Modular Systems > National Instruments > SCXI




Pictures shown are a representation. Actual item may vary if no part number is provided on quote request.
✔ Same Day Calibration Available
✔ 2-3 Year Warranty Included
✔ Free Ground Shipping
Or speak to a sales representative for additional information:
Phone:
1-800-915-6216Email:
sales@apexwaves.comSCXI-1350 Request for Availability
SCXI-1350, Daisy-Chains to SCXI-1001, Multichassis Adapter
National Instruments SCXI-1350 Multichassis Adapter
The NI SCXI-1350 (Part Number: 776575-50) requires an SCXI chassis, SCXI modules, a data acquisition board, cables, a computer, and a small flathead screwdriver to use the Adapter. This Multichassis Adapter allows the user to link a multichassis system to a data acquisition board. The following modules can be used with the SCXI 1350: the SCXI-1163, SCXI-1100, SCXI-1162, SCXI-1120, SCXI-1161, SCXI-1140, SCXI-1160, and SCXI-1121. In addition, the SCXI-1181 Breadboard Module and the SCXI-1180 Feedthrough Panel can be linked to any data acquisition board via a 50-pin or 100-pin ribbon cable.
This Multichassis Adapter has a male back connector, a female module connector, and a male chassis extender connector. The user can utilize a ribbon cable to link the back connector to the data acquisition board or a previous chassis. The module connector inserts into the back signal connector of an SCXI module, while another ribbon cable links the chassis connector to the Multichassis Adapter in the following chassis.
One example of the connections the NI SCXI-1350 is capable of includes linking a three-chassis system with an AT-MIO-16 data acquisition board. For this type of linking, three NBI cables and three National Instruments SCXI 1350 Multichassis Adapters are necessary. The user should keep in mind that if they are cabling a system with a DIO data acquisition board, then the DIO board will control all the chassis. However, several of the spare DIO lines will be jumbled. When the user is cabling a system with an MIO data acquisition board, the Multichassis Adapters link analog channel 0 of the MIO board to the analog output of the initial chassis. Analog channel 1 of the MIO board is linked to the analog output of the second chassis, and so on.
SCXI-1350 Obsolete Status has been announced by National Instruments, but the Multichassis Adapter will still be available for purchase and repairs by Apex Waves.
Model | SCXI-1350 |
---|---|
Manufacturer | National Instruments |
Part Number | 776575-50 |
Type | Multichassis Adapter |
For Use With: | SCXI-1001 |
Cables | 50-pin or 100-pin ribbon cables |
Warranty | 2-3 Year Warranty |
SCXI-1350 Manual | User Manual and Maintenance Manual Available for Download |
Price | Contact a sales representative for a quote. |
Associated part numbers for SCXI-1350:
National Instruments SCXI-1350 Frequently Asked Questions
Question: Which data acquisition boards can be used with the SCXI-1350?
Answer: The following data acquisition boards can be used with the SCXI-1350: the AT-MIO-16, AT-MIO-16D, AT-MIO-16F-5, AT-MIO-16X, AT-MIO-64F-5, MC-DIO-24, MC-MIO-16, NB-DIO-24, NB-DIO-96, NB-MIO-16, NB-MIO-16X, PC-DIO-24, and PC-DIO-96.
Question: Are there any chassis that cannot be used in a multichassis system with the SCXI-1350?
Answer: The SCXI-1000 chassis cannot be used in a multichassis system.
Question: Where can I find the pin translations for the NI SCXI-1350?
Answer: The NI SCXI-1350 pin translations can be located in the user manual.
Delivery:
Warranty:
All of our products are covered by our Apex Waves Warranty.
✓ 3 Year Warranty - New Surplus Parts
✓ 2 Year Warranty - Refurbished Parts
Returns:
No hassle return policy.
Dedicated customer service team.
Quick Quotes:
Receive Price & Availability Today!
Calibration:
Ask About Our Tiered Calibration Levels
Option & Modules:
Confirm Your Requirements or Versions
Repair:
Cost & Lead Time Available Upon Request for Service
Repair Evaluation: $150
Common Typos: