SCXI-1350 National Instruments Multichassis Adapter | Apex Waves | ImageSCXI-1350 National Instruments Multichassis Adapter | Apex Waves | ImageSCXI-1350 NewSCXI-1350 | Legacy, Refurbished and New Surplus
SCXI-1350 National Instruments Multichassis Adapter | Apex Waves | Image
SCXI-1350 National Instruments Multichassis Adapter | Apex Waves | Image
SCXI-1350 New
SCXI-1350 | Legacy, Refurbished and New Surplus

SCXI-1350

5/5 | 9 ratings

Modular Systems > National Instruments > SCXI

Part Number SCXI-1350
Manufacturer/Brand National Instruments
Description: SCXI-1350, Daisy-Chains to SCXI-1001, Multichassis Adapter
Request for Availablility
Fast Quote
Quoted Price
Same Day Calibration Available
2-3 Year Warranty Included
Free Ground Shipping
  Get Pricing

Need an Official Quote?

 

Or speak to a sales representative for additional information:


National Instruments SCXI-1350 Multichassis Adapter

The NI SCXI-1350 (Part Number: 776575-50) requires an SCXI chassis, SCXI modules, a data acquisition board, cables, a computer, and a small flathead screwdriver to use the Adapter. This Multichassis Adapter allows the user to link a multichassis system to a data acquisition board. The following modules can be used with the SCXI 1350: the SCXI-1163, SCXI-1100, SCXI-1162, SCXI-1120, SCXI-1161, SCXI-1140, SCXI-1160, and SCXI-1121. In addition, the SCXI-1181 Breadboard Module and the SCXI-1180 Feedthrough Panel can be linked to any data acquisition board via a 50-pin or 100-pin ribbon cable.

This Multichassis Adapter has a male back connector, a female module connector, and a male chassis extender connector. The user can utilize a ribbon cable to link the back connector to the data acquisition board or a previous chassis. The module connector inserts into the back signal connector of an SCXI module, while another ribbon cable links the chassis connector to the Multichassis Adapter in the following chassis.

One example of the connections the NI SCXI-1350 is capable of includes linking a three-chassis system with an AT-MIO-16 data acquisition board. For this type of linking, three NBI cables and three National Instruments SCXI 1350 Multichassis Adapters are necessary. The user should keep in mind that if they are cabling a system with a DIO data acquisition board, then the DIO board will control all the chassis. However, several of the spare DIO lines will be jumbled.  When the user is cabling a system with an MIO data acquisition board, the Multichassis Adapters link analog channel 0 of the MIO board to the analog output of the initial chassis. Analog channel 1 of the MIO board is linked to the analog output of the second chassis, and so on.

SCXI-1350 Obsolete Status has been announced by National Instruments, but the Multichassis Adapter will still be available for purchase and repairs by Apex Waves.

ModelSCXI-1350
ManufacturerNational Instruments
Part Number776575-50
TypeMultichassis Adapter
For Use With:SCXI-1001
Cables50-pin or 100-pin ribbon cables
Warranty2-3 Year Warranty
SCXI-1350 ManualUser Manual and Maintenance Manual Available for Download
PriceContact a sales representative for a quote.

Associated part numbers for the SCXI-1350:

181750-01, 776575-50

National Instruments SCXI-1350 Frequently Asked Questions

 

Question: Which data acquisition boards can be used with the SCXI-1350?

 

Answer: The following data acquisition boards can be used with the SCXI-1350: the AT-MIO-16, AT-MIO-16D, AT-MIO-16F-5, AT-MIO-16X, AT-MIO-64F-5, MC-DIO-24, MC-MIO-16, NB-DIO-24, NB-DIO-96, NB-MIO-16, NB-MIO-16X, PC-DIO-24, and PC-DIO-96.

 

Question: Are there any chassis that cannot be used in a multichassis system with the SCXI-1350?

 

Answer: The SCXI-1000 chassis cannot be used in a multichassis system.

 

Question: Where can I find the pin translations for the NI SCXI-1350?

 

Answer: The NI SCXI-1350 pin translations can be located in the user manual.


Why Buy From Apex Waves:

Apex Waves Youtube Video

"The business transaction was super easy and friendly."


"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"


"They were very helpful to get me the test equipment that I need."



