P5002A

Request for Availability

Keysight/Agilent P5002A, 1 Source, 2 Ports, 9 GHz Maximum Frequency, Streamline USB Vector Network Analyzer

Rated 5/5  |  20 ratings

❮ ❯

Actual item may vary if no part number is provided on quote request.

Keysight Agilent HP - Vector Network Analyzers - P5002A
Keysight Agilent HP - Vector Network Analyzers - P5002A - Wiring
P5002A New
P5002A Refurbished

✔ 2 Year Warranty Included

✔ Free Domestic Ground Shipping

✔ NIST Calibration Available

Request a Quote

Get Price & Availability for the P5002A

Fast response from an Apex Waves specialist.

Fast Response Avg. 15 min
ISO 9001 Quality 2 Year Warranty
Check Availability Get Current Lead Time

Keysight/Agilent P5002A Streamline USB Vector Network Analyzer

The Keysight P5002A Streamline USB Vector Network Analyzer covers a frequency range of 9 kHz to 9 GHz. It provides a frequency resolution of 1 Hz for highly precise and repeatable signal characterization. The frequency accuracy is rated at ±7 ppm at an operating temperature of 25 ± 5 °C. The model features two built-in test ports and a single measurement source for comprehensive RF testing. The analyzer delivers corrected directivity of 49 dB across the 9 kHz to 50 MHz frequency band. From 50 MHz to 3 GHz, the corrected directivity specification is maintained at 46 dB. The directivity performance is rated at 40 dB in the 3 GHz to 6 GHz range. The corrected directivity is specified at 38 dB in the 6 GHz to 9 GHz band.

The corrected source match for the P5002A USB Vector Network Analyzer measures 41 dB in the 9 kHz to 50 MHz band. The source match reduces to 35 dB in the 6 GHz to 9 GHz upper range. The corrected load match is rated at 47 dB in the 9 kHz to 50 MHz band. The load match performance drops to 38 dB in the 6 GHz to 9 GHz frequency range. The reflection tracking for the network analyzer is specified at ± 0.011 dB in the 9 kHz to 50 MHz range. It reaches ± 0.032 dB in the 3 GHz to 6 GHz band and ± 0.054 dB above 6 GHz. The transmission tracking is rated at ± 0.082 dB in the lowest band and ± 0.021 dB at mid-range frequencies. The transmission tracking spans from ± 0.063 dB to ± 0.074 dB in the 3 GHz to 9 GHz range.

The maximum output port power for the Keysight Streamline USB Vector Network Analyzer reaches 10 dBm from 10 MHz to 4.5 GHz. From 4.5 GHz to 6.5 GHz, the specified output power is maintained at 10 dBm. The output power specification is rated at 9 dBm in the 6.5 GHz to 9 GHz range. The output power specification begins at 0 dBm at lower frequencies from 9 kHz to 100 kHz.

P5002A Technical Specifications
ModelP5002A
ManufacturerKeysight/Agilent
Part TypeStreamline USB Vector Network Analyzer, 9 GHz
Frequency Range9 kHz To 9 GHz
Device TypeCompact High-Performance VNA
Application FlexibilityWide RF Measurement Applications
User InterfaceSame As PNA GUI
Calibration SupportSupports eCal modules.
Pulsed RF MeasurementsBasic Pulsed-RF Measurements

Associated part numbers for P5002A:

Delivery:

Free FedEx or UPS Ground shipping is offered on domestic orders. Expedited and international options are available; shipping other than domestic ground is customer-paid.

View shipping and delivery policy

All of our products are covered by our Apex Waves Warranty.

✓ 3 Year Warranty - New Surplus Parts

✓ 2 Year Warranty - Refurb / Fully Tested Parts

Eligible returns may be accepted within 30 days at Apex Waves’ discretion. A 25% restocking fee applies; non-refundable and built-to-order products are excluded.

View returns policy or submit a return request.

Payment:

Authorize.net Visa Master Card American Express Truist icon logo Better Business Bureau Dun & Bradstreet

Receive Price & Availability Today!

Ask About Our Tiered Calibration Levels

Option & Modules:

Confirm Your Requirements or Versions

Cost & Lead Time Available Upon Request for Service

Repair Evaluation: $150

Share this page:

Common Typos:

PR002A, PT002A, P50O2A, P500QA, P500EA

Why Buy From Apex Waves:

Video thumbnail for Apex Waves Unboxing Experience Video