Modular Systems > National Instruments > FieldPoint

778069-30
778069-30 alt2
778069-30 New small
778069-30 Refurb small

Pictures shown are a representation. Actual item may vary if no part number is provided on quote request.

Same Day Calibration Available

2-3 Year Warranty Included

Free Ground Shipping

Or speak to a sales representative for additional information:

778069-30 Request for Availability

778069-30, Two Wire, 12 Bits, FP-RTD-PT100 RTD Input Module

Rated 4.9/5 | 10 ratings

Please fill out the form below to send in your quote request and a representative will contact you with a formal quote. View blog post on Model Name vs. Part Numbers

+Add more parts

Prefer to send a text message?

Text your name, e-mail, and parts to quote to:   1-919-809-5227

National Instruments 778069-30 RTD Input Module

Part Number 778069-30 is the identifying part number for the National Instruments FP-RTD-PT100 RTD Input Module. It is a two-wire 100 Ω Platinum RTD input module capable of providing 12-bit resolution measurements. The 778069-30 is designed with the linearization curves of a DIN 43760 standard RTD, where the temperature coefficient of resistance equals 0.00385. Note that each channel can be programmed for either degree Celsius or degree Fahrenheit range. 

The 778069-30 has two terminals per channel, where the negative terminal, or the “b” terminal, is common for both channels. If your application requires channel-to-channel isolation, you must use only one channel of each module. The RTD Input Module has an input impedance of 100 Ω and an excitation current of 550 µA. The measurement bandwidth of the RTD inputs is 15 Hz and the step response time is 42 ms. Furthermore, there is an input protection of ±6 V for these types of inputs. Moreover, the module has a power requirement of 375 mW max. The 778069-30 supports temperature inputs between –50 to 350 °C or  –58 to 662 °F, with a resolution of 0.1 °C or 0.18 °F. The accuracy of the module at 25°C is 0.2 °C or 0.4 °F. The temperature drift, which is the sum of the offset and gain per degree is 0.03 °C + 100 ppm or 0.06 °F + 100 ppm.

The 778069-30 is designed to fit into a FieldPoint Terminal Base, like the FP-TB-10. This terminal base has a power requirement of 200 mW. On the other hand, the module is recommended for operation in between temperature ranges of -40 to 70 °C at a relative humidity of 10 to 90%. However, it can be stored in a wider temperature range of -40 to 85 °C. The RTD module typically weighs 60 g and when fit inside the terminal base of weight 290 g, it leads to a total weight of about 350 g. The modules are designed to meet the requirements of the following safety standards: IEC 61010-1, EN 61010-1, UL 3121-1, UL 61010C-1, and CAN/CSA C22.2 No. 1010.1.

Part Number778069-30
Model NameFP-RTD-PT100
Part TypeRTD Input Module
Number of RTD Input Channels2
Input Resolution12 bits
Measurement Bandwidth15 Hz
Input Protection±6 V
Input

Associated part numbers for 778069-30:

Delivery:

UPS, FedEX and DHL – Free Ground on all orders

Overnight, Next Day Air or Expedited shipping options available

International delivery available

Same day shipping for in-stock on location

Warranty:

All of our products are covered by our Apex Waves Warranty.

3 Year Warranty - New Surplus Parts

2 Year Warranty - Refurbished Parts

Returns:

No hassle return policy.

Dedicated customer service team.

Payment:

Authorize.net Visa Master Card American Express BB&T Better Business Bureau Dun & Bradstreet

Quick Quotes:

Receive Price & Availability Today!

Calibration:

Ask About Our Tiered Calibration Levels

Option & Modules:

Confirm Your Requirements or Versions

Repair:

Cost & Lead Time Available Upon Request for Service

Repair Evaluation: $150

Share this page:

Common Typos:

U78069-30, 7Y8069-30, 7U8069-30, 77U069-30, 778069-3O
Why Buy From Apex Waves: