VXI-8340 National Instruments VXI MXI-3 Interface Module | Apex Waves | ImageVXI-8340 NewVXI-8340 | Legacy, Refurbished and New Surplus
VXI-8340 National Instruments VXI MXI-3 Interface Module | Apex Waves | Image
VXI-8340 New
VXI-8340 | Legacy, Refurbished and New Surplus

VXI-8340

4.9/5 | 18 ratings

Modular Systems > National Instruments > MXI-3 Series

Part Number VXI-8340
Manufacturer/Brand National Instruments
Description: VXI-8340, Single or Dual-Port, Copper Cable, VXI MXI-3 Interface Module
Request for Availablility
Fast Quote
Quoted Price
Same Day Calibration Available
2-3 Year Warranty Included
Free Ground Shipping
  Get Pricing

Need an Official Quote?

 

Or speak to a sales representative for additional information:


National Instruments VXI-8340 VXI MXI-3 Interface Module

The VXI-8340 is a VXI MXI-3 Interface Module. The NI VXI-8340 module is manufactured by National Instruments. The VXI-8340 module is designed in two versions: with either a single-port (Part Number: 778293-01) or a dual-port (Part Number: 778293-02). The single-port NI VXI-8340 module is used for connecting directly to a PC, whereas the dual-port VXI-8340 version is used in a system that has a multi-chassis configuration connected in a daisy chain sequence.

The VXI-8340 VXI MXI-3 Interface Module can also be used as a part of the VXI-PCI/PXI8340 interface kit. The NI VXI-PCI/PXI8340 interface kit includes a PCI or PXI module from the NI 8330 series, one VXI-8340 interface module, a cable, and bus interface software. The NI VXI-8340 module is compatible with copper cabling. This VXI MXI-3 Interface Module links an external computer with VXI via MXI-3 technology. The VXI-8340 is a high-performance module due to its ability to combine MITE ASIC with the MXI-3 ASIC. The MITE ASIC is a technology used in the VXI controllers by National Instruments. A PCI-PCI bridge interface is available in the MXI-3 ASIC. This bridge interface is capable of operating at PCI bus full frequency, which is 33 MHz.  

The VXI-8340 VXI MXI-3 Interface Module can be used in a multiple-chassis configuration. The single-port NI VXI-8340 module can only be connected with the controlling PC using a star configuration. In this configuration, each single-port VXI-8340 module is connected to a PC using a direct cable from the VXI-8340 module to the PC. The dual-port NI VXI-8340 module also supports the daisy chain configuration. The dual-port VXI-8340 module incorporates two MXI-3 ports: MXI-in and MXI-out. A cable coming from the PC goes into the MXI-in port, then to the MXI-out port, and lastly the MXI-in port of the next NI VXI-8340 module.

VXI-8340 Obsolete Status has been announced by National Instruments, but the module will still be available for purchase and repairs by Apex Waves.

ModelVXI-8340
ManufacturerNational Instruments
Part Numbers778293-01 and 778293-02
TypeVXI MXI-3 Interface Module
Ports1 or 2
Cable TypeCopper
Maximum Cable Distance10 m
SizeC-size
Dimensions9.2 by 13.4 in.
WeightSingle-port version: 2.6 lb.
Dual-port version: 2.7 lb.
Warranty2-3 Year Warranty
VXI-8340 ManualUser Manual and Maintenance Manual Available for Download
PriceContact a sales representative for a quote.

Associated part numbers for VXI-8340:

187422C-01, 187422C-03, 778293-01, 778293-02

  VXI-8340 PDF Manuals


Why Buy From Apex Waves:

Apex Waves Youtube Video

"The business transaction was super easy and friendly."


"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"


"They were very helpful to get me the test equipment that I need."



