Part Number FP-2010
Manufacturer/Brand National Instruments
Description: FP-2010, 64 MB nonvolatile memory, 32 MB DRAM, LabVIEW Real-Time Controller Interface
In Stock | Ships Today
Fast Quote
Quoted Price
Same Day Calibration Available
2-3 Year Warranty Included
Free Ground Shipping
  Get Pricing

Need an Official Quote?

 

Or speak to a sales representative for additional information:


National Instruments FP-2010 LabVIEW Real-Time Controller Interface

The FP-2010 (Part Number: 777792-21) supplies 9 W of capacity to the I/O modules. Utilizing certain I/O modules that expend in excess of 1 W may lessen the aggregate number of I/O modules permitted in the bank to under nine. This demonstrates the FP-2010 is prepared to be arranged and the user can continue to introduce the FieldPoint programming. The user can constrain have access to the FP-2010 by setting access authorizations for various host machines. The default setting permits Read/Write access to all host machines. After the user designs the FP-2010, they can secure the settings made with Remote System Explorer with a secret phrase to keep others on the system from changing the arrangement. Also, a host PC on the system cannot target LabVIEW RT to the FP-2010 without a secret phrase except if the host is in the RT Target: Access list.

The FP-2010 LabVIEW Real-Time Controller Interface coordinates effortlessly with National Instruments Lookout 4.0 and later. The user can get to the module a similar way they would get to another PC running Lookout. It is possible to access the channel information, ranges, traits, and directions from Lookout, and a few control factors, for example, Reset and Snapshot.

This model offers a stand-alone implanted ongoing controller or Ethernet interface for PC-based dispersed I/O, 32 MB DRAM memory for cutting edge applications (commonly 24 MB client open), 64 MB nonvolatile memory (normally 56 MB client available), support for LabVIEW Real-Time Module 8.5.1 and prior, and support for Windows Vista and prior.

FP-2010 Obsolete Status has been announced by National Instruments, but will still be available for purchase and repairs by Apex Waves.

ModelFP-2010
ManufacturerNational Instruments
Part Number777792-21
TypeLabVIEW Real-Time Controller Interface
Ethernet Ports1
Serial Ports1
DRAM Memory32 MB
Nonvolatile Storage64 MB
Weight9.8 oz.
Warranty2-3 Year Warranty
FP-2010 ManualUser Manual and Maintenance Manual Available for Download
PriceContact a sales representative for a quote.

Associated part numbers for the FP-2010:

1876.85, 187685A-02, 187685B-02, 187685C-02, 187685D-02, 187685F-02, 187685G-02, 187685H-02, 188157C-02, 777792-21

National Instruments FP-2010 Frequently Asked Questions

 

Question: What does it mean when the STATUS LED is red on the FP-2010?

 

Answer: On the FP-2010, when the STATUS LED is red it means there is a failure condition.

 

Question: Which software is compatible with the NI FP-2010?

 

Answer: The following software is compatible with the NI FP-2010 and suggested for use with the Controller: LabVIEW, the LabVIEW Real-Time Module, and the LabVIEW Datalogging and Supervisory Control Module. Other compatible software includes LabWindows/CVI, VI Logger, Lookout, and Measurement Studio.

 

Question: What type of screw terminal wiring does the FP-2010 have?

 

Answer: The FP-2010 has 16–26 AWG copper conductor wire with 7 mm (0.28 in.) of insulation stripped from the end for screw-terminal wiring.

  FP-2010 PDF Manuals


Why Buy From Apex Waves:

Apex Waves Youtube Video

"The business transaction was super easy and friendly."


"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"


"They were very helpful to get me the test equipment that I need."



Delivery:    
UPS, FedEX and DHL – Free Ground on all orders
Overnight, Next Day Air or Expedited shipping options available
International delivery available
Same day shipping for in-stock on location
Warranty: All of our products are covered by our Apex Waves Warranty.
3 Year Warranty - New Surplus Parts
2 Year Warranty - Refurbished Parts
Returns: No hassle return policy.
Dedicated customer service team.
Payment: Authorize.net Visa Master Card American Express BB&T Better Business Bureau Dun & Bradstreet
Quick Quotes: Receive Price & Availability Today!
Calibration: Ask About Our Tiered Calibration Levels
Option & Modules: Confirm Your Requirements or Versions
Repair: Cost & Lead Time Available Upon Request for Service
Repair Evaluation: $150
Share this page: Facebook Icon Twitter Icon LinkedIn Icon
Common Typos: DP-2010, TP-2010, VP-2010, FP-201O, FP-201P

