cDAQ-9134
Modular Systems > National Instruments > CompactDAQ
Description: | cDAQ-9134, 32 GB, 4-Slot, CompactDAQ Controller |
Need an Official Quote?
Or speak to a sales representative for additional information:
National Instruments cDAQ-9134 CompactDAQ Controller
The cDAQ-9134 is a CompactDAQ Controller by National Instruments. The cDAQ-9134 comes in 2 versions. The only difference in these versions is the Controller OS. The part number of the cDAQ-9134 with Windows is 783340-01, while the part number with Linux RT is 783341-01. This model is a C Series, dual-core DAQ Controller used for signal acquisition and data transfer. This model offers inline software analysis while transferring data. The cDAQ-9134 is designed to withstand extreme environments. This Controller is used to design customized logging and measurement systems. The cDAQ-9134 can interface up to four C Series devices simultaneously.
The cDAQ-9134 CompactDAQ Controller comes with an Intel Atom E3825 processor. The frequency of the Intel E3825 is 1.33 GHz. The cDAQ 9134 has 2 Ethernet ports. These ports support cable lengths up to 100 m. This model also features three standard USB ports. The USB ports support a maximum data rate of 480 Mbps. The NI cDAQ-9134 also has a display port with a maximum supported resolution of 2560 x 1600. This device has an internal memory of 32 GB. The cDAQ-9134 also supports a removable SD memory of 32 GB. This model supports both SD and SDHC type memory cards.
The cDAQ-9134 CompactDAQ Controller features four 32-bit general-purpose timers/counters. These counters support two types of base clocks. The internal base clocks feature frequencies of 100 kHz, 20 MHz, and 80 MHz. An external base clock can also be used with the NI cDAQ-9134. The supported range of the external frequency is 0 to 20 MHz. This model also has a frequency generator with a base clock accuracy of 50 ppm.
Model | cDAQ-9134 |
---|---|
Manufacturer | National Instruments |
Part Numbers | 783340-01, 783341-01 |
Type | CompactDAQ Controller |
Slots | 4 |
Hard Drive Memory Size | 32 GB |
Processor Core | 1.33 GHz Dual Core Intel Atom |
Dimensions | 8.64 x 3.47 x 4.67 in. |
Weight | 4 lb, 1.3 oz. |
Warranty | 2-3 Year Warranty |
cDAQ-9134 Manual | User Manual and Maintenance Manual Available for Download |
Price | Contact a sales representative for a quote. |
Associated part numbers for the cDAQ-9134:
155470A-11L, 155470A-21L, 155470B-11L, 155470B-99L, 155620A-11L, 155620B-11L, 155620C-11L, 156210A-11L, 156210A-12L, 156210B-11L, 156210B-12L, 156210C-11L, 156210C-12L, 156210D-11L, 156210D-12L, 156210E-11L, 156210E-12L, 156210F-11L, 156210F-12L, 156210G-11L, 156210G-12L, 783340-01, 783341-01
National Instruments cDAQ-9134 Frequently Asked Questions
Question: I see two different part numbers for the cDAQ 9134. What does this mean?
Answer: The cDAQ 9134 has two versions, which are each compatible with a different operating system. Part number 783340-01 is compatible with Windows Embedded Standard 7 OS, whereas part number 783341-01 is compatible with NI Linux Real Time OS.
Question: I’m using a cDAQ-9134 with embedded Windows and a touch screen. The touch screen is connected and working, but the computer is not recognizing it. How do I get it to show up?
Answer: If you’re running a cDAQ-9134 and the touch screen is working, but not showing up in the computer, it sounds like the touch screen needs to be calibrated. Follow the instructions provided by the computer manufacturer on calibrating touch screens.
Question: Can I use a GigE camera on my NI cDAQ-9134 with Windows OS?
Answer: Yes, it's possible to use a GigE camera on NI cDAQ-9134 if the camera is GigE Vision standard compliant.
Question: How can I activate the two USER LEDs (USER1 and USER2) on my NI cDAQ 9134?