Delivery:    
UPS, FedEX and DHL – Free Ground on all orders
Overnight, Next Day Air or Expedited shipping options available
International delivery available
Same day shipping for in-stock on location
Warranty: All of our products are covered by our Apex Waves Warranty.
3 Year Warranty - New Surplus Parts
2 Year Warranty - Refurbished Parts
Returns: No hassle return policy.
Dedicated customer service team.
Payment: Authorize.net Visa Master Card American Express BB&T Better Business Bureau Dun & Bradstreet
Quick Quotes: Receive Price & Availability Today!
Calibration: Ask About Our Tiered Calibration Levels
Option & Modules: Confirm Your Requirements or Versions
Repair: Cost & Lead Time Available Upon Request for Service
Repair Evaluation: $150
Share this page: Facebook Icon Twitter Icon LinkedIn Icon
Common Typos: XI-8340, FXI-8340, VXK-8340, VXI-83R0, VXI-834P

VXI-8340



Modular Systems > National Instruments > MXI-3 Series

VXI-8340
4.9/5 | 18 ratings

VXI-8340, Single or Dual-Port, Copper Cable, VXI MXI-3 Interface Module

Request for Availablility
Same Day Calibration Available
2-3 Year Warranty Included
Free Ground Shipping
  Get Pricing

Call now for best pricing
1-800-915-6216

National Instruments VXI-8340 VXI MXI-3 Interface Module

The VXI-8340 is a VXI MXI-3 Interface Module. The NI VXI-8340 module is manufactured by National Instruments. The VXI-8340 module is designed in two versions: with either a single-port (Part Number: 778293-01) or a dual-port (Part Number: 778293-02). The single-port NI VXI-8340 module is used for connecting directly to a PC, whereas the dual-port VXI-8340 version is used in a system that has a multi-chassis configuration connected in a daisy chain sequence.

The VXI-8340 VXI MXI-3 Interface Module can also be used as a part of the VXI-PCI/PXI8340 interface kit. The NI VXI-PCI/PXI8340 interface kit includes a PCI or PXI module from the NI 8330 series, one VXI-8340 interface module, a cable, and bus interface software. The NI VXI-8340 module is compatible with copper cabling. This VXI MXI-3 Interface Module links an external computer with VXI via MXI-3 technology. The VXI-8340 is a high-performance module due to its ability to combine MITE ASIC with the MXI-3 ASIC. The MITE ASIC is a technology used in the VXI controllers by National Instruments. A PCI-PCI bridge interface is available in the MXI-3 ASIC. This bridge interface is capable of operating at PCI bus full frequency, which is 33 MHz.  

The VXI-8340 VXI MXI-3 Interface Module can be used in a multiple-chassis configuration. The single-port NI VXI-8340 module can only be connected with the controlling PC using a star configuration. In this configuration, each single-port VXI-8340 module is connected to a PC using a direct cable from the VXI-8340 module to the PC. The dual-port NI VXI-8340 module also supports the daisy chain configuration. The dual-port VXI-8340 module incorporates two MXI-3 ports: MXI-in and MXI-out. A cable coming from the PC goes into the MXI-in port, then to the MXI-out port, and lastly the MXI-in port of the next NI VXI-8340 module.

VXI-8340 Obsolete Status has been announced by National Instruments, but the module will still be available for purchase and repairs by Apex Waves.

ModelVXI-8340
ManufacturerNational Instruments
Part Numbers778293-01 and 778293-02
TypeVXI MXI-3 Interface Module
Ports1 or 2
Cable TypeCopper
Maximum Cable Distance10 m
SizeC-size
Dimensions9.2 by 13.4 in.
WeightSingle-port version: 2.6 lb.
Dual-port version: 2.7 lb.
Warranty2-3 Year Warranty
VXI-8340 ManualUser Manual and Maintenance Manual Available for Download
PriceContact a sales representative for a quote.

Why Buy From Apex Waves

Apex Waves Youtube Video

"The business transaction was super easy and friendly."


"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"


"They were very helpful to get me the test equipment that I need."


Delivery: UPS, FedEX and DHL – Free FedEx Ground on all orders
Overnight, Next Day Air or Expedited shipping options available
International delivery available
Same day shipping for in-stock on location
Warranty: All of our products are covered by our Apex Waves Warranty.
3 Year Warranty - New Surplus Parts
2 Year Warranty - Refurbished Parts
Returns: No hassle return policy.
Dedicated customer service team.
Payment: Authorize.Net paypal visa card master card american express card BB&T Bank better business bureau
Quick Quotes: Receive Price & Availability Today!
Calibration: Ask About Our Tiered Calibration Levels
Option & Modules: Confirm Your Requirements or Versions
Repair: Cost & Lead Time Available Upon Request for Service
Repair Evaluation: $150
Share this page: facebook twitter linkedIn