping for in-stock on location
Warranty: All of our products are covered by our Apex Waves Warranty.
3 Year Warranty - New Surplus Parts
2 Year Warranty - Refurbished Parts
Returns: No hassle return policy.
Dedicated customer service team.
Payment: Authorize.Net paypal visa card master card american express card BB&T Bank better business bureau
Quick Quotes: Receive Price & Availability Today!
Calibration: Ask About Our Tiered Calibration Levels
Option & Modules: Confirm Your Requirements or Versions
Repair: Cost & Lead Time Available Upon Request for Service
Repair Evaluation: $150
Share this page: facebook twitter linkedIn