Answer: With the NI cDAQ 9134, it is not possible to set the USER LEDS with an outdated version of LabVIEW. Ensure that your LabVIEW is updated.
cDAQ-9134 PDF Manuals
NI CDAQ 9132 9134 9136 FOR LABVIEW REAL TIME QUICK START.PDF
NI CDAQ 9132 9134 9136 FOR WINDOWS QUICK START.PDF
NI CDAQ 9132 NI CDAQ 9134 LETTER OF VOLATILITY.PDF
NI CDAQ 9134 SAFETY ENVIRONMENTAL AND REGULATORY INFORMATION.PDF
CDAQ CHASSIS AND CONTROLLERS CALIBRATION PROCEDURE.PDF
Driver Downloads for cDAQ-9134
OS Compatibility:
Win XP 32-bit, Win 7 32-bit, Win 10 32-bit
Why Buy From Apex Waves:
"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"
"They were very helpful to get me the test equipment that I need."
cDAQ-9134
Modular Systems > National Instruments > CompactDAQ
1-800-915-6216
- Description
- Technical Specifications
- FAQ
- Manuals & PDFs
- Drivers
National Instruments cDAQ-9134 CompactDAQ Controller
The cDAQ-9134 is a CompactDAQ Controller by National Instruments. The cDAQ-9134 comes in 2 versions. The only difference in these versions is the Controller OS. The part number of the cDAQ-9134 with Windows is 783340-01, while the part number with Linux RT is 783341-01. This model is a C Series, dual-core DAQ Controller used for signal acquisition and data transfer. This model offers inline software analysis while transferring data. The cDAQ-9134 is designed to withstand extreme environments. This Controller is used to design customized logging and measurement systems. The cDAQ-9134 can interface up to four C Series devices simultaneously.
The cDAQ-9134 CompactDAQ Controller comes with an Intel Atom E3825 processor. The frequency of the Intel E3825 is 1.33 GHz. The cDAQ 9134 has 2 Ethernet ports. These ports support cable lengths up to 100 m. This model also features three standard USB ports. The USB ports support a maximum data rate of 480 Mbps. The NI cDAQ-9134 also has a display port with a maximum supported resolution of 2560 x 1600. This device has an internal memory of 32 GB. The cDAQ-9134 also supports a removable SD memory of 32 GB. This model supports both SD and SDHC type memory cards.
The cDAQ-9134 CompactDAQ Controller features four 32-bit general-purpose timers/counters. These counters support two types of base clocks. The internal base clocks feature frequencies of 100 kHz, 20 MHz, and 80 MHz. An external base clock can also be used with the NI cDAQ-9134. The supported range of the external frequency is 0 to 20 MHz. This model also has a frequency generator with a base clock accuracy of 50 ppm.
Model | cDAQ-9134 |
---|---|
Manufacturer | National Instruments |
Part Numbers | 783340-01, 783341-01 |
Type | CompactDAQ Controller |
Slots | 4 |
Hard Drive Memory Size | 32 GB |
Processor Core | 1.33 GHz Dual Core Intel Atom |
Dimensions | 8.64 x 3.47 x 4.67 in. |
Weight | 4 lb, 1.3 oz. |
Warranty | 2-3 Year Warranty |
cDAQ-9134 Manual | User Manual and Maintenance Manual Available for Download |
Price | Contact a sales representative for a quote. |
National Instruments cDAQ-9134 Frequently Asked Questions
Question: I see two different part numbers for the cDAQ 9134. What does this mean?
Answer: The cDAQ 9134 has two versions, which are each compatible with a different operating system. Part number 783340-01 is compatible with Windows Embedded Standard 7 OS, whereas part number 783341-01 is compatible with NI Linux Real Time OS.
Question: I’m using a cDAQ-9134 with embedded Windows and a touch screen. The touch screen is connected and working, but the computer is not recognizing it. How do I get it to show up?
Answer: If you’re running a cDAQ-9134 and the touch screen is working, but not showing up in the computer, it sounds like the touch screen needs to be calibrated. Follow the instructions provided by the computer manufacturer on calibrating touch screens.
Question: Can I use a GigE camera on my NI cDAQ-9134 with Windows OS?
Answer: Yes, it's possible to use a GigE camera on NI cDAQ-9134 if the camera is GigE Vision standard compliant.
Question: How can I activate the two USER LEDs (USER1 and USER2) on my NI cDAQ 9134?
Answer: With the NI cDAQ 9134, it is not possible to set the USER LEDS with an outdated version of LabVIEW. Ensure that your LabVIEW is updated.
cDAQ-9134 PDF Manuals & Diagrams
cDAQ-9134 PDF Manuals
NI CDAQ 9132 9134 9136 FOR LABVIEW REAL TIME QUICK START.PDF
NI CDAQ 9132 9134 9136 FOR WINDOWS QUICK START.PDF
NI CDAQ 9132 NI CDAQ 9134 LETTER OF VOLATILITY.PDF
NI CDAQ 9134 SAFETY ENVIRONMENTAL AND REGULATORY INFORMATION.PDF
CDAQ CHASSIS AND CONTROLLERS CALIBRATION PROCEDURE.PDF
Why Buy From Apex Waves
"The business transaction was super easy and friendly."
"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"
"They were very helpful to get me the test equipment that I need."