SCB-68A
Modular Systems > National Instruments > Accessories
Description: | SCB-68A, 68-Pin Screw Terminal, Shielded I/O Connector Block |
Need an Official Quote?
Or speak to a sales representative for additional information:
National Instruments SCB-68A Shielded I/O Connector Block
The SCB-68A (Part Number: 782536-01) is a Shielded I/O Connector Block. The NI SCB-68A is developed by National Instruments. The SCB-68A is available with the part number 782536-01. This Connector Block delivers a shielded I/O link for interfacing I/O signals to plug-in DAQ devices with a 68-pin male SCSI connector. When the SCB-68A is used with shielded cables, it offers low-noise signal termination. The device is compatible with 68 pin or 100 pin DAQ devices, and its settings can be configured using the Measurement & Automation Explorer (MAX) tool.
Several special features of this Connector Block include a resettable fuse and a magnetic removable lid. The NI SCB-68A can be DIN-Rail mounted, mounted to a panel, or on a desktop. The National Instruments SCB-68A is configured with a general breadboard section for customized circuitry and through hole pads for interchanging electrical components. The through hole pads (0.8 to 0.9 mm in diameter) enable filtering, voltage attenuation, 4 to 20 mA current input measurement, and open thermocouple detection.
The SCB-68A is equipped with a temperature sensor for cold-junction compensation for thermocouples. Switches S1.1 and S1.2 configure the temperature sensor for various analog input settings, while switches S2.1, S2.2, and S2.3 deliver power to the signal conditioning portion of the accessory. The NI SCB-68A performs along-with the shielded cable for low-noise and irregular signal termination functions. The device has a temperature sensor accuracy of ±1.0 °C over a 0 to 70 °C range, a recommended operating temperature range of 0 to 70 °C, and a storage temperature range of –20 to 70 °C.
The National Instruments SCB-68A has a fuse rating of 1.10 A, 8 VDC SMT PTC. The fuse is not user replaceable. The SCB-68A is capable of shuffling of electrical components by using individual circuitry and sockets. The SCB-68A has a 68 screw terminals which contain a wire gauge of 14 to 30 AWG. The SCB-68A requires a power consumption of 1 mA typical without signal conditioning installed and 800 mA maximum from the host computer. The NI device weighs 1 lb, with the dimensions: 5.8 x 5.8 x 1.2 in.
Model | SCB-68A |
---|---|
Manufacturer | National Instruments |
Part Number | 782536-01 |
Type | Shielded I/O Connector Block |
Screw Terminals | 68 |
I/O Connector | One 68-pin male SCSI connector |
CJC Temperature Sensor Accuracy | ±1.0 °C over a 0 to 70 °C range |
Fuse Rating | 1.10 A, 8 VDC SMT PTC |
Weight | 1 lb 7 oz. |
Dimensions | 5.8 × 5.8 × 1.2 in. |
Warranty | Three Year Warranty |
SCB-68A Manual | User Manual and Maintenance Manual Available for Download |
Price | Contact a sales representative for a quote. |
Associated part numbers for the SCB-68A:
153721B-01L, 153721C-01L, 153721D-01L, 153721E-01L, 154137A-01, 200249A-01, 782536-01
National Instruments SCB-68A Frequently Asked Questions
Question: What is the power requirement for the SCB-68A?
Answer: The typical power requirment for the SCB-68A is 1 mA with no signal conditioning installed, while the maximum power is 800 mA from the host computer. While using internal power, the power specs apply to the host computer's power supply; when using external power, the power standards apply to the external source connected at the +5 V screw connection.
Question: What temperature range should the SCB-68A operate in?
Answer: The recommended operating temperature range for the SCB-68A is 0 to 70 °C, while the recommended range for storage is –20 to 70 °C.
Question: Can the SCB-68A be mounted?
Answer: Yes. The SCB-68A can be used on a desktop, or mounted to a panel or standard DIN rail. The SCB-68A has three keyholes on the back for attaching it to a panel or wall.
SCB-68A PDF Manuals
ANALOG OUTPUT SERIES USER MANUAL.PDF
GUIDE DE DC3A9MARRAGE RAPIDE DU NI SCB-68A.PDF
NI 43XX PINOUT LABELS FOR THE SCB-68A NOTE TO USERS.PDF
NI 60XX 60XXE PINOUT LABEL FOR THE SCB-68A.PDF
NI 61XX PINOUT LABEL FOR THE SCB-68A.PDF
NI 62XX 63XX PINOUT LABELS FOR THE SCB-68A NOTE TO USERS.PDF
NI 66XX PINOUT LABELS FOR THE SCB-68A NOTE TO USERS.PDF
NI 67XX PINOUT LABELS FOR THE SCB-68A NOTE TO USERS.PDF
NI 78XXR PINOUT LABELS FOR THE SCB-68A NOTE TO USERS.PDF
NI PXIE 6614 CALIBRATION PROCEDURE.PDF
Why Buy From Apex Waves:
"The business transaction was super easy and friendly."
"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"
"They were very helpful to get me the test equipment that I need."
SCB-68A
Modular Systems > National Instruments > Accessories
1-800-915-6216
- Description
- Technical Specifications
- FAQ
- Manuals & PDFs
National Instruments SCB-68A Shielded I/O Connector Block
The SCB-68A (Part Number: 782536-01) is a Shielded I/O Connector Block. The NI SCB-68A is developed by National Instruments. The SCB-68A is available with the part number 782536-01. This Connector Block delivers a shielded I/O link for interfacing I/O signals to plug-in DAQ devices with a 68-pin male SCSI connector. When the SCB-68A is used with shielded cables, it offers low-noise signal termination. The device is compatible with 68 pin or 100 pin DAQ devices, and its settings can be configured using the Measurement & Automation Explorer (MAX) tool.
Several special features of this Connector Block include a resettable fuse and a magnetic removable lid. The NI SCB-68A can be DIN-Rail mounted, mounted to a panel, or on a desktop. The National Instruments SCB-68A is configured with a general breadboard section for customized circuitry and through hole pads for interchanging electrical components. The through hole pads (0.8 to 0.9 mm in diameter) enable filtering, voltage attenuation, 4 to 20 mA current input measurement, and open thermocouple detection.
The SCB-68A is equipped with a temperature sensor for cold-junction compensation for thermocouples. Switches S1.1 and S1.2 configure the temperature sensor for various analog input settings, while switches S2.1, S2.2, and S2.3 deliver power to the signal conditioning portion of the accessory. The NI SCB-68A performs along-with the shielded cable for low-noise and irregular signal termination functions. The device has a temperature sensor accuracy of ±1.0 °C over a 0 to 70 °C range, a recommended operating temperature range of 0 to 70 °C, and a storage temperature range of –20 to 70 °C.
The National Instruments SCB-68A has a fuse rating of 1.10 A, 8 VDC SMT PTC. The fuse is not user replaceable. The SCB-68A is capable of shuffling of electrical components by using individual circuitry and sockets. The SCB-68A has a 68 screw terminals which contain a wire gauge of 14 to 30 AWG. The SCB-68A requires a power consumption of 1 mA typical without signal conditioning installed and 800 mA maximum from the host computer. The NI device weighs 1 lb, with the dimensions: 5.8 x 5.8 x 1.2 in.
Model | SCB-68A |
---|---|
Manufacturer | National Instruments |
Part Number | 782536-01 |
Type | Shielded I/O Connector Block |
Screw Terminals | 68 |
I/O Connector | One 68-pin male SCSI connector |
CJC Temperature Sensor Accuracy | ±1.0 °C over a 0 to 70 °C range |
Fuse Rating | 1.10 A, 8 VDC SMT PTC |
Weight | 1 lb 7 oz. |
Dimensions | 5.8 × 5.8 × 1.2 in. |
Warranty | Three Year Warranty |
SCB-68A Manual | User Manual and Maintenance Manual Available for Download |
Price | Contact a sales representative for a quote. |
National Instruments SCB-68A Frequently Asked Questions
Question: What is the power requirement for the SCB-68A?
Answer: The typical power requirment for the SCB-68A is 1 mA with no signal conditioning installed, while the maximum power is 800 mA from the host computer. While using internal power, the power specs apply to the host computer's power supply; when using external power, the power standards apply to the external source connected at the +5 V screw connection.
Question: What temperature range should the SCB-68A operate in?
Answer: The recommended operating temperature range for the SCB-68A is 0 to 70 °C, while the recommended range for storage is –20 to 70 °C.
Question: Can the SCB-68A be mounted?
Answer: Yes. The SCB-68A can be used on a desktop, or mounted to a panel or standard DIN rail. The SCB-68A has three keyholes on the back for attaching it to a panel or wall.
SCB-68A PDF Manuals & Diagrams
SCB-68A PDF Manuals
ANALOG OUTPUT SERIES USER MANUAL.PDF
GUIDE DE DC3A9MARRAGE RAPIDE DU NI SCB-68A.PDF
NI 43XX PINOUT LABELS FOR THE SCB-68A NOTE TO USERS.PDF
NI 60XX 60XXE PINOUT LABEL FOR THE SCB-68A.PDF
NI 61XX PINOUT LABEL FOR THE SCB-68A.PDF
NI 62XX 63XX PINOUT LABELS FOR THE SCB-68A NOTE TO USERS.PDF
NI 66XX PINOUT LABELS FOR THE SCB-68A NOTE TO USERS.PDF
NI 67XX PINOUT LABELS FOR THE SCB-68A NOTE TO USERS.PDF
NI 78XXR PINOUT LABELS FOR THE SCB-68A NOTE TO USERS.PDF
NI PXIE 6614 CALIBRATION PROCEDURE.PDF
Why Buy From Apex Waves
"The business transaction was super easy and friendly."
"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"
"They were very helpful to get me the test equipment that I need."