PXI-4072 National Instruments Digital Multimeter | Apex Waves | ImagePXI-4072 National Instruments Digital Multimeter | Apex Waves | ImagePXI-4072 NewPXI-4072 | Legacy, Refurbished and New Surplus
PXI-4072 National Instruments Digital Multimeter | Apex Waves | Image
PXI-4072 National Instruments Digital Multimeter | Apex Waves | Image
PXI-4072 New
PXI-4072 | Legacy, Refurbished and New Surplus

PXI-4072

4.9/5 | 10 ratings

Meters > National Instruments > NI-407x Series

Part Number PXI-4072
Manufacturer/Brand National Instruments
Description: PXI-4072, 6.5 Digit, ±300 V, PXI Digital Multimeter
In Stock | Ships Today
Fast Quote
Quoted Price
Same Day Calibration Available
2-3 Year Warranty Included
Free Ground Shipping
  Get Pricing

Need an Official Quote?

 

Or speak to a sales representative for additional information:


National Instruments PXI-4072 PXI Digital Multimeter

The National Instruments PXI-4072 (Part Number: 778270-01) FlexDMM gives the user the usefulness of three normal instruments in a solitary slot 3U PXI module: a 6½-digit multimeter, an LCR meter, and disengaged digitizer which has a maximum sample rate of 1.8 MS per second. The NI PXI-4072 FlexDMM brings computerized multimeters closer to providing universal estimation ability by offering the user the 20 most basic ATE estimations, including voltage, current, capacitance, inductance, temperature, and resistance. By coordinating these estimations into one PXI module, the user can diminish test framework size and cost, increment throughput, and abbreviate test development time. This model can likewise be utilized with PXI switches to frame a multichannel information obtaining framework.

These National Instruments PC-based advanced multimeters and LCR meters are upgraded for computerized test. Accessible on buses from USB to PXI, these DMMs consolidate offer more than 150 NI switch topology alternatives to make high-channel-count test frameworks. The device has a DC voltage range of -300 V to 300 V; and a DC current range of -1 A to 1 A. It is equipped with a 6.5 digit resolution. The PXI-4072 has a DC range/function change of 100/s, and an AC range/function change of 10/s. Additionally, the device has an operating ambient temperature range of 0 °C to 55 °C.

The device operates on the NI-DMM driver software. National Instruments NI PXI-4072 FlexDMM and LCR Meter drivers are minor programs that empower the Digital Multimeter to communicate with the working framework software. Keeping the NI PXI-4072 FlexDMM and LCR Meter software updated prevents crashes and amplifies equipment and framework execution. Utilizing obsolete or degenerate National Instruments PXI-4072 FlexDMM and LCR Meter drivers can cause framework blunders, crashes, and make your PC or equipment fail. Besides, introducing the wrong National Instruments drivers can aggravate these issues even more. Also, your computer should have one of the following configurations: a PCI slot, a x1, x4, x8, x16 PCI Express slot, a USB 2.0 or 1.1 slot, a PXI, PXI/CompactPCI, or PXI/SCXI combination chassis, chassis documentation, and a controller. Additional specifications for the PXI-4072 can be found in the user manuals and datasheets under the "Manuals & PDFs" tab.

PXI-4072 Maintenance Status has been announced by National Instruments, but the multimeter will still be available for purchase and repairs by Apex Waves.

ModelPXI-4072
ManufacturerNational Instruments
Part Number778270-01
HTS Code8471804000
TypePXI Digital Multimeter
Maximum Sample Rate1.8 MS/s
DC Voltage Range-300 V to 300 V
DC Current Range-1 A to 1 A
Digits of Resoution6.5
WarrantyThree Year Warranty
PXI-4072 ManualUser Manual and Maintenance Manual Available for Download
PriceContact a sales representative for a quote.

Associated part numbers for the PXI-4072:

1902.22, 190222C-01, 190222D-02, 190222F-02, 190222F-02L, 190222G-02L, 190222H-02L, 190222J-02L, 191.485, 191485A-03, 191485B-03, 191485C-03, 191485D-03, 191485F-03, 191485G-03L, 191485H-03L, 191485J-03L, 191485K-03L, 191485L-03L, 191485M-03L, 778270-01

National Instruments PXI-4072 Frequently Asked Questions

 

Question: Can I use the PXI-4072 DMM to perform an overall impedance measurement of a circuit comprised of inductive, capacitive, and resistive elements?

Answer: No, the PXI-4072 DMM is not able to measure impedance. You can, however, calculate impedance by measuring resistance, capacitance, and inductance independently.

 

Question: What is the flexible resolution of the NI PXI-4072?

Answer: The NI PXI-4072 has a 10 to 23-bit flexible resolution.

 

Question: Can the National Instruments NI PXI-4072 acquire waveform rates?

Answer: Yes, the National Instruments NI PXI-4072 can acquire waveforms at sample rates up to 1.8 MS/s.

 

Question: Can the PXI-4072 be calibrated with PXI Drivers?

Answer: No, the PXI-4072 needs an option such as NI-DMM API for calibration.

  PXI-4072 PDF Manuals

  PXI-4072 Diagrams

Driver Downloads for PXI-4072






OS Compatibility:
Win XP 32-bit, Win 7 32-bit, Win 10 32-bit

 Download Version


Why Buy From Apex Waves:

Apex Waves Youtube Video

"The business transaction was super easy and friendly."


"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"


"They were very helpful to get me the test equipment that I need."