Delivery:    
UPS, FedEX and DHL – Free Ground on all orders
Overnight, Next Day Air or Expedited shipping options available
International delivery available
Same day shipping for in-stock on location
Warranty: All of our products are covered by our Apex Waves Warranty.
3 Year Warranty - New Surplus Parts
2 Year Warranty - Refurbished Parts
Returns: No hassle return policy.
Dedicated customer service team.
Payment: Authorize.net Visa Master Card American Express BB&T Better Business Bureau Dun & Bradstreet
Quick Quotes: Receive Price & Availability Today!
Calibration: Ask About Our Tiered Calibration Levels
Option & Modules: Confirm Your Requirements or Versions
Repair: Cost & Lead Time Available Upon Request for Service
Repair Evaluation: $150
Share this page: Facebook Icon Twitter Icon LinkedIn Icon
Common Typos: WCXI-1350, SCZI-1350, SCXI-W350, SCXI-1E50, SCXI-13T0

SCXI-1350



Modular Systems > National Instruments > SCXI

SCXI-1350
5/5 | 9 ratings

SCXI-1350, Daisy-Chains to SCXI-1001, Multichassis Adapter

Request for Availablility
Same Day Calibration Available
2-3 Year Warranty Included
Free Ground Shipping
  Get Pricing

Call now for best pricing
1-800-915-6216

National Instruments SCXI-1350 Multichassis Adapter

The NI SCXI-1350 (Part Number: 776575-50) requires an SCXI chassis, SCXI modules, a data acquisition board, cables, a computer, and a small flathead screwdriver to use the Adapter. This Multichassis Adapter allows the user to link a multichassis system to a data acquisition board. The following modules can be used with the SCXI 1350: the SCXI-1163, SCXI-1100, SCXI-1162, SCXI-1120, SCXI-1161, SCXI-1140, SCXI-1160, and SCXI-1121. In addition, the SCXI-1181 Breadboard Module and the SCXI-1180 Feedthrough Panel can be linked to any data acquisition board via a 50-pin or 100-pin ribbon cable.

This Multichassis Adapter has a male back connector, a female module connector, and a male chassis extender connector. The user can utilize a ribbon cable to link the back connector to the data acquisition board or a previous chassis. The module connector inserts into the back signal connector of an SCXI module, while another ribbon cable links the chassis connector to the Multichassis Adapter in the following chassis.

One example of the connections the NI SCXI-1350 is capable of includes linking a three-chassis system with an AT-MIO-16 data acquisition board. For this type of linking, three NBI cables and three National Instruments SCXI 1350 Multichassis Adapters are necessary. The user should keep in mind that if they are cabling a system with a DIO data acquisition board, then the DIO board will control all the chassis. However, several of the spare DIO lines will be jumbled.  When the user is cabling a system with an MIO data acquisition board, the Multichassis Adapters link analog channel 0 of the MIO board to the analog output of the initial chassis. Analog channel 1 of the MIO board is linked to the analog output of the second chassis, and so on.

SCXI-1350 Obsolete Status has been announced by National Instruments, but the Multichassis Adapter will still be available for purchase and repairs by Apex Waves.

ModelSCXI-1350
ManufacturerNational Instruments
Part Number776575-50
TypeMultichassis Adapter
For Use With:SCXI-1001
Cables50-pin or 100-pin ribbon cables
Warranty2-3 Year Warranty
SCXI-1350 ManualUser Manual and Maintenance Manual Available for Download
PriceContact a sales representative for a quote.

National Instruments SCXI-1350 Frequently Asked Questions

 

Question: Which data acquisition boards can be used with the SCXI-1350?

 

Answer: The following data acquisition boards can be used with the SCXI-1350: the AT-MIO-16, AT-MIO-16D, AT-MIO-16F-5, AT-MIO-16X, AT-MIO-64F-5, MC-DIO-24, MC-MIO-16, NB-DIO-24, NB-DIO-96, NB-MIO-16, NB-MIO-16X, PC-DIO-24, and PC-DIO-96.

 

Question: Are there any chassis that cannot be used in a multichassis system with the SCXI-1350?

 

Answer: The SCXI-1000 chassis cannot be used in a multichassis system.

 

Question: Where can I find the pin translations for the NI SCXI-1350?

 

Answer: The NI SCXI-1350 pin translations can be located in the user manual.

Why Buy From Apex Waves

Apex Waves Youtube Video

"The business transaction was super easy and friendly."


"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"


"They were very helpful to get me the test equipment that I need."


Delivery: UPS, FedEX and DHL – Free FedEx Ground on all orders
Overnight, Next Day Air or Expedited shipping options available
International delivery available
Same day shipping for in-stock on location
Warranty: All of our products are covered by our Apex Waves Warranty.
3 Year Warranty - New Surplus Parts
2 Year Warranty - Refurbished Parts
Returns: No hassle return policy.
Dedicated customer service team.
Payment: Authorize.Net paypal visa card master card american express card BB&T Bank better business bureau
Quick Quotes: Receive Price & Availability Today!
Calibration: Ask About Our Tiered Calibration Levels
Option & Modules: Confirm Your Requirements or Versions
Repair: Cost & Lead Time Available Upon Request for Service
Repair Evaluation: $150
Share this page: facebook twitter linkedIn