FP-2010



Modular Systems > National Instruments > FieldPoint

FP-2010
4.9/5 | 7 ratings

FP-2010, 64 MB nonvolatile memory, 32 MB DRAM, LabVIEW Real-Time Controller Interface

In Stock | Ships Today
Same Day Calibration Available
2-3 Year Warranty Included
Free Ground Shipping
  Get Pricing

Call now for best pricing
1-800-915-6216

National Instruments FP-2010 LabVIEW Real-Time Controller Interface

The FP-2010 (Part Number: 777792-21) supplies 9 W of capacity to the I/O modules. Utilizing certain I/O modules that expend in excess of 1 W may lessen the aggregate number of I/O modules permitted in the bank to under nine. This demonstrates the FP-2010 is prepared to be arranged and the user can continue to introduce the FieldPoint programming. The user can constrain have access to the FP-2010 by setting access authorizations for various host machines. The default setting permits Read/Write access to all host machines. After the user designs the FP-2010, they can secure the settings made with Remote System Explorer with a secret phrase to keep others on the system from changing the arrangement. Also, a host PC on the system cannot target LabVIEW RT to the FP-2010 without a secret phrase except if the host is in the RT Target: Access list.

The FP-2010 LabVIEW Real-Time Controller Interface coordinates effortlessly with National Instruments Lookout 4.0 and later. The user can get to the module a similar way they would get to another PC running Lookout. It is possible to access the channel information, ranges, traits, and directions from Lookout, and a few control factors, for example, Reset and Snapshot.

This model offers a stand-alone implanted ongoing controller or Ethernet interface for PC-based dispersed I/O, 32 MB DRAM memory for cutting edge applications (commonly 24 MB client open), 64 MB nonvolatile memory (normally 56 MB client available), support for LabVIEW Real-Time Module 8.5.1 and prior, and support for Windows Vista and prior.

FP-2010 Obsolete Status has been announced by National Instruments, but will still be available for purchase and repairs by Apex Waves.

ModelFP-2010
ManufacturerNational Instruments
Part Number777792-21
TypeLabVIEW Real-Time Controller Interface
Ethernet Ports1
Serial Ports1
DRAM Memory32 MB
Nonvolatile Storage64 MB
Weight9.8 oz.
Warranty2-3 Year Warranty
FP-2010 ManualUser Manual and Maintenance Manual Available for Download
PriceContact a sales representative for a quote.

National Instruments FP-2010 Frequently Asked Questions

 

Question: What does it mean when the STATUS LED is red on the FP-2010?

 

Answer: On the FP-2010, when the STATUS LED is red it means there is a failure condition.

 

Question: Which software is compatible with the NI FP-2010?

 

Answer: The following software is compatible with the NI FP-2010 and suggested for use with the Controller: LabVIEW, the LabVIEW Real-Time Module, and the LabVIEW Datalogging and Supervisory Control Module. Other compatible software includes LabWindows/CVI, VI Logger, Lookout, and Measurement Studio.

 

Question: What type of screw terminal wiring does the FP-2010 have?

 

Answer: The FP-2010 has 16–26 AWG copper conductor wire with 7 mm (0.28 in.) of insulation stripped from the end for screw-terminal wiring.

Why Buy From Apex Waves

Apex Waves Youtube Video

"The business transaction was super easy and friendly."


"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"


"They were very helpful to get me the test equipment that I need."


Delivery: UPS, FedEX and DHL – Free FedEx Ground on all orders
Overnight, Next Day Air or Expedited shipping options available
International delivery available
Same day shipping for in-stock on location
Warranty: All of our products are covered by our Apex Waves Warranty.
3 Year Warranty - New Surplus Parts
2 Year Warranty - Refurbished Parts
Returns: No hassle return policy.
Dedicated customer service team.
Payment: Authorize.Net paypal visa card master card american express card BB&T Bank better business bureau
Quick Quotes: Receive Price & Availability Today!
Calibration: Ask About Our Tiered Calibration Levels
Option & Modules: Confirm Your Requirements or Versions
Repair: Cost & Lead Time Available Upon Request for Service
Repair Evaluation: $150
Share this page: facebook twitter linkedIn