Modular Systems > National Instruments > R Series
Or speak to a sales representative for additional information:
PXIe-5170R Request for Availablility
PXIe-5170R, 4 or 8 Channel, 14 bits, PXI Oscilloscope
Need an Official Quote?
National Instruments PXIe-5170R PXI Oscilloscope
The PXIe-5170R (Part Numbers: 783690-01 and 783691-01) is a reconfigurable PXI Oscilloscope. Since there are two part numbers for this oscilloscope, there are several differences between the two versions. Part number 783690-01 has 4 voltage input channels and 750 MB onboard memory. Part number 783691-01 has 8 voltage input channels and 1.5 GB onboard memory. The PXIe-5170R is launched by National Instruments. The “R” in the NI PXIe-5170R Oscilloscope represents the reconfigurable feature of the PXIe-5170R. The NI PXIe-5170R is built for PXI Express systems. The PXIe-5170R can be programmed with the NI-SCOPE instrument driver by NI.
The National Instruments PXIe-5170R PXI Oscilloscope is assembled with a reconfigurable Kintex-7 325T FPGA. The NI PXIe-5170R Oscilloscope comes with a maximum oscilloscope bandwidth of 100 MHz. The PXIe-5170R utilizes SMA connectors. The NI PXIe-5170R functions with DC input coupling. The analog input impedance of 50 Ω is available in the PXIe-5170R. The NI PXIe-5170R includes many triggering modes as well.
The NI PXIe-5170R PXI Oscilloscope comes with a maximum sampling rate of 250 MS/s. The National Instruments PXIe-5170R is developed for the synchronization of advanced PXI chassis. The PXIe-5170R functions with a maximum current of 200 mA and an analog input resolution of 14 bits. The NI PXIe-5170R PXI Oscilloscope has an analog input voltage range from -2.5 V to 2.5 V. The PXIe-5170R can be used within an operating temperature of 0 to 40 °C. The NI PXIe-5170R can be used with a maximum power of 28.25 W.
Model | PXIe-5170R |
---|---|
Manufacturer | National Instruments |
Part Numbers | 783690-01 and 783691-01 |
Type | PXI Oscilloscope |
Maximum Bandwidth | 100 MHz |
FPGA Type | Kintex-7 325T |
Voltage Input Channels | 4 or 8 |
Maximum Sample Rate | 250 MS/s |
Dimensions | 7.3 in. × 0.8 in. × 5.1 in. |
Weight | 4-Channel version: 16.3 oz. 8-Channel version: 17.1 oz. |
Warranty | 2-3 Year Warranty |
PXIe-5170R Manual | User Manual and Maintenance Manual Available for Download |
Price | Contact a sales representative for a quote. |
Driver Downloads for PXIe-5170R
OS Compatibility:
Win XP 32-bit, Win 7 32-bit, Win 10 32-bit
Why Buy From Apex Waves:
"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"
"They were very helpful to get me the test equipment that I need."
PXIe-5170R
Modular Systems > National Instruments > R Series
PXIe-5170R, 4 or 8 Channel, 14 bits, PXI Oscilloscope
1-800-915-6216
- Description
- Technical Specifications
- Drivers
National Instruments PXIe-5170R PXI Oscilloscope
The PXIe-5170R (Part Numbers: 783690-01 and 783691-01) is a reconfigurable PXI Oscilloscope. Since there are two part numbers for this oscilloscope, there are several differences between the two versions. Part number 783690-01 has 4 voltage input channels and 750 MB onboard memory. Part number 783691-01 has 8 voltage input channels and 1.5 GB onboard memory. The PXIe-5170R is launched by National Instruments. The “R” in the NI PXIe-5170R Oscilloscope represents the reconfigurable feature of the PXIe-5170R. The NI PXIe-5170R is built for PXI Express systems. The PXIe-5170R can be programmed with the NI-SCOPE instrument driver by NI.
The National Instruments PXIe-5170R PXI Oscilloscope is assembled with a reconfigurable Kintex-7 325T FPGA. The NI PXIe-5170R Oscilloscope comes with a maximum oscilloscope bandwidth of 100 MHz. The PXIe-5170R utilizes SMA connectors. The NI PXIe-5170R functions with DC input coupling. The analog input impedance of 50 Ω is available in the PXIe-5170R. The NI PXIe-5170R includes many triggering modes as well.
The NI PXIe-5170R PXI Oscilloscope comes with a maximum sampling rate of 250 MS/s. The National Instruments PXIe-5170R is developed for the synchronization of advanced PXI chassis. The PXIe-5170R functions with a maximum current of 200 mA and an analog input resolution of 14 bits. The NI PXIe-5170R PXI Oscilloscope has an analog input voltage range from -2.5 V to 2.5 V. The PXIe-5170R can be used within an operating temperature of 0 to 40 °C. The NI PXIe-5170R can be used with a maximum power of 28.25 W.
Model | PXIe-5170R |
---|---|
Manufacturer | National Instruments |
Part Numbers | 783690-01 and 783691-01 |
Type | PXI Oscilloscope |
Maximum Bandwidth | 100 MHz |
FPGA Type | Kintex-7 325T |
Voltage Input Channels | 4 or 8 |
Maximum Sample Rate | 250 MS/s |
Dimensions | 7.3 in. × 0.8 in. × 5.1 in. |
Weight | 4-Channel version: 16.3 oz. 8-Channel version: 17.1 oz. |
Warranty | 2-3 Year Warranty |
PXIe-5170R Manual | User Manual and Maintenance Manual Available for Download |
Price | Contact a sales representative for a quote. |
Why Buy From Apex Waves
"The business transaction was super easy and friendly."
"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"
"They were very helpful to get me the test equipment that I need."