Modular Systems > National Instruments > C Series

NI-9967
NI-9967 alt2
NI-9967 New small
NI-9967 Refurb small

Pictures shown are a representation. Actual item may vary if no part number is provided on quote request.

Same Day Calibration Available

2-3 Year Warranty Included

Free Ground Shipping

Or speak to a sales representative for additional information:

NI-9967 In Stock | Ships Today

NI-9967, Screw Terminal, Strain Relief and Operator Protection Accessory

Rated 4.9/5 | 15 ratings

Please fill out the form below to send in your quote request and a representative will contact you with a formal quote. View blog post on Model Name vs. Part Numbers

+Add more parts

Prefer to send a text message?

Text your name, e-mail, and parts to quote to:   1-919-809-5227

National Instruments NI-9967 Screw Terminal Strain Relief and Operator Protection Accessory (NI-9242 C Series Voltage Input Module accessory)

The NI-9967 (Part Numbers: 783094-01 and 156514A-01 [Rev A or higher]) is a screw terminal strain relief and operator protection accessory made to accommodate the National Instruments NI-9242 (Part Number: 783107-01) 3-Channel, 24-Bit Voltage Input Module. It is a useful and highly recommended accessory for high vibration and/or high voltage applications. The NI-9967 should be used for applications involving a voltage greater than 42.4 Vpk voltage or 60 VDC to earth ground. The NI-9967 connector back shell accessory ensures that the terminals are not accessible to operators.  

The National Instruments NI-9967 screw terminal strain relief and operator protection accessory is a back shell that attaches to the 4-terminal connector on the NI-9242. The NI-9967 assembly can connect single- or three-phase measurement configurations. 

To install the NI-9967 screw terminal strain relief and operator protection accessory, the following wires may be used: 12 AWG to 14 AWG, 16 AWG, and 18 AWG to 24 AWG. The selected wires determine the method of installation. To install the NI-9967 Using 12 AWG to 14 AWG Wire, Route wires under the smallest strain-relief piece. When installing the NI-9967 using the 16 AWG wire, Route wires between the two strain-relief pieces, with the small strain-relief piece on top of the wires and the large strain-relief piece underneath the wires. To install the NI-9967 using the 18 AWG to 24 AWG wire, Route wires under the largest strain-relief piece. Once wires have been properly routed within the assembly, secure the NI-9967 screw terminal strain relief and operator protection accessory pieces in place using screws. 

The NI-9967 is a terminal accessory that ensures potentially hazardous voltages of the NI-9242 are shielded from human contact. The NI-9967 corresponds to the C series analog input modules. The assembly including the NI-9967 offers several channels for measurements between the neutral and signal channels and between the neutral terminal and ground. The NI-9967 screw terminal strain relief and operator protection accessory for signal wire security and high-voltage protection enables safe operation of the NI-9242.

ModelNI-9967
ManufacturerNational Instruments
Part Numbers783094-01, 156514A-01
TypeScrew Terminal Strain Relief and Operator Protection Accessory
Operating Voltage> 42.4 Vpk voltage or 60 VDC to earth ground
Compatible WithNI-9242 Voltage Input Module
Possible AWG Wires for Installation12 AWG to 14 AWG, 16 AWG, and 18 AWG to 24 AWG
ApplicationsHigh Vibration or High Voltage Applications
WarrantyThree Year Warranty
NI-9967 ManualManual and PDFs Available for Download

Associated part numbers for NI-9967:

National Instruments NI-9967 Screw Terminal Strain Relief and Operator Protection Accessory FAQs

 

Question: What applications is the NI-9967 recommended for?

 

Answer: The NI-9967 is highly recommended for use in applications with high vibrations and / or high voltage.

 

Question: How do I install the NI-9967 with the different AWG wires?

 

Answer: The NI-9967 can be installed in the following ways. With the 12 to 14 AWG wire, wires must be routed under the smallest strain-relief piece. With the 16 AWG wire, wires must be routed between the two strain relief pieces, with the smallest on top and the largest underneath. With the 18 to 24 AWG wire, the wires must be routed under the large strain relief piece. 

 

Question: Where does the NI-9967 attach? 

 

Answer: The NI-9967 attaches to the 4-terminal connector on the NI-9242. 

 

Delivery:

UPS, FedEX and DHL – Free Ground on all orders

Overnight, Next Day Air or Expedited shipping options available

International delivery available

Same day shipping for in-stock on location

Warranty:

All of our products are covered by our Apex Waves Warranty.

3 Year Warranty - New Surplus Parts

2 Year Warranty - Refurbished Parts

Returns:

No hassle return policy.

Dedicated customer service team.

Payment:

Authorize.net Visa Master Card American Express BB&T Better Business Bureau Dun & Bradstreet

Quick Quotes:

Receive Price & Availability Today!

Calibration:

Ask About Our Tiered Calibration Levels

Option & Modules:

Confirm Your Requirements or Versions

Repair:

Cost & Lead Time Available Upon Request for Service

Repair Evaluation: $150

Share this page:

Common Typos:

GI-9967, NK-9967, NO-9967, NI-O967, NI-99T7
Why Buy From Apex Waves: