CAL-4330

Request for Availability

CAL-4330, 6.5 Digit, Calibration Fixture for Use With the PXIe-4330 and the PXIe-4331

Rated 4.7/5  |  11 ratings

❮ ❯

Actual item may vary if no part number is provided on quote request.

National Instruments - Accessories - CAL-4330
National Instruments - Accessories - CAL-4330 - Wiring
CAL-4330 New
CAL-4330 Refurbished

✔ 2 Year Warranty Included

✔ Free Domestic Ground Shipping

✔ NIST Calibration Available

Request a Quote

Get Price & Availability for the CAL-4330

Fast response from an Apex Waves specialist.

Fast Response Avg. 15 min
ISO 9001 Quality 2 Year Warranty
Check Availability Get Current Lead Time

National Instruments CAL-4330 Calibration Fixture

The National Instruments CAL-4330 (Part Numbers: 786988-01, 787003-01) Calibration Fixture is a vital component for preserving the precision and dependability of PXIe-4330 and PXIe-4331 devices. This fixture offers a controlled environment for testing and modifying different parameters, ensuring accurate calibration.

For optimal outcomes, use a Fluke 5520A/5522A calibrator with the CAL-4330. An alternate calibrator with similar specifications can be used if these particular models are not available. The necessary parameters are automated lead wire compensation, 2-wire output compensation, resistance values between 120 Ω and 1 kΩ with 0.01 Ω resolution, and an accuracy of 90 ppm or greater.

CAL-4330 comes with the cables needed to make connections easier. Two of these cables are 160-Pin DIN to 160-Pin DIN, which connect PXIe-2737 switch modules to the fixture. The other cable is a shielded cable (SH96F-96M-CAL4330), which connects the Device Under Test (DUT) to the CAL-4330.

Two DMMs, either PXI-4071 or PXIe-4081 devices, are among the test apparatus needed for calibration. These DMMs ought to be multiranging, with a 6 1/2-digit capability and an accuracy of at least 40 ppm for DC voltage and 80 ppm for resistance when measuring 4-wire resistance. Four PXIe-2737 switch modules are furthermore required for relay operations.

The CAL-4330 is designed to provide accurate readings in particular testing scenarios. It is advised to utilize twisted-pair wire to reduce noise and thermal offsets, use shielded copper wire for cable connections, and keep connections short to reduce noise interference. Stable operation conditions are achieved by keeping the relative humidity below 80% and the ambient temperature at 23°C ±5°C. In addition, it is advised to give the measurement circuitry at least 15 minutes to stabilize before running any experiments.

CAL-4330 Technical Specifications
ModelCAL-4330
Part Number(s)786988-01, 787003-01
ManufacturerNational Instruments (NI)
Compatible DevicesPXIe-4330, PXIe-4331
Calibrator CompatibilityFluke 5520A/5522A or equivalent
Cable (DIN to DIN)160-Pin, NI part number 782417-02 (x2)
Shielded Cable (DUT to CAL)SH96F-96M-CAL4330, NI part number 787003-01
DMM CompatibilityPXI-4071 or PXIe-4081 or equivalent
DMM Accuracy (DC Voltage)40 ppm of reading +6 ppm of range
DMM Accuracy (Resistance)80 ppm of reading +6 ppm of range
Switch ModulesPXIe-2737, 4x64 2-wire relay modules (x2)
Test ConditionsAmbient temperature: 23 °C ±5 °C, Relative humidity: <80%

Associated part numbers for CAL-4330:

National Instruments CAL-4330 Frequently Asked Questions

Why does the CAL-4330 have two part numbers?

Part number 786988-01 is the actual module, while Part number 787003-01 is a shielded cable for connecting the PXIe-4330/4331 to the CAL-4330.

Is the CAL-4330 compatible with other NI devices?

No, the CAL-4330 is specifically designed for the PXIe-4330/4331 modules.

What other devices are required to calibrate with the CAL-4330?

For optimal outcomes, use a Fluke 5520A/5522A calibrator with the CAL-4330. Two DMMs, either PXI-4071 or PXIe-4081 devices, are among the test apparatus needed for calibration. For relay operations, Four PXIe-2737 switch modules are furthermore required .

Delivery:

Free FedEx or UPS Ground shipping is offered on domestic orders. Expedited and international options are available; shipping other than domestic ground is customer-paid.

View shipping and delivery policy

All of our products are covered by our Apex Waves Warranty.

✓ 3 Year Warranty - New Surplus Parts

✓ 2 Year Warranty - Refurb / Fully Tested Parts

Eligible returns may be accepted within 30 days at Apex Waves’ discretion. A 25% restocking fee applies; non-refundable and built-to-order products are excluded.

View returns policy or submit a return request.

Payment:

Authorize.net Visa Master Card American Express Truist icon logo Better Business Bureau Dun & Bradstreet

Receive Price & Availability Today!

Ask About Our Tiered Calibration Levels

Option & Modules:

Confirm Your Requirements or Versions

Cost & Lead Time Available Upon Request for Service

Repair Evaluation: $150

Share this page:

Common Typos:

CQL-4330, CZL-4330, CXL-4330, CAO-4330, CAL-433P

Why Buy From Apex Waves:

Video thumbnail for Apex Waves Unboxing Experience Video