Delivery:    
UPS, FedEX and DHL – Free Ground on all orders
Overnight, Next Day Air or Expedited shipping options available
International delivery available
Same day shipping for in-stock on location
Warranty: All of our products are covered by our Apex Waves Warranty.
3 Year Warranty - New Surplus Parts
2 Year Warranty - Refurbished Parts
Returns: No hassle return policy.
Dedicated customer service team.
Payment: Authorize.net Visa Master Card American Express BB&T Better Business Bureau Dun & Bradstreet
Quick Quotes: Receive Price & Availability Today!
Calibration: Ask About Our Tiered Calibration Levels
Option & Modules: Confirm Your Requirements or Versions
Repair: Cost & Lead Time Available Upon Request for Service
Repair Evaluation: $150
Share this page: Facebook Icon Twitter Icon LinkedIn Icon
Common Typos: PAI-4072, PXI-R072, PXI-T072, PXI-4O72, PXI-40U2

PXI-4072



Meters > National Instruments > NI-407x Series

PXI-4072
4.9/5 | 10 ratings

PXI-4072, 6.5 Digit, ±300 V, PXI Digital Multimeter

In Stock | Ships Today
Same Day Calibration Available
2-3 Year Warranty Included
Free Ground Shipping
  Get Pricing

Call now for best pricing
1-800-915-6216

National Instruments PXI-4072 PXI Digital Multimeter

The National Instruments PXI-4072 (Part Number: 778270-01) FlexDMM gives the user the usefulness of three normal instruments in a solitary slot 3U PXI module: a 6½-digit multimeter, an LCR meter, and disengaged digitizer which has a maximum sample rate of 1.8 MS per second. The NI PXI-4072 FlexDMM brings computerized multimeters closer to providing universal estimation ability by offering the user the 20 most basic ATE estimations, including voltage, current, capacitance, inductance, temperature, and resistance. By coordinating these estimations into one PXI module, the user can diminish test framework size and cost, increment throughput, and abbreviate test development time. This model can likewise be utilized with PXI switches to frame a multichannel information obtaining framework.

These National Instruments PC-based advanced multimeters and LCR meters are upgraded for computerized test. Accessible on buses from USB to PXI, these DMMs consolidate offer more than 150 NI switch topology alternatives to make high-channel-count test frameworks. The device has a DC voltage range of -300 V to 300 V; and a DC current range of -1 A to 1 A. It is equipped with a 6.5 digit resolution. The PXI-4072 has a DC range/function change of 100/s, and an AC range/function change of 10/s. Additionally, the device has an operating ambient temperature range of 0 °C to 55 °C.

The device operates on the NI-DMM driver software. National Instruments NI PXI-4072 FlexDMM and LCR Meter drivers are minor programs that empower the Digital Multimeter to communicate with the working framework software. Keeping the NI PXI-4072 FlexDMM and LCR Meter software updated prevents crashes and amplifies equipment and framework execution. Utilizing obsolete or degenerate National Instruments PXI-4072 FlexDMM and LCR Meter drivers can cause framework blunders, crashes, and make your PC or equipment fail. Besides, introducing the wrong National Instruments drivers can aggravate these issues even more. Also, your computer should have one of the following configurations: a PCI slot, a x1, x4, x8, x16 PCI Express slot, a USB 2.0 or 1.1 slot, a PXI, PXI/CompactPCI, or PXI/SCXI combination chassis, chassis documentation, and a controller. Additional specifications for the PXI-4072 can be found in the user manuals and datasheets under the "Manuals & PDFs" tab.

PXI-4072 Maintenance Status has been announced by National Instruments, but the multimeter will still be available for purchase and repairs by Apex Waves.

ModelPXI-4072
ManufacturerNational Instruments
Part Number778270-01
HTS Code8471804000
TypePXI Digital Multimeter
Maximum Sample Rate1.8 MS/s
DC Voltage Range-300 V to 300 V
DC Current Range-1 A to 1 A
Digits of Resoution6.5
WarrantyThree Year Warranty
PXI-4072 ManualUser Manual and Maintenance Manual Available for Download
PriceContact a sales representative for a quote.

National Instruments PXI-4072 Frequently Asked Questions

 

Question: Can I use the PXI-4072 DMM to perform an overall impedance measurement of a circuit comprised of inductive, capacitive, and resistive elements?

Answer: No, the PXI-4072 DMM is not able to measure impedance. You can, however, calculate impedance by measuring resistance, capacitance, and inductance independently.

 

Question: What is the flexible resolution of the NI PXI-4072?

Answer: The NI PXI-4072 has a 10 to 23-bit flexible resolution.

 

Question: Can the National Instruments NI PXI-4072 acquire waveform rates?

Answer: Yes, the National Instruments NI PXI-4072 can acquire waveforms at sample rates up to 1.8 MS/s.

 

Question: Can the PXI-4072 be calibrated with PXI Drivers?

Answer: No, the PXI-4072 needs an option such as NI-DMM API for calibration.

Software & Drivers





OS Compatibility:
Win XP 32-bit, Win 7 32-bit, Win 10 32-bit

 Download Version

Why Buy From Apex Waves

Apex Waves Youtube Video

"The business transaction was super easy and friendly."


"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"


"They were very helpful to get me the test equipment that I need."


Delivery: UPS, FedEX and DHL – Free FedEx Ground on all orders
Overnight, Next Day Air or Expedited shipping options available
International delivery available
Same day shipping for in-stock on location
Warranty: All of our products are covered by our Apex Waves Warranty.
3 Year Warranty - New Surplus Parts
2 Year Warranty - Refurbished Parts
Returns: No hassle return policy.
Dedicated customer service team.
Payment: Authorize.Net paypal visa card master card american express card BB&T Bank better business bureau
Quick Quotes: Receive Price & Availability Today!
Calibration: Ask About Our Tiered Calibration Levels
Option & Modules: Confirm Your Requirements or Versions
Repair: Cost & Lead Time Available Upon Request for Service
Repair Evaluation: $150
Share this page: facebook twitter linkedIn